Runxin Runlucky RL-Q01 User manual

User Manual for High-efficiency Automatic Backwash Disk Prefilter
0WRX.466.671
1. Main Application
Used for filtering municipal water treatment. Coarse filtration. Can filter PM
larger than 0.05mm, for protecting the back water equipment. Suitable for
installation in house.
2. Product Characteristics
3. Technical Parameters
Note: Rated treated water quantity is related to raw water quality, the more grain particles
containing, the less water quantity will be.
4. Check the Spare Parts
When unpacking the product, please check below spare parts.

5. Product Appearance and Installation Dimensions
Remark: M: male thread, all dimensions above are in mm.
6. Installation Notes
1. Installation conditions should conform to the requirements of the product work
environment.
2. It should be installed after water meter, but in front of other equipment.
3. It should stay away from hydrops, no exposure to rain or sunlight.
4. If pipeline pressure change suddenly, please install regulator valve.
5. The installation position of drain should lower than product’s position. (Figure at right).
6. The distance between installation location and power socket should shorter than power
line.
7. Please avoid subsurface pipe when drilling during the installation of screw.
8. If you have any questions, please feel free to contact our after-sales service or
professionals.

7. Installation Step
Before installation, be sure all these tools and materials listed below are ready:
Electronic hand drill 1 piece (matching with Φ6 masonry drill and tile drill, each 1 piece),
cross screwdriver 1 piece, hammer 1 piece, pipeline clamp several pieces, thread seal
tape several pieces.
8. Operation and Setting
1. Display
a) Under service position, figure 1A, 1B, 1C display circularly 10 seconds.
b) Under service position, figure 1A displays residual water (For example: L02.0:
residual water 02.0m3.L00.0: start to backwash at next 2am).
c) Under service position, figure 1B displays the current flow rate (15: the current flow
rate is 15L/min).
d) Figure 1C displays the current time.
2. Lock and unlock

Without any key operation in one minute, interface will be locked. (Refer to Figure 2A)
Press“ ” and “ ” at the same time for 5 seconds, the interface will be unlocked.
3. Manual function
a) Manual backwash (backwash by manual operation when needed)
In the status of unlock, figure“ ” (Figure 3A), enter into backwash (Figure 3B),
backwash time is 20 seconds, after finished, entered into service automatically. In the
process of backwash, figure “ ”, it will back to service.
a) Turn off (when maintaining filter or other water appliance products, you can cut off
the water by manual operation).
In the status of unlock, figure “ ” for 5 seconds, valve cut off the water, (Figure 4A). The
status of close refer to figure 4B. Figure “ ” for 5 seconds again back to service.
4. Parameter Setting (All the setting should in the status of unlock)
a) Set the current time (Figure 5A, 5B, 5C, 5D, 5E, 5F. Set the current time from 14:15 to
15:05)

b) Set the water capacity(Figure 6A,6B,6C,6D,6E. Set the water capacity from 0.8m³to
0.3 m³.)When the water capacity reaches the set value, starts to backwash at next
2am.Set range: 0~20.0m³.
c) Set the closing time of continuous water supplying (Figure 7A, 7B, 7C, 7D, 7E.Set
continuous water supplying time from 10 min to 20 min.)When the continuous outlet
reaches the set value, may forget to turn off the faucet or occurs pipeline leakage, so the
valve will cut off the water. Set range 0~90 min.0 means this function invalid. User can
set it according to family water usage patterns.

d) Set peak flow rate. (Figure 8A, 8B, 8C, 8D, 8E.Set peak flow rate from 20 L∕min to 10 L
/min.)When the current flow rate is higher than setting rate, it will cut off water supplying.
Set range10~90L/min.
e) Set maximal interval regeneration days.(Figure 9A, 9B, 9C, 9D, 9E. Set the maximal
interval regeneration days from 10 days to 15 days.)When the water supply days reach
the setting value, it still will backwash at next 2am to avoid impurities blocked caused by
nonwashing for a long time.

5. LED lamp (Refer to Figure 10)
Touch any button, the LED lamp will light for 5 minutes. Without any operation in 5
minutes, the light will be off.
9. Maintenance (suggested once a year)
Steps:
After clean, repeated above steps backward to assemble all the parts and check its seal
for later use.
10. Trouble-Shooting

Problem
Cause
Correction
-E1-
1. Motor damaged
2. Wire of motor with controller is
loose
3. Locating board damaged
4. Wire of locating board with.
Controller is loose
5. Small gear damaged
1. Replace motor
2. Reconnect wire of
motor.
3. Replace locating board.
4. Reconnect wire of
locating board.
5. Replace small gear.
-E2-
1. Locating board damaged
2. Display board damaged
1. Replace locating board.
2. Replace display board.
-E3-
1. Display board damaged
1.Replace display board
-E4-
1. Display board damaged
1.Replace display board
Current flow
rate “0”
1. Wire of water meter
disconnect or breakdown.
2. Wire of water meter damaged.
3. Turbine gets stuck.
4. Other causes
1. Reconnect wire of
water meter.
2. Replace wire of water
meter.
3. Clean turbine.
4. Replace turbine.
Outlet flow
rate decrease
1. Impurities stuck in filter
cartridge.
2. Filter net in the filter cartridge
gets stuck.
1. Backwash manual.
2. Clean filter net.
Ineffective
backwash
1. Inlet water pressure is low.
2. Fixed seat of filter cartridge
gets stuck.
1. Install booster pump or
increase flow.
2. Disassemble and clean
the filter cartridge.
-OFF-
1. Setting peak flow rate is too
small.
2. Setting closing time for.
Continuous water supplying is
too short.
3. Forget to turn off the faucet or
pipeline burst.
1. Reset peak flow rate,
according to the flow rate.
2. Reset closing time for
continuous water
supplying according to
water usage.
3. Check and repair the
pipeline.
11. Warranty Card
Dear client:
This warranty card is the guarantee proof of RUNLUCKY brand High-efficiency
Automatic Backwash Disk Prefilter. It is kept by clientitself, you could get the after-sales
services from the supplier which is appointed by RUNXIN manufacturer. Please keep it
properly. It couldn’t retrieved if lost. It couldn’t be repaired free of charge under the below
conditions:
1. Guarantee period expired. (One year).
2. Damage resulting from using, maintenance, and keeping that are not in accordance
with the instruction.
3. Damage resulting from repairing not by the appointed maintenance personnel.

4. Content in guarantee proof is unconfirmed with the label on the real good or be altered.
5. Damage resulting from force majeure.
When product need warranty service, please fill the form and send this card together with
the product to the appointed suppliers or RUNXIN Company.
This manual suits for next models
1
Other Runxin Water Dispenser manuals