Safe Fleet LMU Controller User manual

© Safe Fleet | March 2019 | All rights reserved | Part #: 700-1132 R3
For LMU Models 26 and 27
LMU Controller
Installation Guide

© Safe Fleet | March 2019 | All rights reserved | Part #: 700-1132 R3
— THIS PAGE LEFT INTENTIONALLY BLANK —

LMU Controller
Table of Contents
© Safe Fleet | March 2019 | All rights reserved | Part #: 700-1132 R3
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Kit Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Complete Installation Record.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Install LMU Controller Antenna. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Install LMU Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
LMU Controller LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Operation Status.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Set Up LMU Controller in vMax Live Plus.. . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Login and Launch.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Troubleshooting.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Specications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Customer Service.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Product Information.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Warranty And End-User License Agreement.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

LMU Controller
© Safe Fleet | March 2019 | All rights reserved | Part #: 700-1132 R3p. 4
Overview
Use this guide to install and set up the Location Messaging Units LMU 26 and LMU 27 Controller.
The LMU Controller provides vehicle tracking to view in vMax Live Plus 5.0 for users on Sprint, Verizon, and Rogers cell
networks.
This guide provides instruction for installing the LMU Controller by itself or with a DVR. To work with a DVR, the DVR needs
to have rmware version 2.0 or higher.
This installation must be performed by a professional with approval from Seon Design.
Overview
The required and optional contents of a typical installation package are shown below. The actual contents of your installation
package may vary, depending on the options selected.
• 20 pin cable, including power harness and
fuses
• Quick Install Guide
• LMU Controller
Kit Contents
• Alarm Button with extension cable and 4
crimps
• Antenna (GPS/Cellular)
• GPS extension cable (optional, with DVR
install)
• Aux1 to GPS adaptor cable (optional, with DVR
install)

LMU Controller
© Safe Fleet | March 2019 | All rights reserved | Part #: 700-1132 R3p. 5
Installation
1. From Seon or the customer, the installer gets an Installation
Record (see sample below) with the Device ID column populated.
The Device ID is the 10 digit ESN number on the LMU Controller
label.
2. Fill in the rest of the Installation Record elds for the bus
installation
Installation
Complete Installation Record

LMU Controller
© Safe Fleet | March 2019 | All rights reserved | Part #: 700-1132 R3p. 6
Installation
Install LMU Controller Antenna
1. Identify a suitable location for the antenna on the inside of the windscreen.
The antenna must be installed on the inside of the front windshield out of the way of the driver’s view.
The 10 foot antenna cables attach to the LMU Controller’s GPS and Cellular antenna connectors.
IMPORTANT
• The antenna cable length is 10 feet long and cannot be extended. This may limit the location options for
the LMU Controller.
• Use only the supplied antenna. Antennas from other manufacturers will not work with the LMU Controller.
2. Using the supplied alcohol wipe pad, clean the window surface where the antenna will be installed.
3. Peel the protective cover from the foam backing on antenna.
4. Be careful not to touch or allow any foreign material to come in contact with the exposed adhesive.
5. Attach the antenna to the window.
• Do not attach within the wiper sweep area.
• Do not attach to windows that can open.
6. Run the cables to the intended LMU Controller location.

LMU Controller
© Safe Fleet | March 2019 | All rights reserved | Part #: 700-1132 R3p. 7
Installation
Install LMU Controller
1. Select an LMU Controller modem installation location that meets the following requirements:
CAUTION: Installation Requirements
• The LMU Controller must be installed within the range of the Antenna cable distance.
• Install within the vehicle, close to the DVR if possible.
• Install where LEDs can be seen if necessary.
• Install in the front of the vehicle.
• Route the wiring and cables away from sharp edges that might damage the insulation.
• Avoid sharp bends in the cable.
Installation Requirements
Location Choose a dry location with easy access to the electrical panel and cable connections to mount the
LMU Controller.
Check that the LMU Controller location is within the maximum reach of the antenna cable.
Install the LMU Controller away from any place where tampering with the device or cable connections
may occur.
Surface Do not mount the LMU Controller to a plastic panel or other surface that is subject to constant
vibration.
Clearance Allow sufcient clearance of at least six (6) inches in front of the LMU Controller and two (2) inches
on each side for easy access and removal of cable connectors and ports.
Allow sufcient clearance behind the LMU Controller for antenna and power cables.
Harnesses Provide enough slack on the power cable to prevent any force from being exerted on the connectors.
A single 4-inch diameter loop is sufcient.
2. Using the supplied alcohol wipe pad, clean the vehicle surface where the LMU Controller will be installed.
3. Peel the protective cover from the velcro backing on the LMU Controller. Be careful not to touch or allow any foreign
material to come in contact with the exposed adhesive.
4. Attach the LMU Controller to the vehicle.
5. Connect all power, alarm, GPS, and Stop Arm cabling to the LMU Controller 20 pin harness using the following
diagram.

LMU Controller
© Safe Fleet | March 2019 | All rights reserved | Part #: 700-1132 R3p. 8
Installation
3 wires
3A Battery Negative (black)
Vehicle + 12/24V (red)
Black wire from pin 16 to black on
extension cable and Alarm button.
Aux 1
Cable Harness
and Connector
TL/TX/TH/NH16
GPS socket
LMU Controller Connections
Typical System Setup, with optional DVR Connections
Ignition (white)
3A
LMU
to GPS
Adaptor
Cable
Power harness (red, black, white wires)
LMU Controller, Harness LED end
Comm LED
GPS LED
1x5 Microt
connector
2x2 Microt
connector
To
DVR
option
Pin 1
Pin 11
Pin 10
Pin 20
NOTE: Aux 2 connector
and other harness
wires not mentioned
here are not used.
GPS4 Cable
Pin 16 Alarm Button
(black wire, active low)
Pin 3 Stop Arm
(blue wire, active high)
3.5 mm
GPS
Connector
GPS &
Cellular
Antenna
LMU Controller, Antenna end
2.5 mm
Comm
Connector
MX/DX:
GPS socket
on Smart-Link
Orange wire from pin 12 to red on
extension cable and Alarm button.
Pin 12 Alarm Button
(orange wire, active low)
6. Clip the 1x2 Microt connector from the end of the alarm button extension cable.
7. Connect the alarm button’s red and black wires to the extension cable’s red and black wires with the supplied crimps.
8. If the LMU Controller is being connected to a DVR, connect the AUX 1 connector from the LMU Controller 20 pin
harness to the supplied 060-1012 adapter cable, which connects to the GPS Extension cable, which connects to the
DVR’s GPS socket.
IMPORTANT
If the DVR has a GPS4 unit installed, the GPS4 unit can be removed. The LMU Controller replaces GPS4
functionality on the DVR.

LMU Controller
© Safe Fleet | March 2019 | All rights reserved | Part #: 700-1132 R3p. 9
LMU Controller LEDs
9. Run the harness cabling and the GPS and Cellular cabling to the intended LMU Controller location.
10. Connect the GPS and Cellular connectors to the LMU Controller.
11. Connect the 20 pin harness to the LMU Controller.
12. Tie off unused wires from harness.
LMU Controller LEDs
Operation Status
Once the 20 pin harness is connected to the LMU Controller, this will have power.
The LMU Controller is congured to provide vehicle tracking and live video streaming information to vMax Live Plus users.
LEDs on the LMU Controller indicate operation status and display operation mode conditions as described below.
LED Status Indicators
Comm LED - Orange Condition GPS LED - Green Condition
Off Modem Off Off GPS Off
Slow Blinking Comm On - Searching Slow Blinking GPS On
Fast Blinking Network Available Fast Blinking GPS Time Sync
Fast Blink to Solid Registered - no Inbound Acknowledgment Solid GPS Fix
Solid Registered - Inbound Acknowledgment

LMU Controller
© Safe Fleet | March 2019 | All rights reserved | Part #: 700-1132 R3p. 10
Set Up LMU Controller in vMax Live Plus
Set Up LMU Controller in vMax Live Plus
Login and Launch
On the installation record, nd the provided Fleet ID, username (default: admin), and password (default: password) to log
into www.vmaxlive.net.
a. Enter your Fleet ID (provided by Seon).
b. Click Continue. If conrmed, a similar User and
Password window appears.
c. Enter your User ID and your Password.
d. Click Login.
TO SET UP THE DVR AND LMU CONTROLLER
1. In vMax Live Plus, in the main view, click Integrations.
CAUTION: Password Security
The default password is “password”. For security purposes, Seon recommends that the user default login and
system settings passwords should be changed. Seon is not responsible if the password is lost or forgotten.

LMU Controller
© Safe Fleet | March 2019 | All rights reserved | Part #: 700-1132 R3p. 11
Set Up LMU Controller in vMax Live Plus
2. When the Integrations module opens, access Asset Collections and click New.
3. When the Asset Collection Details display:
i. Select an existing Vehicle ID from the drop-down menu.
ii. Enter any additional Notes in the corresponding text-box.
iii. Select the Seon Integration Account.
iv. Select the Device ID that corresponds to the LMU your are installing.
v. Click Add. The Device ID and Integration Account will be disclosed in the table.
vi. Click Save.

LMU Controller
© Safe Fleet | March 2019 | All rights reserved | Part #: 700-1132 R3p. 12
Set Up LMU Controller in vMax Live Plus
NOTE: Missing Device ID
If the Device ID your are looking for does not display in the drop-down menu, contact tech support. Please nd
contact information at the end of this guide.
NOTE: Synchronize Button
Zonar Account users might need to click the Synchornize button if the Device ID does not display in the drop-down
menu. This action will update the available Zonar devices. The Synchronize button is not meant for Seon Account
users.
ADDING A NEW VEHICLE
If you need to add a new vehicle:
1. Click Add next to the Vehicle ID drop-down menu (see previous image). The Vehicle Details window opens.
2. Fill in the Vehicle Details:
i. Enter a Vehicle ID.
ii. Select a Vehicle Type.
iii. Select a Vehicle Group.
iv. Click Save.

LMU Controller
© Safe Fleet | March 2019 | All rights reserved | Part #: 700-1132 R3p. 13
Troubleshooting
Troubleshooting
This section provides information and procedures for troubleshooting the LMU Controller interface and the vMax Live Plus
software.
Troubleshooting
Symptom Possible Cause Solution
LMU Controller will not start The power cabling may not be
completely connected.
Check cabling connections.
LMU Controller is not detected by
vMax Live Plus
The GPS sensor cannot detect the
satellites.
Move the vehicle out of garage.
The cellular connection is not
complete.
Check with Seon Technical Support.
LMU Controller LEDs are on up to 15
minutes after ignition off.
The LMU Controller is factory set to have a power off delay of 15 minutes to
allow for cellular transmission delays in communicating vehicle activity after the
vehicle reaches the yard and powers down.

LMU Controller
© Safe Fleet | March 2019 | All rights reserved | Part #: 700-1132 R3p. 14
Specications
Specications
System Information LMU 26 LMU 27
Cellular LT E CDMA (Sprint/Verizon)
GPS 56 channel (with SBAS, WAAS, EGNOS, MSAS,
GAGAN) GPS Receiver
2m CEP
-162 dBm tracking sensitivity
50 channel (with SBAS, DGPS) GPS Receiver
2m CEP (with SA off)
-160 dBm tracking sensitivity
Frequency Bands Quad band Class 12 GPRS Modem
Standards LTE CAT-1 packet data, SMS, UDP, and TCP CDMA 1xRTT packet data, UDP and SMS
Connectors
GPS Antenna 50 ohm SMA (female connector) 50 ohm SMA (female connector)
GMS Antenna 50 ohm SMC (female connector) 50 ohm SMC (female connector)
Power/Signals 20 pin Micro Fit (female connector) 20 pin Micro Fit (female connector)
Environment
Operating Temperature -22°F to 167°F
-30°C to 75°C
-22°F to 167°F
-30°C to 75°C
Storage Temperature -40°F to 185°F
-40°C to 85°C
-40°F to 185°F
-40°C to 85°C
Humidity RH 95% @ 50°C non-condensing RH 0% to 95% non-condensing
Certication
EMC FCC, SAE J1113 FCC Part 15B, SAE J1113 Parts 2, 12, 21, and 41
Electrical
Power Source 7-32VDC 6-32 VDC
Power Consumption Max 100mA at 12VDC 100mA at 12VDC
Power Consumption Typical 70mA at 12VDC 70mA at 12VDC
POwer Consumption Sleep 3mA at 12VDC 3mA at 12VDC
IMPORTANT:
Specications are subject to change without notice.

LMU Controller
© Safe Fleet | March 2019 | All rights reserved | Part #: 700-1132 R3p. 15
Appendix
Customer Service
Technical Support: 1-844-899-7366
General Enquiries: 1-877-630-7366
Warranty And End-User License Agreement
Product Information
Complete warranty details are available at https://www.seon.com/documents/Seon-Warranty.pdf
For product information and documentation, please visit https://community.seon.com.
Please contact Technical Support if you do not have access credentials.
Appendix
Table of contents
Other Safe Fleet Controllers manuals