Wireless Indoor
PIR Motion Detector
Model STI-34701
Safety Technology International, Inc.
“We Protect The Things That Protect You.”
Features:
· APYROFLEX™ IR sensor and Highbar™ signal processing for superior
performance.
· 44 ft. range and 90 degree field of view (45 degrees to each side).
· Mountable on flat-wall or 45 degree corner.
· Cover tamper.
· Strong, reliable RF signal.
· 6-8 year battery life of CR123A battery.
· Low Battery indication.
Program
sensor before
installation
Warranty Information:
Safety Technology International, Inc.
2306 Airport Rd • Waterford, MI 48327
Phone: 248-673-9898 • Fax: 248-673-1246
[email protected] • www.sti-usa.com
Safety Technology International (Europe) Ltd.
Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch
Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999
Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (UK only)
E-mail: info@sti-europe.com • Web: www.sti-europe.com
Inst. 34701 JAN2013
Printed in USA
Safety Technology International, Inc. warrants to the original consumer/purchaser what
this product shall be free of defects in material and workmanship under normal use and
circumstances for a period of one (1) year from the original date of purchase.
Important Notice:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
This device may not cause harmful interference.
This device must accept any interference that may be received, including interference
that may cause undesired operation.
Changes or modifications not expressly approved by STI could void the user’s authority to
operate this equipment.
This product meets the applicable industry Canada Technical specifications.
Le Présent matériel est conforme aux spécifications techniques applicables d’Industrie Canada.
Model: 34701 FCC ID: TXL34701 IC: 6335A-34701
Technical Support:
Contact STI at 800-888-4784 ext. 202
Additional Wireless Alert Series Products:
STI-34099 Single Channel Slave Receiver
STI-34104 4-Channel Receiver
STI-V34104 4-Channel Voice Receiver
STI-34108 8-Channel Receiver
STI-34188 8-Zone Relay Board
STI-34101 Solar Powered Driveway Monitor Sensor
STI-34151 Battery Powered Driveway Monitor Sensor
STI-34201 Wireless Mailbox Alert Sensor
STI-34301 Wireless Garage Sentry Sensor
STI-34401 Wireless Universal Alert Sensor
STI-34501 Wireless Pool Alert Sensor
STI-34601 Wireless Doorbell Button
STI-34701 Indoor Wireless PIR
STI-34751 Outdoor Wireless PIR
STI-6200WIR Wireless Fire Extinguisher Theft Stopper
STI-6200WIR4 Wireless Fire Extinguisher Theft Stopper w/Receiver
STI-6400WIR Wireless Exit Stopper Door Alarm
STI-6400WIR4 Wireless Exit Stopper Door Alarm with Receiver
STI-6517A Stopper Station Shield with Sound
STI-6517B Stopper Station Shield with Sound and Transmitter
STI-30104 Lamp Controller
STI-30105 Extended Antenna
STI-34105 Voltamax 12VDC (500mA) Power Supply
STI-34106 Keyfob
STI-34109 Repeater
All manuals and user guides at all-guides.com
-2- -3-
Programming Instructions:
1. Remove cover by releasing snap closure located at the bottom center.
2. Put receiver in program mode (refer to receiver instructions for programming).
3. Remove Mylar tab from battery. Unit should immediately program into receiver, if not
press the tamper switch.
4. Motion sensitivity:
· Normal sensitivity: jumper on BOTH PINS
· High sensitivity: remove jumper
Mounting Instructions:
1. Release holding tab and remove PCB (see internal view for tab location).
2. Remove screw knockouts for mounting.
3. Replace PCB. Make sure bug / insulation foam is installed.
4. Mount at 7.5ft (ideal height) with provided screws and optional anchors.
5. Replace cover. Unit immediately goes into 3 minute walk test. To reset walk test, remove
cover and reattach.
Walk Test LED:
1. LED lights for 3 minutes when motion sensed (only during walk test).
2. Wireless transmissions are sent for each detection; so walk test can be used for receiver
test as well.
3. Motion stops (locks out) sensing for 20 seconds after LED flashes.
4. When complete, replace cover fixing screw.
Operation:
1. Motion stops (locks out) transmitting wireless sensor alarms for 3 minutes after
sending an alarm transmission. This is to conserve battery life.
2. Walk Test LED does not activate in normal operating mode, only works during walk test.
3. Tamper: when cover is opened.
4. Supervisory: every hour.
Specifications:
· Mounting Hardware: #6 screw
· Mounting Height: 7.5ft (ideal height)
· Replacement battery: CR123A 1500mAH
· Temperature range: 0°F to 120°F
· Housing dimensions: 3.7” X 2.37” X 1.65”
Specifications subject to change without notice.
Side View
7.5 ft.
010 ft 20 ft 30 ft 40 ft
LOCK DOWN SHORT RANGE MIDDLE RANGE LONG RANGE
0
44 ft
44 ft
44 ft
Top View
BUG FOAM
BATTERY
+
PCB HOLDING TAB
WALK TEST LED
TAMPER AND WALK TEST SWITCH
MOTION SENSOR
SENSITIVITY JUMPER
MYLAR TAB
All manuals and user guides at all-guides.com

Other Safety Technology International Security Sensor manuals

Safety Technology International 34701 User manual

Safety Technology International

Safety Technology International 34701 User manual

Safety Technology International STI-7535MED Original operating instructions

Safety Technology International

Safety Technology International STI-7535MED Original operating instructions

Safety Technology International Exit Stopper STI-6400 Series Instructions for use

Safety Technology International

Safety Technology International Exit Stopper STI-6400 Series Instructions for use

Safety Technology International STI-34752 User manual

Safety Technology International

Safety Technology International STI-34752 User manual

Safety Technology International STI-6400 Exit Stopper User manual

Safety Technology International

Safety Technology International STI-6400 Exit Stopper User manual

Safety Technology International STI-34701 User manual

Safety Technology International

Safety Technology International STI-34701 User manual

Popular Security Sensor manuals by other brands

Trotec BE17 operating manual

Trotec

Trotec BE17 operating manual

Toshiba LF664 instruction manual

Toshiba

Toshiba LF664 instruction manual

THORLABS DET100A user guide

THORLABS

THORLABS DET100A user guide

Risco iWISE QUAD AM Grade 3 installation instructions

Risco

Risco iWISE QUAD AM Grade 3 installation instructions

BW Technologies GasAlertMax user manual

BW Technologies

BW Technologies GasAlertMax user manual

STEINEL PROFESSIONAL IS 3360 Information

STEINEL PROFESSIONAL

STEINEL PROFESSIONAL IS 3360 Information

Ekinex EK-SM2-TP manual

Ekinex

Ekinex EK-SM2-TP manual

Theben thePixa P360 KNX UP WH manual

Theben

Theben thePixa P360 KNX UP WH manual

Besam SR221-2 quick start guide

Besam

Besam SR221-2 quick start guide

Homesafe 135 plus Operation instructions

Homesafe

Homesafe 135 plus Operation instructions

LACO Technologies TITAN VERSA C Operation and maintenance manual

LACO Technologies

LACO Technologies TITAN VERSA C Operation and maintenance manual

clare ClareOne CLR-C1-CO Installation sheet

clare

clare ClareOne CLR-C1-CO Installation sheet

Mircom MIX-2351TAP Installation and maintenance instructions

Mircom

Mircom MIX-2351TAP Installation and maintenance instructions

Popp POPE701202 manual

Popp

Popp POPE701202 manual

STEINEL Professional IS 180 digi HD manual

STEINEL

STEINEL Professional IS 180 digi HD manual

Lince BOBBY-AM Installation, operation and maintenance manual

Lince

Lince BOBBY-AM Installation, operation and maintenance manual

3M SD-200 manual

3M

3M SD-200 manual

SharpEye 40 user guide

SharpEye

SharpEye 40 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.