Safety Vision TOTALVIEW HD User manual

TOTALVIEW HD
USER GUIDE

Important Notices
Title: TOTALVIEW HD User Guide
Document Version: 1
Revision: 0
Safety Vision attempts to provide information contained
in this manual based on the latest product information
available at the time of publication. However, because of
Safety Vision’s policy of continual product improvement,
Safety Vision reserves the right to amend the information
in this document at any time without prior notice.
This material is condential and the property of Safety
Vision. It is shared with your company for the sole purpose of
helping you with the operation of the described equipment.
Safety Vision makes no warranty of any kind with
regard to this material, including, but not limited to,
the implied warranties of merchantability and tness
for a particular purpose. Safety Vision shall not be
liable for errors contained herein or for incidental
or consequential damages in connection with the
furnishing, performance, or use of this material.
Safety Vision expressly disclaims all responsibility and
liability for the installation, use, performance, maintenance,
and support of third-party products. Customers are advised
to make their independent evaluation of such products.
No part of this document may be photocopied,
reproduced, or translated to another language
without the prior written consent of Safety Vision.
Safety Vision® is a registered trademark of Safety Vision,
LLC. All other products or name brands mentioned in this
document are trademarks of their respective owners. For
more information about Safety Vision and its products, go to
www.safetyvision.com or call 800-880-8855.

1TOTALVIEW HD USER GUIDE
CONTENTS
Product Features 2
Main Wiring Diagram 3
Remote Control 4
User Interface
Log In Interface 5
Password Reset 5
Main Menu Interface 6
System 7
Clock 8
AVM 8
AVM Option Setup 9
Import Calibration Files 9
Export Calibration Files 9
Change Vehicle Image 10
Information 10
Hardware Installation
Wiring of the Vehicle Body 11
Camera Installation 11
Control Box Installation 11
Calibration Mats 12
Software Calibration 13
Appendix A: Specications 16
Appendix B: Dimensions 17
FCC Compliance Statement 18

TOTALVIEW HD USER GUIDE 2
Product Features
• Four (4) 190° full HD 1080p wide-angle sheye
cameras, horizontal view angle >170° (8 channel inputs
maximum)
• Split screen to show 360° view and rear view OR 360°
view and front view as default.
• Dual-core ARM Cotex-A9 and built-in high
performance H.264 video encoding / decoding allow
for composite seamless, high accuracy images.
• Analog CVBS video output.
• Simple calibration procedures with automatic image
stitching.
• High denition 1080p HDMI video output.

3TOTALVIEW HD USER GUIDE
Main Wiring Diagram

TOTALVIEW HD USER GUIDE 4
Remote Control
1 - POWER - Turn on / o video display on or o.
2 - 0-9 - Input numbers.
3 - CLEAR - Delete a character.
4 - Navigation Keys - Use the left, right, up, and down keys
to navigate menus, move the cusor, or shift the image.
Press the center key to enter a command.
5 - ESC - Exit out of the main menu interface.
6 - SHIFT - Shift current channel to full screen display or exit
from full screen display. In the main menu interface it’s
used for switching the menu selection.
7 - MENU - Display the main menu.
Note: 2 AAA batteries are not included with remote control.
Important: Remote control is necessary to configure system if a
touchscreen monitor is not used.

5TOTALVIEW HD USER GUIDE
User Interface
Log In Interface
Input Password
Enter an alphanumeric password.
The default password should be
changed after stitching is nished.
The default password is 000000.
Note: If the password is forgotten, input
“root” to log in. Select factory default
setting in the Information menu. The
new password will be 000000.
Log In
After the password is entered, click
the Log In icon to log into the system.
Password Reset
Click the Password Reset icon to
change the current password.
Back
Click the Back icon to return to the previous menu.
Password Reset
The password reset screen provides access to
change the current password.
• Current: enter the current password
• New: enter the new password
• Confirm: conrm the new password by
entering it again.
• : save the current settings

TOTALVIEW HD USER GUIDE 6
Main Menu Interface
• System: basic function
setting
• Clock: system time setting
• Storage: storage function
and system log management
• DVR: Under development
• AVM: 360 panorama
calibration and related
operation
• Player: Under development
• Information: upgrade
operation and local IP setting
• Radar: Under development
Note: 0-9 numeric keys on remote control may be used to select
options in the menu (e.g. , press 5 to select AVM).

7TOTALVIEW HD USER GUIDE
System
• Standby Delay: time frame
can be set for standby
• AV: select color encoding
system
◦NTSC: 1080p / 60 frames
per second (fps)
◦PAL: 1080p / 50 fps
• Full Pannel AVS: Under
development
• Surround View Region:
select surround view size
◦Small
◦Normal
◦Large
• Language: Under development
• Slow Wakeup: Under development
• View Ratio: display ratio between birds eye view and
single view
◦1:2
◦2:3
◦1:1
• Front Cursor: front view cursor selection
• Surround View Mode: surround view mode selection
• UART Function: Under development

TOTALVIEW HD USER GUIDE 8
Clock
Click on the right / left arrows at the top of the
screen to scroll through month and year options.
Select the date by clicking today’s date on the
calendar. Click the up / down arrows at the bottom
of the screen to adjust the current time.
Once current time and date have been selected,
click the Save icon to save any changes. Then click
on the Back icon to return to the main menu.
AVM
The elds in the AVM Calibration
menu will be automatically populated
when calibration les are imported.
• Length: the total length of the
calibration mats from front to
back of vehicle centimeters
• Width: the total width of the
calibration mats from the left
side to right side of vehicle in
centimeters
• Chess Position: panoramic
stitching parameter
• Grid Size (in centimeters):
◦If using the 1.2m calibration
mats: 20
◦If using the 1.8m calibration mats: 30
• Blending Angle: panoramic stitching parameter
• : enter calibration mat setting menu
• : enter image stitching menu
• : enter AVM Option Setup

9TOTALVIEW HD USER GUIDE
AVM Option Setup
• : inport calibration les from USB
ash drive to system.
• : export saved calibration les
and single views to USB ash drive
• : change vehicle image
Note: Calibration files are saved as XML files.
Import Calibration Files
• File: Select calibration le with XML
extension
• :Conrm calibration le with
XML extension
Note: After the calibration file has been
imported, the system will restart.
Export Calibration Files
• :Conrm calibration le with
XML extension
Warning: Removing the USB flash drive
during export may corrupt the XML file.

TOTALVIEW HD USER GUIDE 10
Change Vehicle Image
This screen allows users to select
a vehicle image. Select one of the
available vehicle images across the top
or upload a custom vehicle image. Click
the Save button to apply changes.
Note: Custom vehicle images must be
saved as a .PNG file to be uploaded.
Note: After any changes are applied,
system will restart.
Information
• APP Version: Current APP
Flash version information /
upgrade les list / upgrade
conrmation key. This
function is activated only
when there’s APP upgrade
le HD360-CPU-APP-00-
Vx.x.xx.tar.gz under USB
ash drive root le.
• Firmware Version: Current
MCU Firmware version
information / upgrade les
list / upgrade conrmation
key. This function is activated
only when there’s MCU
upgrade le HD360-MCU-APP-00-Vx.x.xx.bin under
USB ash drive root le.
• IP Setup: IP address of control box
Note: There will be a indication red dot on upgrade key if
there’s new APP software or MCU firmware version under USB
flash drive root file.
Note: Do not pull out USB flash drive during system upgrade.

11 TOTALVIEW HD USER GUIDE
Hardware Installation
Wiring of the Vehicle Body
Wires should be run from the cameras to the control box.
Cameras must be positioned in the locations shown and
connected to its correct cable (e.g. camera in position
2 connected to the CAM2 cable on the control box).
Camera Installation
Note: Recommended minimum height is 1.5m.
1. Clean the area where the camera is to be installed.
2. Mark the positions of the two mounting screw
holes and cable exit hole.
3. Drill cable exit hole.
Using a hole saw or appropriate drill bit, drill a 7/8”
hole for the cable exit.
4. Drill mounting holes.
Using an appropriate drill bit, drill two mounting
screw holes where marked.
5. Position gasket on mounting surface.
Align the gasket holes with the two fastener anchors
on the mounting surface and place camera on the
gasket, threading the cable through the 7/8” hole.
Use the included mounting screws to secure the
camera into position.
6. Adjust camera view.
Using the included hex key, the front 4 screws may
be loosened in order to position the camera. Adjust
the camera angles and verify the normal image mark
(white dot on camera lens) is placed outward.
Control Box Installation
1. Using the included 4 mounting screws, mount the
control box in desired location.
2. Connect cabling to the control box.
3. Power on control box to test wiring connections.
4. Test operation functions.
Note: Camera 3 location is vehicle dependant, use the location that
allows the for the greatest coverage.

TOTALVIEW HD USER GUIDE 12
Calibration Mats
1. Use the provided adhesive tape to mark a rectangle
around the vehicle. Everything outside of the rectangle
will be part of the captured images.
2. Measure the length and width of the rectangle.
These measurements will be used later during software
calibration.
3. Place the calibration mats square, relative to each other
and the adhesive tape.
4. Conrm the aim and focus of each image. Each
view must contain all 4 corners of both mats and
contain the entire length of adhesive tape on that
side.

13 TOTALVIEW HD USER GUIDE
Software Calibration
The TotalView AHD system is congured
through proprietary software that
must be installed on a USB ash drive
and accessed with a Windows PC.
Use the following procedure to calibrate
the cameras through the software:
1. Enter the password and click the login icon.
The main menu appears.
The default password is 000000.
2. Once logged in, the Main Menu page is
displayed by default. Click on AVM.
The AVM Option Setup screen appears.
3. The AVM Option Setup
screen allows users to
select a vehicle image.
Select one of the available
vehicle images or upload a
custom image.
Custom vehicle images must
be saved as a .PNG file to be
uploaded.
4. After the vehicle image
is selected, click the Save
icon in the lower right
hand corner.
5. Click the Export icon on
the menu at the left side of the screen to
export the current conguration to a USB
ash drive.

TOTALVIEW HD USER GUIDE 14
6. In Windows, open the Calibration
Tool and click the File tab on
the top menu. Then select the
Directory exported to the USB ash
drive.
7. After the directory has been
imported, click on the Manual
Calibrate tab on the top menu.
Enter the length, width, and grid
size in centimeters.
• The length and width should
be the measurements that
were taken on step 2 under
Calibration Mats.
• Grid size will be:
◦120 for the 1.2m calibration
mats
◦180 for the 1.8m calibration
mats
8. For each of the 4 images, select the
corners of both calibration mats,
starting at the top left corner and
continuing clockwise.

15 TOTALVIEW HD USER GUIDE
9. Save the modied setup to the
USB ash drive.
10. Import the modied setup from
the USB ash drive into the control
box. If the import is successful the
system will automatically restart.
11. The nal result should look similar
to the picture on the right.

TOTALVIEW HD USER GUIDE 16
Appendix A: Specifications
IMAGE DEVICE
1/2.9” SONY CMOS (IMX323)
SCANNING SYSTEM
Progressive
SYNC. SYSTEM
Internal
FRAME RATE
PAL: 25 NTSC: 30
RESOLUTION
1080p
EFFECTIVE PIXELS
1920 (H) × 1080 (V)
IMAGE MODE
Normal
VIEWING ANGLE
200°
MINIMUM ILLUMINATION
0 Lux
NIGHT VISION DISTANCE
3~5m
VIDEO OUTPUT
1.0Vp-p, 75Ω
GAMMA CONSUMPTION
0.45
AUTOMATIC ADJUSTMENTS
AGC, BLC, white balance
SIGNALTONOISE RATIO
Better than 52dB
ELECTRONIC SHUTTER
1/30(1/25)~1/50,000 Seconds
POWER SUPPLY
12V DC
IP RATING
IP69K
AUDIO
No
STORAGE TEMPERATURE
-22° F ~ 176° F (–30° C ~ 80° C), RH 95% max.
OPERATING TEMPERATURE
-4° F ~ 158° F (–20° C ~ 70° C), RH 95% max.

17 TOTALVIEW HD USER GUIDE
Appendix B: Dimensions

TOTALVIEW HD USER GUIDE 18
FCC Compliance Statement
Note
This device has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference
when the equipment is operated in a commercial
environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may
cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Caution
Any changes or modications in construction of
this device which are not expressly approved by
the party responsible for the compliance could void
the user’s authority to operate the equipment.
Table of contents
Other Safety Vision Security System manuals
Popular Security System manuals by other brands

ITI
ITI 60-252 installation instructions

ALC
ALC AWS3377 user guide

Defender Security
Defender Security 812BF Operation guide

shelyak
shelyak Dome Tracker PF0004 user guide

Fire Burglary Instruments
Fire Burglary Instruments STAR XL4600DL Hookup and installation instructions

Tiras
Tiras DETECTO BTN100 quick start guide