manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Salto
  6. •
  7. Control Panel
  8. •
  9. Salto XS4 Reader User manual

Salto XS4 Reader User manual

This manual suits for next models

2

Popular Control Panel manuals by other brands

GENEVO PRiMA 6 installation manual

GENEVO

GENEVO PRiMA 6 installation manual

NAPCO X 255 - Programming instructions

NAPCO

NAPCO X 255 - Programming instructions

Next Systems UNIR1 230 instruction manual

Next Systems

Next Systems UNIR1 230 instruction manual

HORNER HE-XPW1E0 user manual

HORNER

HORNER HE-XPW1E0 user manual

DSC CLASSIC PC1555 instruction manual

DSC

DSC CLASSIC PC1555 instruction manual

Bosch Solution 2000 installation guide

Bosch

Bosch Solution 2000 installation guide

VRinsight MS Panel user manual

VRinsight

VRinsight MS Panel user manual

Zeiss SYCOP 3 Quick reference guide

Zeiss

Zeiss SYCOP 3 Quick reference guide

HULTSTEINS ECOFRIDGE DISPLAY user manual

HULTSTEINS

HULTSTEINS ECOFRIDGE DISPLAY user manual

Elkron C420 Programming manual

Elkron

Elkron C420 Programming manual

GST GST200-2 Installation and operation manual

GST

GST GST200-2 Installation and operation manual

Efka Variocontrol V810 instruction manual

Efka

Efka Variocontrol V810 instruction manual

RDZ PC-HRX user manual

RDZ

RDZ PC-HRX user manual

STG-BEIKIRCH MZ3 operation instruction

STG-BEIKIRCH

STG-BEIKIRCH MZ3 operation instruction

AMX AutoPatch CP-15 instruction manual

AMX

AMX AutoPatch CP-15 instruction manual

Cebora 208-10 instruction manual

Cebora

Cebora 208-10 instruction manual

Satel CA-6 KLED-S user manual

Satel

Satel CA-6 KLED-S user manual

Evolution IQ plus 800 installation manual

Evolution

Evolution IQ plus 800 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

All contents current at timeof publication.
SALTO Systems S.L. reserves the right to change availability of any
item in this catalog, its design, construction, and/or materials.
225648 -ED1 -04/06/2019
European view
©
2019 SALTO Systems S.L.
Installation guide
Panel reader
Installation
Installation Instalación Installation
Eng
DE
LIGHT AXIS
41
(1-5/8")
30
(1-3/16")
4
(3/16")
P1825
Installation guide
Installationsanleitung
Guía de instalación
Guide d'installation
D
Eng
E
F
3M SCOTCHLOK BUTT
CONNECTOR UY2 (X4)
TM TM
F
PANEL READER
FIXING STICKER
6
O
5
P1825
ON
Application Anwendung Aplicación Application
Eng
DEF
ALIGNED
LIGHT AXIS
METAL
METAL
1
2-a 2-b
3
4 5 6
COVER
STICKER
3M SCOTCHLOK BUTT
CONNECTOR UY2 (X4)
10
(25/64")
Length: 3m
1/4
50min.
60 min.
8max.
45
(1-3/4)
30
(1-3/15)
All contents current at timeof publication.
SALTO Systems S.L. reserves the right to change availability of any
item in this catalog, its design, construction, and/or materials.
225648 -ED1 -04/06/2019
European view
©
2019 SALTO Systems S.L.
Installation guide
Panel reader
Cable type Reader
UTP Cat5e 2 pairs
AWG24
UTP Cat5e 4 pairs
AWG24 +
SP224861/SP224895
Note
2
Twisted pairs
AWG18
279ft
85m
853ft
260m
1312ft
400m
Eng
Cable type and
max. distances
Cable type Reader
Electrical characteristics:
RF characteristics
Min Max Unit
Reader 150 mA
Min Cen. Unit
RFID frequency 13.56 Mhz
Bluetooth Smart
frequency 2.4 2.445 Ghz
Note 1: Installer must take this data into account
to dimension the CU42xx power supply.
Panel Reader only for use with the SALTO Control
Units.
Note 2: Not use with Scotchlock butt connector
UY2.
SALTO recommends to use one cable per wall
reader.
Power Consumption Note1
Cable type Reader
UTP Cat5e 2 pairs
AWG24
UTP Cat5e 4 pairs
AWG24 +
SP224861/SP224895
Note
2
Twisted pairs
AWG18
279ft
85m
853ft
260m
1312ft
400m
D
Verkabelung und max.
entfernungen
Kabeltyp Leser
Elektronische Eigenschaften:
RF Frequenzen
Min Max Einheit
Reader 150 mA
Min Cen. Unit
RFID frequenz 13.56 Mhz
Bluetooth Smart
frequenz 2.4 2.445 Ghz
Note1: Bitte beachten Sie die Stromaufnahme bei
der Planung des Netzteils für die CU42xx.
Note2: Nicht verwenden mit den Scotchlok
Einzeladerverbinder UY2.
SALTO empfiehlt die Verwendung einer separaten
Leitung je Wandleser.
Stromaufnahme Note1
Cable type Reader
UTP Cat5e 2 pairs
AWG24
UTP Cat5e 4 pairs
AWG24 +
SP224861/SP224895
Note
2
Twisted pairs
AWG18
279ft
85m
853ft
260m
1312ft
400m
E
Tipo de cable y
distancias max.
Cable type Lector
Características eléctricas:
RF characteristics
Min Max Unidad
Lector 150 mA
Min Cen. Unit
Frecuencia RFID 13.56 Mhz
Frecuencia
Bluetooth Smart
2.4 2.445 Ghz
Nota1:El instalador ha de tener en cuenta la
dimensión del alimentador de la CU42xx.
Nota2:No usar el conector Scotchlook butt UY2
con este tipo de cable.
SALTO recomienda utilizar un cable por cada lector
mural.
Consumo Nota1
Cable type Reader
UTP Cat5e 2 pairs
AWG24
UTP Cat5e 4 pairs
AWG24 +
SP224861/SP224895
Note
2
Twisted pairs
AWG18
279ft
85m
853ft
260m
1312ft
400m
F
Type de câble
Type de câble Lecteur
Caractéristique électronique:
RF characteristics
Min Max Unité
Reader 150 mA
Min Cen. Unit
Fréquence RFID 13.56 Mhz
2.4 2.445 Ghz
Note1:L'installateur doit calculer l'alimentation
nécessaire pour alimentere la CU42xx.
Note2: Ne pas utiliser le connecteur Scotchlok UY2
avec ce type de câble.
SALTO recommande d'utiliser un câble pour
chaque lecteur mural.
Consommation Note1
Einheit
Unidad
Fréquence
Bluetooth Smart
2/4
Min. Max. Unit
Temperature WRDP0B -30 70 ⁰C
Temperature WRDP0J -25 70 ⁰C
Humidity 35 85 %
Operation conditions
Max.
2.4835
Max.
2.4835
Max.
2.4835
Max.
2.4835
Min. Max. Einheit
Temperatur WRDP0B -30 70 ⁰C
Temperatur WRDP0J -25 70 ⁰C
Feuchtigkeit 35 85 %
Umgebungsbedingungen
Min. Max. Unidad
Temperatura WRDP0B -30 70 ⁰C
Temperatura WRDP0J -25 70 ⁰C
Humedad 35 85 %
Condiciones ambientales
Min. Max. Unit
Température WRDP0B -30 70 ⁰C
Température WRDP0J -25 70 ⁰C
Humidité 35 85 %
Condition de fonctionnement
213ft
65m
656ft
200m
984ft
300m
Note:
UL tested at 100m
at 24 AWG.
All contents current at timeof publication.
SALTO Systems S.L. reserves the right to change availability of any
item in this catalog, its design, construction, and/or materials.
225648 -ED1 -04/06/2019
European view
©
2019 SALTO Systems S.L.
Installation guide
Panel reader
READER 1
A
B
TAMPER
IN1
IN2
IN3
IN4
IN5
IN6
READER 2
RL1
RL2
RL3
RL4
C
NC
NO
C
NC
NO
C
NC
NO
C
NC
NO
BUS485
Ethernet
10Base-T
100Base-TX
ON
12V
DC
Input
+
A
B
-
12V
DC
Output (1A)
Power Input: 12VDC-1A
GND
GND
+
-
+
-
+
-
+
-
+
-
+
-
+
-
A
B
+
-
Model:
CU42E0
D
Eng
E
F
D
Eng
E
F
Verde
Amarillo
Negro
Rojo
Vert
Jaune
Noir
Rouge
Grün
Gelb
Schwarz
Rot
B
A
Green
Yellow
Black
Red
+V
Eng D E F
Installation example Installationsbeispiel Ejemplo de instalación Exemple d'installation
Only connect ti CU42xx
Nur für Steuereinheit CU42xx
Solo conectar a CU42xx
Connecter uniquement CU42xx Same pair
Gleiches Paar
Mismo par
Même paire
3M Scotchlok butt connector UY2. Crimp with cap side down.
3M Scotchlok butt Einzeladerverbinder UY2. Mit der Kappe nach unten
zusammendrücken.
Conector 3M Scotchlok butt UY2. Crimpar con la tapa hacia abajo.
Connecteur 3M Scotchlok butt UY2. Crêper avec le capuchon vers le bas.
D
Eng
E
F
TM TM
TM
TM
TM
TM
TM
TM
Only connect to CU42xx
Nur für Steuereinheit CU42xx
Solo conectar a CU42xx
Connecter uniquement CU42xx
D
Eng
E
F
Minimum distance between readers 20in (50cm).
Mindestabstand zwischen Lesern 20in (50cm).
Distancia mínima entre los lectores 20in (50cm).
Distance minimale entre les lecteurs doit être de 20in (50cm).
D
Eng
E
F
D
Eng
E
F
READER 1
A
B
12V
DC
Input
TAMPER
IN1
IN2
IN3
IN4
IN5
IN6
READER 2
RL1
RL2
RL3
RL4
+
A
B
-
C
NC
NO
C
NC
NO
C
NC
NO
C
NC
NO
BUS485
Model:
CU4200
12V
DC
Output (1A)
ON
Power Input: 12V
DC
-1A
GND
GND
+
-
+
-
+
-
+
-
+
-
+
-
+
-
A
B
+
-
SP224861 SP224895
Eng
Installation example with RJ45 Installationsbeispiel für RJ45 Ejemplo de instalación RJ45 Exemple d'installation avec RJ45
D
Eng
E
F
D
Eng
E
F
Optional
Optioneel
Opcional
Optionnelle
D
Eng
E
F
Optional
Optioneel
Opcional
Optionnelle
Black
Schwarz
Negro
Noir
Red
Rot
Rojo
Rouge
DE
3/4
Use of RJ45
connectors not
evaluated by UL
Eng F
DE
Eng F
All contents current at timeof publication.
SALTO Systems S.L. reserves the right to change availability of any
item in this catalog, its design, construction, and/or materials.
225648 -ED1 -04/06/2019
European view
©
2019 SALTO Systems S.L.
Installation guide
Panel reader
4/4
UL Statements
-
UL294 performance level:
FEATURE LEVEL
Destructive attack I
Line Security I
Endurance IV
Standby power I
-
Comply with ULC-S319 Class I *.
Tested by UL with Mifare (DESFIRE, ULTRALIGHT C) and HID iCLASS RFID communication, and with Mobile APP (JustIN Movile version 2.x) through
Bluetooth version 4.2. Minimum Operating Systemversion for Android: 4.3 or later and for iOS: 10.0 or later. A means of verification shall be
employed by the user to enable access to the wireless electronic device such as a PIN or biometric feature. The wireless electronic device is
not capable of command, control, programming, or any other system manipulation and it is only to be used in the same manner as a physical
credential
Wiring methods that shall be in accordance with the National Electrical Code, ANSI/NFPA 70
or CSA C22.1-02 - Canadian Electrical Code,
Part 1, Safety Standard for Electrical Installations
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation. Changes or modifications not expressly appproved by the party responsible for compliance could void the user's
authority to operate the equipment.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
This device has been tested and found to comply with the limits for a Class B digital device, pursant to ICES-003.
* Note: shielded wire shall be used.
** Note: WRDx
P
xx
Y
model, not UL listed.