Salus MD28S User manual

Instruction Manual
28mm in-line Magnetic Filter
Model: MD28S
www.salus-controls.com
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS Controls plc reserve the right
to change specification, design and materials of products listed in this brochure without prior
notice.
Head Office:
SALUS Controls
Units 8-10, Northfield Business
Park, Forge Way, Parkgate
Rotherham, S60 1SD
Email: [email protected]
www.salus-controls.com
Issued: Mar 2023
V02
The following instructions are designed to help the engineer to install
and maintain the Magnetic Filter safely and eciently and should be
followed and adhered to at all times. Make sure there is a water-lling
pipeline behind the lter. During maintenance, check whether the lid
seals are worn or damaged. The best practice is to replace the lid seal at
each repair.
The Magnetic Filter is specially designed for central heating systems. It can
remove almost all the harmful black suspended iron oxide particles accumulated
in the central heating system and protect the complete central heating system.
The lter can be installed in a variety of ways, for example: be installed at any
location on the main pipeline. However, it is recommended to be installed
after the last radiator and before the boiler on the primary return pipework for
maximum protection and eciency.
Note: It is important to have adequate access for maintenance and
servicing when determining a suitable installation location.
1 Air vent valve
2 Magnet bar
3 Drain valve
4 Inlet valve
5 Outlet valve
Open vented system
Figure 2
Combination/Sealed system
Figure 1
1. INTRODUCTION
3. STRUCTURE INTRODUCTION
2. MOUNTING RECOMMENDATIONS
Recommended installation location
RETURN
Boiler
RETURN
Boiler
Pump
Header Tank
Vent
Pipe
2
1
3
4
5
Heat pump
Heat pump
4. INSTALLATION METHOD
5. MAINTENANCE AND SERVICING
Instruction manual of magnetic lter
1. Cut and remove the section of the pipe according to the product installation length;
2. Install the valves onto the pipework, hand tighten only at rst, then tighten securely the valve to the pipe;
3. Install the lter housing and tighten it;
4. Adjust the Angle and secure the lter;
5. Make sure the valves are open, allow the system to ll, open, and vent the lter through the air vent valve,
close when complete.
1. Close both the isolation valves;
2. Open the drain valve, place a bucket or similar receptacle below ready to collect the debris. Take out the
magnetic bar and store in a safe place;
3. Open the inlet valve to ush out the debris, once all the debris has been removed introduce a suitable
chemical inhibitor into the system, we recommend Salus LX1 inhibitor, ret the magnetic bar;
4. Open the inlet and outlet valve, vent the lter through the air vent valve close when complete.
Check for any leaks;
5. Complete any relevant documentation.
IE: Dates and inhibitor used.
1. The magnetic lter contains powerful magnets, please keep away from all electronic devices, bank cards
and other magnetic devices;
2. The Magnetic Filter contains powerful magnets and should always be used with caution especially for
devices such as pacemakers;
3. The Magnetic Filter is a pressurized device, pressure must be released prior to maintenance;
4. The Magnetic Filter device could be very hot during operation. Please be careful!
* In order to maintain grounding continuity in accordance with the current IEE regulations, appropriate grounding cables should be
installed on the pipe where necessary to bypass the product.
* Please read the product manual carefully before installation and use.
123 4
12 3 4
Note: Prior to carrying out any maintenance work, isolate the electrical supply to the boiler allowing
the water to cool down to a safe working temperature.
Note: It is recommended that the magnetic lter is installed and maintained by a competant and
qualied person. Any queries arising from either installation or servicing, contact SALUS Controls at
[email protected]
Maximum working pressure: 6bar Maximum operating temperature: 95 °C
Flow rate: < 50 l/min Direction of ow: follow the arrow
Please note:

Other Salus Water Filtration System manuals

Salus MD22S User manual

Salus

Salus MD22S User manual

Salus MD22A Installation manual

Salus

Salus MD22A Installation manual

Salus MAG Defender MD22 Owner's manual

Salus

Salus MAG Defender MD22 Owner's manual

Salus MAG Defender MD22 User manual

Salus

Salus MAG Defender MD22 User manual

Popular Water Filtration System manuals by other brands

Plumbline PD1000C owner's manual

Plumbline

Plumbline PD1000C owner's manual

Aqua ADLASN operating instructions

Aqua

Aqua ADLASN operating instructions

DiaSys O-Classic Operator's manual

DiaSys

DiaSys O-Classic Operator's manual

Blanca Atmospheric Water Maker user manual

Blanca

Blanca Atmospheric Water Maker user manual

EHEIM 2010 manual

EHEIM

EHEIM 2010 manual

GE Zoneline RAK13 installation instructions

GE

GE Zoneline RAK13 installation instructions

Coway P-6320R user manual

Coway

Coway P-6320R user manual

US Water Systems Fusion Service manual

US Water Systems

US Water Systems Fusion Service manual

entegris Chemlock Installation and use manual

entegris

entegris Chemlock Installation and use manual

Hydac OF5 CM Operating and maintenance instructions

Hydac

Hydac OF5 CM Operating and maintenance instructions

intatec IntaKlean Nano IKN34 Installation & servicing instructions

intatec

intatec IntaKlean Nano IKN34 Installation & servicing instructions

ERICO DSF-6A-30V installation instructions

ERICO

ERICO DSF-6A-30V installation instructions

Grunbeck GENO-OSMO RO 125K Operation manual

Grunbeck

Grunbeck GENO-OSMO RO 125K Operation manual

Omnifilter LN3 Series A installation instructions

Omnifilter

Omnifilter LN3 Series A installation instructions

Aquatek ATPRO-50 Installation instructions manual

Aquatek

Aquatek ATPRO-50 Installation instructions manual

brondell UC 300 installation guide

brondell

brondell UC 300 installation guide

Intex CS2110 owner's manual

Intex

Intex CS2110 owner's manual

EOS Hitech JAY 101 user manual

EOS Hitech

EOS Hitech JAY 101 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.