Table of Figures
Table of Figures
[Figure 2-1: Electrical connections] ..............................................................................................................5
[Figure 2-2: Name Plate] ..................................................................................................................................7
[Figure 2-3: PV connections]...........................................................................................................................8
[Figure 2-4: Distribution box connection diagram].................................................................................8
[Figure 2-5: Derating Curve]........................................................................................................................ 11
[Figure 2-6: Power efficiency curve of System]...................................................................................... 11
[Figure 2-7: Power efficiency curve of PV Generation]........................................................................ 12
[Figure 3-1: Part View of Samsung All in One] ....................................................................................... 15
[Figure 4-1: Front status indication screen]............................................................................................ 16
[Figure 4-2: PV generation, battery charge, Load use, sell remaining amount].......................... 17
[Figure 4-3: PV generation, battery discharge, Load use, buy shortage amount] ...................... 17
[Figure 4-4: PV generation, Battery standby, Load use, sell remaining amount]........................ 17
[Figure 4-5: PV generation, Sell remaining amount]............................................................................ 17
[Figure 4-6: PV generation, Buy shortage amount].............................................................................. 18
[Figure 4-7: Battery discharge, Load use] ................................................................................................ 18
[Figure 4-8: Battery discharge, Load use, Buy shortage amount].................................................... 18
[Figure 4-9: Indication screen on Standby Mode]................................................................................. 19
[Figure 4-10: Indication screen on Forced charged Mode]................................................................ 19
[Figure 4-11: Indication screen on stand-alone mode]....................................................................... 19
[Figure 4-12: Event occurrence, Grid RMS over current protection]............................................... 20
[Figure 4-13: Event occurrence, DC link over voltage protection]................................................... 20
[Figure 4-14: Event occurrence, PV string1 reverse connection protection]................................ 20
[Figure 4-15: Event occurrence, PV string2 reverse connection protection]................................ 20
[Figure 4-16: Event occurrence, PV string1 over voltage protection]............................................. 21
[Figure 4-17: Event occurrence, PV string1 over current protection] ............................................. 21
[Figure 4-18: Event occurrence, PV string2 over voltage protection]............................................. 21
[Figure 4-19: Event occurrence, PV string2 over current protection]............................................. 21
[Figure 4-20: Event occurrence, Battery over voltage protection] .................................................. 21
[Figure 4-21: Event occurrence, Battery over current protection]................................................... 22
[Figure 4-22: Event occurrence, On sequence Inverter DC link event]........................................... 22
[Figure 4-23: Event occurrence, On sequence Battery V/I event] .................................................... 22
[Figure 4-24: Event occurrence, Normal Inverter DC link event]...................................................... 22
[Figure 4-25: Event occurrence, Normal Battery V/I & BDC DC link event].................................... 22
[Figure 4-26: Event occurrence, On sequence Inverter DC link event]........................................... 23
[Figure 4-27: Event occurrence, Normal Inverter DC link & PV I event].......................................... 23
[Figure 4-28: Event occurrence, Temperature protection] ................................................................ 23
[Figure 4-29: Event occurrence, Over Current TZ Fault]...................................................................... 23
[Figure 4-30: Events occurrence, temperature sensor connection error] ..................................... 23
[Figure 4-31: Event occurrence, PV mis-wiring]..................................................................................... 24
[Figure 4-32: Event occurrence, SPI communication event] ............................................................. 24
[Figure 4-33: Event occurrence, Single fault event] ............................................................................. 24
[Figure 4-34: Event occurrence, Continuously 3 times Inverter fault]............................................ 24
[Figure 4-35: Indication screen on Application Download Mode] .................................................. 24
[Figure 4-36: Initial indication screen on power on] ............................................................................ 25
[Figure 4-37: Standby state indication screen before the EMS command] .................................. 25
[Figure 5-1: Communication terminal]..................................................................................................... 26
[Figure 5-2: Connecting to the website].................................................................................................. 28
iv Australia (Eng.) 05/2015. Rev1.1