Ubigate iBG2016 Configuration Guide/Ed.00 
© SAMSUNG Electronics Co., Ltd. VII 
 
3.
 Warning to service personnel: ‘CAUTION: Double pole/neutral fusing’ 
 
4.
 Telephone line cord: ‘CAUTION: To reduce the risk of fire, use only No. 
26 AWG or larger(e.g., 24 AWG) UL Listed or CSA Certified 
Telecommunication Line Cord’ 
 
5.
 Leakage currents due to ringing voltage - Earthing installation 
instructions: ‘1.A supplementary equipment earthing conductor is to be 
installed between the product or system and earth, that is, in addition to 
the equipment earthing conductor in the power supply cord. 2.The 
supplementary equipment earthing conductor may not be smaller in size 
than the unearthed branch-circuit supply conductors. The equipment 
earthing conductor is to be connected to the product at the terminal 
provided, and connected to earth in a manner that ill retain the earth 
connection when the power supply cord is unplugged. The connection to 
earth of the supplementary earthing conductor shall be in compliance 
with the appropriate rules for terminating bonding jumpers in Part K of 
Article 250 of the National Electrical Code, ANSI/NFPA 70 and Article 
10 of Part 1 of the Canadian Electrical Code, Part 1, C22.1. Termination 
of the supplementary earthing conductor is permitted to be made to 
building steel, to a metal electrical raceway system, or to any earthed 
item that is permanently and reliably connected to the electrical service 
equipment earthed. 3.Bare, covered, or insulated earthing conductors are 
acceptable. 
A covered or insulated conductor must have a continuous outer finish 
that is either green, or green with one or more yellow stripes.’ 
 
6.
 Safety Instructions - Rack Mount ‘Rack Mount Instructions - 
 The following or similar rack-mount instructions are included with the 
 installation instructions: 
 
A) Elevated Operating Ambient - If installed in a closed or multi-unitrack 
assembly, the operating ambient temperature of the rack environment 
may be greater than room ambient. Therefore, consideration should be 
given to installing the equipment in an environment compatible with the 
maximum ambient temperature(Tma) specified by the manufacturer. 
 
B) Reduced Air Flow - Installation of the equipment in a rack should be 
such that the amount of air flow required for safe operation of the 
equipment is not compromised.