■ FEATURES AND SPECIFICATIONS
1. Max capacity: 10kg
2. With high precision strain gauge sensor
3. Calendar/Time/Alarm timer/Temperature/Humidity function
4. Hang on the wall or on the desk
5. Indicate volume of water and milk
6. Two unit systems: g(kg), lb:oz convertible
7. With Zero / Tare function
8. Low battery power/Overload indication
__________________________________________________________________
■ LCD DISPLAY
Effective weighing area
LCD display area
Battery case
cover
Kickstand
AM/PM
Calendar
Alarm timer
Week
Mode
Tare
Zero
Negative Value
Volume unit
Weight unit
Humidity unit
Humidity
percentage
Weight unit
Weighing mode
Water volume mode
Milk volume mode

■ KEY ILLUSTRATION
__________________________________________________________________________________
■ TO INSTALL OR REPLACE BATTERY
2 x 1.5V ( AA/AAA) batteries (excluded).
Remove package foil before use;
A. Take out used batteries, with the aid of a
sharp object if needed.
B. Install new batteries by putting one side of
the battery down first and pressing down
the other side.
(Please observe the polarity)
__________________________________________________________________________________
■ CALENDAR AND TIME SETTING
1. Install battery to switch on and enter year setting automatically. Press ▲▼to adjust and
for confirmation in turn.
2. Under time setting mode, press for 3 seconds to enter setting: Set
Year/Date/Time in turn. Press ▲▼ to adjust and SET for confirmation. (Continuous
pressing ▲▼ will speed up the advance of value or the decrease of value.)
3. Press to confirm time and Second starts from “0”.
4. In setting process, return to real time display automatically after idling for 60 seconds.
Remark: The time mode (12/24 hour) depends on sales destination or the requirement
of distributor.
________________________________________________________________________________
■ TO START WEIGHING
1. Weighing mode
A. Place the scale on a solid and flat surface.
B. Under real time display mode, press to convert to weighing mode and
wait until LCD shows “0”.
C. If LCD shows weighing mode, please enter to Step D directly.
If LCD shows volume mode, please press to convert to weighing
mode, and then enter Step D.
D. Load weighing object on scale (or bowl) to start weighing, LCD will show the
weighing reading.
E. Place bowl (if used) on the scale and tare the reading before weighing. (Tare
function described additionally)
2. Volume indication mode
Setting
Unit conversion / Down Zero/Tare/Up Convert
Press to
E
nter month setting
Install battery to switch on, Default
year: 2012, Press to adjust
Press to adjust
Press to
enter date setting
Press to adjust
Press to
enter minute setting
Press to adjust
Press to adjust
Press to
Enter hour setting
Press
to confirm
Milk volume mode
Weighing mode
Load weighing
mode
Show weighing reading
Real time display

A. Place the scale on a solid and flat surface
B. Under real time display mode, press
to convert to weighing mode and wait until
LCD shows “0”.
C. Press to convert to Water or Milk
mode (Refers to mode setting specifically)
D. Put a liquid container onto the scale platform,
LCD shows the weight of container
E. Press to reset “0” and tare.
F. Pour liquid (water or milk into the container,
LCD shows the volume of the liquid.
G. Press to convert to weighing mode,
and check the weight of liquid.
■ UNIT AND MODE SETTING
If the scale is with both measuring systems of Metric (g,kg) and Imperial (oz, lb), you
can press ”unit” convert between two systems during the course of weighing:
1. Press shortly to convert weight unit between Metric and Imperial
systems.
2. Under weighing mode, press shortly to convert between weighing
mode and volume mode (water or milk).
Metric system:
Remark: The unit system of scale depends on sales destination or the requirement
of distributor.
■ “ZERO” OR “TARE” FUNCTION
Continuous press
Press
shortly
Press
shortly
Press
Shortly
Press
shortly
Press
Shortly
Press
shortly
Imperial system:

To weigh different loads consecutively without removing loads from the scale. Put
first load on the scale get weight reading. Press button to reset the LCD
reading to “0” before adding next load. You can repeat this operation.
Condition 1: “ZERO” function
When total sum of all loads on scale ≤ 4%
LCD will show “-----“ or “0g” each time is
pressed. “-----“ means not stable, please wait for a
moment. “0g” and meanwhile an icon “ ” on upper left
corner of LCD mean “ZERO” function is active. Max.
weight capacity remains unchanged.
Condition 2: “TARE” function
When total sum of all loads on scale > 4%
LCD will show “-----“ or “0g” each time is
pressed. “-----“ means not stable, please wait for a
moment. “0g” and meanwhile an icon “ ” on upper left
corner of LCD mean “TARE” function is active. Max.
Weight capacity reduced by total weight of all loads.
___________________________________________________________________
■ TO CONVERT BETWEEN WEIGHING MODE AND REAL
TIME DISPLAY MODE
■ TO SET ALARM TIMER
1. When setting time span, touch to confirm and prompt to next digit. After
setting time span, touch to start counting down. During counting down,
touch to clear the set time span.
2. The time counts down to “00:00”, alarm will start “beeping” for 60 times and the
scale will automatically return to real time display mode.
3. Touch any key to stop “beeping”.
4. Max time span of the alarm timer: 99:55.
___________________________________________________________________________
■ TO SET ALARM TIMER
Temperature range: 0~50 ºC, Division: 1 ºC
Humidity range: 30~95%, Division: 5%
■ WARNING INDICATORS
Idle for 120 seconds
Press
to return
quickly
Real time display
Press
Press to adjust
Start alarm timer
Press
Press
Press to adjust
Press
Press to adjust
Press
Press to adjust

1. Replace new battery.
2. Scale overload. Remove item to avoid
damage. Max. weight capacity is
indicated on the scale.
_________________________________________________________________
■ HAND ON THE WALL OR ON THE DESK
1. Scale can be put on the desk as a clock or decoration if lay the kickstand on the
back of scale.
2. Scale can be hanged up on the wall by the hole. (Hook on wall not included)
* Picture for reference only, please prevail in actual item.
_________________________________________________________________
CLEANING AND CARE
1. Clean the scale with a slightly damp cloth. DO NOT immerse the scale in water or use
chemical/abrasive cleaning agents.
2. All plastic parts should be cleaned immediately after contact with fats, spices, vinegar
and strongly flavoured/coloured foods. Avoid contact with acids citrus juices.
3. Always use the scale on a hard, flat surface. DO NOT use on carpet.
4. DO NOT strike, shake or drop the scale.
5. The scale is high precision device. Please take care of it.
6. Please keep it dry.
7. Please check whether battery is installed or in high level if scale cannot be turned on.
8. The scale is for family use only, not for commercial purpose.
Hole
Kickstand
Hole
This hole can be pull
out in use and back
after use.