SANKI P212 User manual

PIEZO FEEDER CONTROLLER
Instruction Manual
【Single-Function Type】
P212
P312
This Instruction Manual is applicable to Piezo
Feeder Controller version 2 and later.
Confirm the version information displayed
upon powering ON.
Ver. 2
Read the Manual carefully beforehand to ensure the safe use of the Controller.
After reading, store the Manual within reach so as to be ready for rereading.
The dealer is requested to be sure to deliver the Manual to the end user.


1/20
Contents
1.Introduction 2
2.Before Using 2
3.Precautions for Safety 2
4.Name of Each Part 4
5.First-Time Use 6
6.Input/Output Connections 7
7.Operation Panel 9
7-1.Explanation of Operation Panel
7-2.Displayed Mode
7-3.Setting the Frequency Lock
7-4.Preparation for Operation
8.Operation and Amplitude Adjustment Method 11
9.Added Function 13
10.Initialization of the Set Data 13
11.Remote Unit (RCU-3A) 14
12.Parameter Setting Method 15
13.Guard and Alert 16
14.Troubleshooting 17
15.Options 17
16.Specifications 18
17.Outside Dimensional Drawing 19
18.Warranty 20

2/20
1. Introduction
Thank you for your selection of our Piezo Feeder Controller, a digital controller for piezo feeder
(“Controller”).
The piezo feeder is a high-efficiency, energy-saving parts feeder driven by piezoelectric elements.
In combination with the dedicated digital controller, the Controller can be operated easily and
efficiently without requiring any difficult adjustment. Before connecting the piezo feeder and
performing subsequent adjustment, read the Manual carefully to ensure proper use of the excellent
functions of the piezoelectric parts feeder.
2. Before Using
Before unpacking, be careful not to have an impact or vibration on the packing.
Unpack, and check the following:
(1) Isn’t there any damage caused during transport?
(2) Are the rating, capacity and model on the nameplate exactly what you have ordered?
If there is any problem, contact the dealer.
3. Precautions for Safety
Be sure to read the Manual carefully before the installation, operation, maintenance, checkup, etc.
of the Controller to ensure your familiarity with the Controller, safety information and precautions.
In the Manual, the safety precautions are divided into “DANGER” and “CAUTION” according to
their severities.
DANGER
If the Controller is handled improperly, a dangerous situation could be
caused, and the possibility of death or injury is assumed.
CAUTION
If the Controller is handled improperly, a dangerous situation could be
caused, and the possibility of medium or minor injury or partial damage is
assumed.

3/20
DANGER
・Do not service the Controller in the Power-ON status. To avoid an electric shock, be sure to turn
OFF the power supply before starting the service.
・Do not disassemble, remodel or repair the Controller, or an electric shock, a fire or injury could be
caused. For repair, ask the dealer.
・Do not remove the front cover while the Controller is in the Power-ON status, or an electric
shock could be caused.
・Do not put or insert anything in or into the Controller, or an electric shock or a fire could be
caused.
・Do not use the Controller near explosive or flammable gas, or a fire could be caused.
・Do not splash water or liquid, or an electric shock or a fire could be caused.
・If smoke, odor or abnormal noise is emitted or other abnormality is detected, shut down the
Controller immediately. If the Controller is used in the abnormal status, a fire could be caused.
Contact the dealer.
・If the Controller is not operated for a long time, shut down the Controller. If the Controller is left
live as it is, a fire could be caused.
・Connect the power cable and the output cable as instructed in the Manual to avoid an electric
shock and a fire.
・Do not forcedly bend, pull or pinch the power cable or the output cable, or an electric shock or a
fire could be caused.
・Ground the earth terminal and the ground prescribed portions without fail, or an electric shock
could be caused. When working on grounding to a high position or a shaky stand, because fall or
tumble could be caused conditionally, take measures to prevent fall or tumble.
・Do not conduct megger testing for any terminals other than the input terminal.
CAUTION
・Do not use the Controller for an electromagnetic parts feeder or the like.
・Do not turn ON/OFF the power supply frequently, or failure could be caused.
・Do not start/stop the vibrator with an electromagnetic contactor or the like on the output side,
or failure could be caused.
・Do not perform welding work on the feeder side in the Power-ON status.
・Do not perform welding work on the feeder side when the feeder and the Controller are in the
connected status.
・Do not remove the nameplate, the seal, or the like.
・When installing the Controller, hold and fix it firmly and properly.
・Do not transport or carry the Controller in the piled-up status, even in the packed status, or they
could fall, causing injury.
・Do not place the Controller outdoors, in a humid place or in a place with excessive temperature
change.
・Do not pile up the Controller two-tired or more, even in the packed status.
・When disposing of the Controller, dispose it properly as general industrial waste.

4/20
4. Name of Each Part
Operation panel removed status
Power cable (1m)
Output cable (1m)
Operation panel
Rubber bush
Relay connector
Operation panel fixing
screw (2 locations)
Earth
Operation panel
connecting wire
Operation panel
When attaching/detaching
the operation panel, carefully
watch out for disconnection,
pinching, etc.
External control
terminal block

5/20
Terminal block No.
Wiring to the external signal terminal block (screw-less)
While holding down the button on the terminal block with a
flat-blade screwdriver or similar, insert the wire into the
wire insertion hole. Then, detach the flat-blade screwdriver
to release the button, and the wire will be fixed.
Applicable wire size
Stranded wire: 0.08 –0.32mm2 (AWG28 –22), Strand diameter: φ0.12mm or more
Solid wire: φ0.32 – 0.65mm (AWG28 –22)
Wire strip length: 9 –10mm
Wire insertion
hole
Button
P-
S-
S+
P+

6/20
5. First-Time Use
Starting operation flow
Input/output connection
・Connect the input and the output cables.
・Connect the external I/O signals.
Amplitude adjustment
Adjust the amplitude to optimize the work transfer speed.
Outputs the setting (output voltage, frequency) for a certain
length of time.
・Set the output voltage and the frequency manually.
Added function
・Set the soft start and the soft stop.
Normal operation

7/20
6. Input/Output Connections
1) Vibratory feeder drive connection
Confirm that the power supply is in the OFF status. Then, connect the output cable of the
controller to the feeder cable of the piezo feeder.
The connector wire colors should be identified as follows:
※1: Do not connect any feeder other than the piezo feeder made by Sanki.
※2: Do not operate with no load.
※3: Be sure to ground the feeder.
2) Power source connection
Connect the power cable to the single-phase power source.
Do not turn ON the power supply until the whole wiring work is completed.
※1: Be sure to connect to the utility power source.
※2: Be sure to ground the controller.
※3: Do not perform the ON/OFF control on the input power supply side.
100-230VAC
Piezo feeder
Black
White
ピエゾフィーダ
Feeder cable

8/20
3) External signal [in1 Input] connection
The operation/stop of the feeder is operated according to external signal.
When the external signal is not used, set parameter as “Parameter No. 06 = Lo.”
※1. To connect the external signal, the operation panel should be removed.
Confirm that the power supply is in the OFF status. Then, detach the operation panel.
After the connection is completed, attach the operation panel, and then turn ON the power
supply.
The operation panel is connected to the main unit of the controller with a connecting wire.
When attaching/detaching the operation panel, carefully watch out for disconnection or
pinching.
※2. The [+P] –[-P] line can also be used as an outlet of 24VDC, 160mA.
To operate the start/stop of the controller according to external control signal, either method
of non-voltage contact signal or voltage signal (24VDC) can be used.
Make connection to the external control terminal block by using the method ①or ②below
while watching out for the signal to be used and the connection method. When wiring, be careful
not to make mistake about the polarity.
The current of 24VDC and 10mA or less flows between [+S] and [-S]. Carefully select the
connection device (e.g., minute current relay).
①No-voltage contact signal ②Voltage signal (24VDC)
[in1 Input logic]
Signal input status
Feeder operation condition
Setting: hi
Setting: Lo
in1 Input
Parameter No. 6
Connection ①:
Close
Connection ②:
24VDC
Operation condition
Stop
Connection ①:
Open
Connection ②:
0V
Stop
Operation condition
□: Default
Short circuit
No-voltage
contact
Example of circuit to be
arranged by customer
Internal circuit
Internal circuit
Example of circuit to be
arranged by customer

9/20
7. Explanation of Operation Panel
7-1. Explanation of Operation Panel
1) Pilot lamps
2) Operation keys
No
Name
Function
A
ON/OFF key
Performs the forced operation and the forced stopping.
B
Func key
Brief pressing: Switches the frequency lock setting.
Long pressing: Switches the mode between the parameter mode and the
normal mode.
C
Set key
Brief pressing: Changes and locks the data.
D
Vol ▲key
Normal mode: Adjusts the output voltage.
When pressed briefly when the frequency is being displayed,
the frequency display switches to the voltage display.
Parameter mode: Selects the parameter No.
E
Vol ▼key
F
Freq ▲key
Normal mode: Adjusts the frequency.
When pressed briefly when the voltage is being displayed,
the voltage display switches to the frequency display.
Frequency lock setting display: Changes the frequency lock setting.
Parameter mode: Changes the parameter data.
G
Freq ▼key
No
Name
Function
①
Data display
A 7-segment, 4-digit LED
Displays voltage, frequency,
each settings and error
codes.
②
Frequency pilot
lamp
ON when the data display
is showing frequency
③
Voltage % pilot
lamp
ON when the data display
is showing voltage
④
Operation pilot
lamp
Indicates the output
condition of the controller.
ON: The Controller is in
operation under external
control.
Blinking: The Controller is in
forced operation by the
ON/OFF key.
Long OFF and blinking: The
Controller is at a forced
stop by the ON/OFF key.
⑤
Parameter
mode pilot lamp
ON when the parameter
is being set
⑥
Frequency lock
pilot lamp
ON when the frequency is
locked.

10/20
7-2. Display Mode
1) Normal mode
Displays and sets the output voltage, frequency and frequency lock setting on the data display
area.
Upon turning ON the power supply, this display appears.
2) Parameter mode (Pilot lamp ⑤FUNC lights up.)
Shows and sets the parameter on the data display.(Details⇒P.15)
To switch the display mode, press the Func key long for 2 sec.
Regardless of the display mode, operation and stopping through the panel and under the external
control is enabled.
7-3. Setting the Frequency Lock
This setting is enabled when the normal mode (output voltage, frequency) is in display. When the
Func key is pressed, the pilot lamp ⑥F-LOCK starts blinking, and the data display area displays
the current setting.
When the Func key is pressed again, the voltage is displayed.
Voltage (Frequency) →⑥F-LOCK →Voltage
To select the setting, press the Freq▲key or Freq▼key. To execute the setting
change, press the Set key.
When the setting change is completed, the voltage is displayed.
If the process is brought forward to the next item by pressing the Func key without
pressing the Set key during the setting change, the setting will not be changed.
※If there is no key operation for over 5 min, the voltage is displayed.
on : The frequency cannot be changed.
oFF: The frequency can be changed.
7-4. Preparation for Operation
Before powering ON the Controller, recheck the model, specifications and power voltage of the
Controller to confirm no discrepancy, and also recheck the connections to confirm no wrong
connection. Particularly when external signal is used, be careful not to mistake the polarity.

11/20
8. Operation and Amplitude Adjustment Method
P2xx
0.0
Program version
(for 2 sec)
Initial screen:
Output%
①Power ON
The following are displayed in this order:
※Go to <②Adjustment of vibration>.
<Meaning of RUN lamp status>
ON: In operation by remote control
OFF: Operation at a stop (when remote
control is OFF)
Quick blinking: In forced operation
Slow blinking: Forced operation at a stop
* Forced operation means
⇒ Forcedly starting/stopping the operation by
pressing the ON/OFF button whether the
operation is remote-controlled or not
①Data display area
②Frequency pilot lamp
③Voltage% pilot lamp
④Operation pilot lamp
⑤Parameter pilot lamp
⑥Frequency lock pilot lamp
:
ON
:Blinking
:
OFF
<Lamp status>
(A) ON/OFF key
(B) Func key
(C) Set key
(D) Vol▲key
(E) Vol▼key
(F) Freq▲key
(G) Freq▼key
Operation panel

12/20
0.0
30.0
30.0
240.0
150.0
30.0
10.0
150.0
152.0
25.0
ON/OFF
key
※Adjusts the frequency to
the frequency that raises
the parts feeding speed to
the fastest.
At this time, if the vibration
becomes too intensive,
lower the output%.
Vol▲key
②Adjustment of vibration
※Performs the following
in the forced operation.
Freq▲▼ keys
※Switches the output%
setting screen to the
frequency setting screen.
※Switches the frequency
setting screen to the
output% setting screen.
Vol▲▼ keys
※Lowers the output%
until the speed is lowered
to the speed at which the
parts moves slightly.
※Adjusts the output%
to the output% that can
achieve the required
speed.
Vol▲▼ keys
Freq▲▼ keys
※Sets the output% to
approx. 30
-50%
※Adjusts the frequency
to the frequency that can
achieve the best travel of
the parts.
※Switches the output%
setting screen to the
frequency screen.
※Now, the adjustment of
vibration is completed.
Freq▲▼ keys
Vol▲▼ keys
Freq▲▼ keys

13/20
9. Added Function
Soft start and soft stop functions
If the rising time or falling time of the piezo feeder should be adjusted, change the settings of
the soft start or soft stop.
To change the settings, set the relevant parameter accordingly.
Parameter No. 0C: Soft start = The time until the set output is achieved after the operation
starts
Parameter No. 0d:Soft stop = The time until the stop is made from the set output after the
stop conditions are met.
The set time is 0.2-9.9 sec. (The default value is invalid.)
10. Initialization of the Set Data 【Returning to the factory setting】
(1) When the Controller is in the Power-OFF status, power ON the Controller by pressing the
Vol ▲key and the Freq ▼key together. The Controller starts in the initialization mode,
and the data display shows “99” in blinking.
(2)In this status, press the Func key and the Set key together long for over 3 sec. All set data
are reset.
(3) Upon the completion of resetting, the data display shows “99” in lighting.
(4)When the Func key is pressed long for over 2 sec, the Controller starts in the factory setting
status.
So is the case with powering OFF and then powering ON the Controller.
※When the above procedure is taken, all set data of parameter, frequency and voltage are
cleared.

14/20
11. Remote Unit (RCU-3A)
When the remote unit is connected, the output voltage of the Piezo controller can be operated
by remote control.
※The frequency to be used for remote control is the set frequency of the main unit of the
controller.
For details of usage of the remote unit, refer to the instruction manual of Remote Unit
(RCU-3A).
1) Function
Variable voltage input: 3 contacts (Select variable resistance or analog input of 0 –5VDC for
each contact.)
Switching input of variable voltage input: 3 contacts (No-voltage contact input)
2) Connection
Connect the remote unit to the terminal block of the main unit of the Controller Px12.
3) Usage
(1) Set the remote unit to valid (Parameter No. 0L:on).
(2) Set [in1] to hi (Parameter No. 06:hi).
(3) Adjust the amplitude by referring to “8. Operation and Amplitude Adjustment Method.”
※The vibration adjusted here is the maximum value that can be operated by the remote unit.
(4) Start operation.
Operate the start/stop according to the control signal from the remote unit side.
When the start/stop operation is made by using the ON/OFF key of the main unit of the
controller Px12, the input on the remote unit side becomes invalid.

15/20
12. Parameter Setting Method
1) Parameter data setting method
0.0
0C-- 0d-- 0L oF 06 hi
P2xx
06 hi
06 Lo
06 Lo
0.0
Press the
Func key long
for 2 sec.
Set key
Freq▲▼
keys
Set key
Normal mode screen
Blinking
Vol▲▼ keys
Press the
Func key long
for 2 sec.
Parameter mode
screen
The normal
mode screen
reappears.
※
When the Set key is pressed after value setting,
the set value is saved.
※
If the Vol▲▼ keys are pressed without
pressing
the Set key in the change process, the changes
will not be saved but cancelled.
If there is no key operation for over 5 min, the
normal mode screen (voltage display) will be
forced to reappear.
※When the Set key is pressed at the parameter
to be set, the parameter item blinks, and the
parameter value can be changed. Here,
Parameter No. 06 is exemplified.
※When the Vol▲▼ keys are pressed in the parameter mode,
the display of the parameter items shown within the following
frame can be switched:
Vol▲key: Switching 0C →0d → 0L… in this order
Vol▼key: Switching P2xx (Ver. No.) → 06 → 0L… in this
order
Blinking
Vol▲▼ keys

16/20
2) Parameter list
Each time the Vol▲key is pressed, the parameter display switches in the descending order of the
following table. Each time the Vol▼key is pressed, the parameter display switches in the ascending order.
No.
Function
Description
Setting range
Default
value
Change during
operation
0C
Soft start
Output soft start timer
0.2-9.9
--: Invalid
--
○
0d
Soft stop
Output soft stop timer
0.2-9.9
--: Invalid
--
○
0L
Remote Unit
setting
oF: The remote unit is invalid.
on: The remote unit is valid.
oF/on
oF
○
06
in1 setting
in1 Input logic
hi: Operation with the
contact “Close”
Lo: Operation with
the contact “Open
hi
○
Version information
Program version
P2xx
Change during operation: 〇…Enabled, …Disabled
13. Guard and Alert
1) Error display
If an error occurs, the error No. is displayed on the data display, and the output is stopped
forcedly.
Reset the error by either of the following methods (1) and (2).
When resetting the error, eliminate the abnormality beforehand.
If the external signal is an operation condition, be careful that the Controller becomes ready for
operation upon resetting.
(1) Power OFF the Controller, and the error will be reset.
(2) Press the Vol ▼key and the Freq ▼key together long for over 3 sec, and the error will
be reset.
Error No.
Error name
Contents
E-01
Overcurrent error
The output is over the maximum output current.
E-02
Overvoltage error
The output is over than the maximum output voltage.
E-10
Parameter error
Memory error on startup
E-11
Operation data error
Memory error on startup
E-12
System data error
Memory error on startup
2) Alert display
When the Set key is pressed, an alert is displayed.
The output will not stop even during the operation.
If the Controller is continuously used as it is, an error may occur. Therefore, review the settings,
etc.
Alert No.
Alert name
Contents
E-81
Overvoltage alert
The output voltage is the maximum.

17/20
14. Troubleshooting
Trouble
Probable cause
Corrective action
The feeder does not vibrate.
The power cable is not connected.
Connect the power cable.
“Voltage (%)” is “0.0.”
Set “Voltage(%).”
The set frequency is wrong.
Adjust the frequency to the
resonance frequency.
The output connectors is disconnected
from the feeder.
Connect the output connector to
the feeder.
The RUN lamp is OFF.
Check the external control.
Check the parameter settings.
The RUN lamp is blinking.
Press the ON/OFF key
The frequency cannot be
adjusted.
The F-LOCK lamp is ON.
Release the lock.
The overcurrent error (E-01)
is displayed.
The feeder is probably abnormal.
Contact the dealer.
Ground fault was caused due to damage
to the controller output cable cover or
the feeder wire cover.
Replace the damaged cable or wire.
The frequency is deviant.
Adjust the frequency to the
resonance frequency.
One of the memory errors
(E-10 –12) occurs when the
Controller starts.
There was a memory error when the
power supply was turned ON.
Reset the power supply.
If the same error recurs, contact
our sales agent for consultation.
15. Options
Name
Applied wire
Length (mm)
Terminal
Remarks
Power cable
VCTF 0.75x3
1200
Nichifu pin terminal male
PC-2005M
Mounting as
standard
Output cable
VCTFK 0.75x2
1200
Molex terminal
1189ATL
Molex housing 3P
1396R1

18/20
16. Specifications
Model
P212
P312
Input
Voltage
100/230VAC±10%
Frequency
50/60Hz
Number of phases
Single phase
Output
Control method
Sine wave PWM method
Maximum current
50mA
170mA
Voltage
0 - 240VAC
Frequency
50 - 400Hz
Added
function
Operation and stop
Operation and stop enabled according to external signal
(contact or 24VDC)
Others
Soft start, soft stop, short-circuit protection, etc.
Power outlet
24VDC, 160mA
Operating temperature range
0 - 40℃
Operating humidity range
30 - 90% (no condensation)
Place of use
Indoor (no corrosive gas, dust or the like)
Noise resistance
1000Vp or more
Incoming capacity
15VA
26VA
Mass
1.1kg
2.3kg
Applicable
vibrator
Bowl feeder
(Indicated REF- or later model)
90A,120A,150A
110i,150i
190A,230A,300A,
390B,460B
190i
Inline feeder
(Indicated REF- or later model)
L5A,L15A
L25A,L60A,L125A
L30AG,L75AG,L150AG,
L200AG,L250AG
This manual suits for next models
1
Table of contents
Other SANKI Controllers manuals
Popular Controllers manuals by other brands

SEA USA
SEA USA USER 1 24V DG R1 manual

Allen-Bradley
Allen-Bradley 1756-L72EROM installation instructions

TREND
TREND IQ23 Series installation instructions

Chauvet Professional
Chauvet Professional Well Com 2 Quick reference guide

Altronix
Altronix Trove T2ZK7F8 installation guide

Emerson
Emerson Fisher 67D Series instruction manual