Sanuvox SANUVAIR S600 User manual

Sanuvox Technologies Inc, © 2020 All rights reserved. September 2023 EN v.1
Instruction Manual
Photos illustrating products are non contractual.
SANUVAIR®S600
ODOR REDUCTION SYSTEM FOR GARBAGE ROOMS
Commercial Model
Installation Date: _______________ Installed by: _________________
Installer Contact Info.: _________________________________________
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.
Read and follow all instructions contained in the manual before using the product. Read the maintenance instructions before opening the UV unit
or system. Failure to comply with these instructions may result in injuries or damage to the UV unit or system.
NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP.
1. Installation and servicing of UV units or systems (in an
air conditioning system or not) can be hazardous. Only
trained and qualied service personnel should install,
repair or service equipment.
2. Untrained personnel can perform basic maintenance
functions such as replacing lamp(s) and/or lter(s). All
other operations should be performed by trained service
personnel.
3. The unit is not to be used by persons (including children)
with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge.
CAUTION: Unit is not a toy. Keep away from
unsupervised children. Do not leave children unattended
with the unit.
4. DO NOT hang onto the UV unit or system.
5. Some UV units or systems could be heavy: Make sure
you have a minimum of 2 people to safely move or install
these UV units or systems, and make sure you adopt the
most ergonomic position possible (use UV unit or system
handles, if applicable).
CAUTION: Installing or maintaining heavy equipment,
especially overhead, can cause back pain or other injuries.
6. When installing or servicing an overhead UV unit or system,
be careful not to fall off the stepladder. Furthermore, make
sure the UV unit or system latches are always in place to
prevent falling parts.
CAUTION: Some parts of some UV units and systems
may open suddenly if the UV unit or system is installed
high up without its locks.
7. Units that are obviously damaged must not be operated.
8. CAUTION: When working on the UV unit or system,
observe precautions on the literature, tags and labels
attached to the UV unit or system, and all other safety
precautions considered as best practices in the HVAC
industry, if applicable.
9. When applicable, local regulation may comprise more
restrictive installation and/or certication requirements.
The aforementioned requirements prevail on those of this
document and the installer agree to conform to these at his
own expense.
10. Follow all the safety instructions outlined in this document
and respect all local and national codes applicable.
11. All UV units or systems contain a UV-C source. Damage to
the housing or unintended use of the UV unit or system may
result in harmful UV-C leaks. UV-C may, even in little doses,
cause harm to the eyes and skin.
12. Never expose eyes or skin to an operating UV lamp.
Therefore, before installing or performing maintenance
on the UV unit or system, TURN OFF AND DISCONNECT
the UV unit or system from all power sources (there
may be more than one switch to disconnect) and also
disconnect the HVAC system, is applicable.
CAUTION: Electrical shock may cause injuries or
possibly death. FIRST AID INSTRUCTIONS: If injured,
consult a doctor.
13. UV rays may damage certain types of lters (polymer or
plastic); please keep the UV unit or system light away from
shining directly on plastic.
14. When installing or performing maintenance on the UV unit
or system, it is recommended to wear safety gloves. In
order to avoid reduced performance of lamp(s), do not
touch lamp glass without gloves.
15. Just like conventional uorescent lamps, UV lamps contain
a small quantity of mercury: if a lamp breaks, clean and
dispose of with care. UV lamps can be disposed/recycled
after use in the same way as any other uorescent lamps.
Contact and follow the specic instructions of your local
and national authorities.
15.1. Dispose of unit or system according to the specic
instructions and standards of your local and national
authorities.
16. Use only specied SANUVOX branded replacement
UV lamps for your UV unit or system. Use of any other
lamps will void your warranty and can result in damage to
the UV unit or system.
17. Sanuvox UV units or systems are not waterproof. DO NOT
INSTALL OUTDOORS OR IN WET LOCATION unless
specied otherwise.
18. Use of this unit or system supplements, but does not
replace, infection control best practices. Users must follow
all these practices, particularly with regard to cleaning and
disinfecting surfaces.
SAVE THESE INSTRUCTIONS
For any inquiries on a UV unit or system, contact:
Robert Smith
146 Barr St, Saint-Laurent
Quebec, CA, H4T 1Y4
1-888-726-8869
REGISTER
YOUR WARRANTY

2
Instruction Manual for Sanuvair®S600
1-888-726-8869www.sanuvox.com
TABLE OF CONTENTS
IMPORTANT SAFETY INSTRUCTIONS 1
TABLE OF CONTENTS 2
ABOUT THE PRODUCT 3
COMPONENTS 3
How it Works 3
SETUP & INSTALLATION 4
What you will need 4
What’s included 4
Step by Step Installation 4
OPERATION 6
How to Operate your Product 6
MAINTENANCE 6
How to Replace Lamp 6
Step by Step Lamp Replacement 6
How to Clean your Product 7
Step by Step Inlet Filter Cleaning 8
STORAGE 8
ULTRAVIOLETS 8
ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE 8
TROUBLESHOOTING 9
Problems & Solutions Table 9
A. Step by Step Lamp Test 9
WARRANTY 10
CUSTOMER SERVICE 10

A
B
C
DE
F
G
I
K
L
M
H
J
3
Instruction Manual for Sanuvair®S600
1-888-726-8869www.sanuvox.com
ABOUT THE PRODUCT
The Sanuvair®S600 is designed for buildings that struggle with unpleasant odors produced in their trash, recycling or compost
room. Compact and efcient, the Sanuvair®S600 can be installed in less than 30 minutes.
For information or recommendations on how to size your specic application, please call SANUVOX at 1-888-726-8869.
COMPONENTS
How it Works
The Sanuvair® S600 is comprised of a ventilator, fan speed control, a mesh lter, three UV lamps and the cabinet enclosure. The
ventilator pulls air inside the unit through a mesh lter, followed by exposition to the UV lamps, which reduces odors through a
photo-oxydation process. Air is then supplied back to the room.
A. Grill
B. Outlet fan motor
C. Aluminum chamber
D. UV lamp location
E. UV lamps
F. Inlet lter
G. Door contact
H. Fan speed control
I. Lamp ON/OFF toggle switches
J. Access door
K. Handles (one on each side)
L. Power Cord
M. LED indicator for lamp and ballast operation

4
Instruction Manual for Sanuvair®S600
1-888-726-8869www.sanuvox.com
SETUP & INSTALLATION
What you will need
Utility knife, scissors, wire cutters, suitable wall plugs and screws (as needed), screwdriver.
CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack,
install and setup your product. Conrm you have access to the necessary power source for the product requirements (see unit
or system label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869.
What’s included
The SANUVAIR® S600, a mesh lter, three (3) UV lamps and a basic installation kit.
The installation kit includes: a pair of cotton gloves, mounting brackets (2) and a 3-prong power cord with circuit breaker (6').
Step by Step Installation
1. Pick ideal location. Locate a wall that the unit would be mounted on
and where no cause for obstruction will prevent the units airow to run
properly.
The unit should be mounted vertically with the outlet fan position towards
the ceiling and the inlet lter towards the oor.
A minimum clearance of 12" should be left over the unit for adequate
air release. A minimum clearance of 24" should be left under the unit for
adequate air intake.
STEP 1
12" minimum clearance
over the system
24" minimum clearance
under the system
2. Mount system to wall. After measuring the minimum clearance from
the ceiling of the room, mount and install the support bracket horizontally
on the wall with the lip facing the ceiling.
STEP 2

5
Instruction Manual for Sanuvair®S600
1-888-726-8869www.sanuvox.com
3. Using the units handles located on each side of the system, position the
unit on the support bracket and center the unit from left to right.
4. Secure the bottom clamp on the wall where a padlock can be installed
to fasten the unit at the bottom.
5. Install lamps. Open the access door and install the UV lamps on the
connector using the supplied pair of gloves.
When pushing the lamp into the connector, make sure your hand is
holding the ceramic endcap and not the clear quartz part of the lamp
and open the clamp at the same time.
Once the lamp is rmly into position, release the clamp that will hold the
lamp in place.
Proceed the same with the two other lamps.
Your new SANUVAIR®S600
is now ready to operate!
STEP 3
STEP 4
STEP 5

6
Instruction Manual for Sanuvair®S600
1-888-726-8869www.sanuvox.com
OPERATION
How to Operate your Product
The Sanuvair®S600 is a continuously running unit and requires some basic adjustments.
Depending on the air volume of the rooms and the type of waste, light 1, 2 or 3 lamps.
To know the ideal number of lamps for the volume and odor concentration of your room, refer to the calculations previously
provided by Sanuvox when purchasing your Sanuvair®S600.
For information or recommendations on how to size your specic application, please call SANUVOX at 1-888-726-8869.
To adjust the settings of your Sanuvair®S600, move the fan motor rheostat to the desired speed.
If noise is not an issue, it is advisable to set the fan speed to its maximum position.
Finally, close the door, power up the unit by plugging it into a 120V wall outlet.
MAINTENANCE
How to Replace Lamps
Replace UV lamps after one year of use.
Replacing lamps on the Sanuvair®S600 is quick and easy. Simply turn off the power source, open the lamp access door, remove
and dispose of the old lamps, replace them with new Sanuvox branded UV lamps, close the access door and turn the power
source back on. See below for detailed step by step instructions.
CAUTION: In order to avoid reduced performance of lamps, do not touch lamp glass without gloves.
Step by Step Lamp Replacement
STEP 1
1. Unscrew and open the lamp and ballast access door to access the
old lamps.
CAUTION: Before installing or performing maintenance on the unit or
system, TURN OFF AND DISCONNECT the unit or system from all
power sources.
2. Prepare the new lamp. Remove the contents from packaging. Only
after you have visually inspected the UV lamp should you break the
security seal on the underside of the cardboard sleeve. Be sure to
wear the cotton gloves (included) guaranteeing a clean lamp free
from ngerprints. Fingerprints on the lamp will negatively impact the UV
output of the lamp.
NOTE: Fingerprints on the lamp will negatively impact the UV output of
the lamp.
STEP 2

7
Instruction Manual for Sanuvair®S600
1-888-726-8869www.sanuvox.com
3. While holding the new UV lamp by its porcelain end-cap, bring it inside
the unit.
STEP 3
STEP 4
4. Carefully push the four pins of the lamp in the white connector towards
the back of the unit.. The plug is designed so it can only be installed one
way. You may have to rotate the lamp 90° to line up the pins with the
holes.
NOTE: Too much force applied from the opposite end-cap may break
the lamp.
STEP 5
5. Then, slide the porcelain tip through the retention clamp.
Repeat steps 2 to 5 for the two other lamps.
STEP 6
6. Close and screw back the access door.
How to Clean your Product
Maintenance of the unit should be perform at the regular intervals to keep the benets of the UV air purier.
For optimal performance, the lamp should be kept free of dust and residue deposit. Clean when necessary with mild soap or
alcohol. Always spot test the cleaner to make sure it does not damage the surface.
Wash mesh lter every 3 to 6 months or as needed.
Once a year or as needed, clean the interior of the unit (wall and motor plate), with mild non-abrasive soap. It is recommended
to use products that are environmentally friendly.
CAUTION: Under no circumstance should water be sprayed or splashed onto the product.

8
Instruction Manual for Sanuvair®S600
1-888-726-8869www.sanuvox.com
ULTRAVIOLETS
Ultraviolet wavelengths (UV) emitted by Sanuvox units and systems are identical to ultraviolets produced by the sun. UVC
damage nucleic acids (DNA/RNA) of microorganisms, which inactivates them. Unlike conventional UV lamps on the market,
Sanuvox units and systems use a patented process that delivers a maximum dose of UV to the moving air stream or surfaces.
CAUTION: Never expose eyes or skin to an operating UV lamp.
STORAGE
The Sanuvair® S600 unit is xed installation and therefore, requires no specic storage.
ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE
The Sanuvair® S600 has a power consumption of up to 360W. The product is rated at 120/240 VAC, 50/60 Hz and.
See product label to conrm power consumption of your specic unit or system.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY.
DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE
PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST. DOING SO
MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.
Step by Step Inlet Filter Cleaning
1. Open the unit access door: the aluminum inlet air lter is located at the
bottom.
2. Unscrew and remove the thumbscrew from the lter frame to release
the lter.
3. Lift the aluminum lter out of the unit and clean it.
NOTE: The lter can be washed in a mild detergent, soap and water.
4. When lter is dry, reinstall it on the inlet posts.
5. Replace the thumbscrew: place it with your nger and tighten it.
6. Close the access door of your unit.
STEP 3
STEPS 1 & 2
STEP 4
STEP 5

9
Instruction Manual for Sanuvair®S600
1-888-726-8869www.sanuvox.com
TROUBLESHOOTING
If your product is not working properly, refer to the following.
Problem Possible Cause Solution
Unit doesn’t turn ON. - There is no power to the electrical
outlet.
- The door interlock switch is operating.
- Power cord is damaged.
- Test the outlet to make sure there is
power by plugging in another electrical
appliance.
- Check the power cord for damage and
replace if damaged.
- Verify if status light is lit up on the
GFCI plug.
- Press the reset button on the GCFI
plug.
Unit operates only on one speed. - Speed control is defective. - Contact your contractor.
The Red LED (ballast) is lit and the
Amber LED (lamp) is not.
- One of the lamp is defective. - Check the lamp to ensure that it is not
a defect in the lamp sensing circuit in
the ballast. This is done by using an
ohmmeter to check the two laments
on the lamp.
See "A. Step by Step Lamp Test"
instructions below.
- You can also swap lamps with a
working lamp from the unit to validate if
the lamp or the ballast is defective.
Contact your contractor for all your needs in terms of replacement parts:
power cord, motor, ventilator, ballast, UV lamp, etc.
A. Step by Step Lamp Test
1. Disconnect the socket from the lamp.
2. Placing the probe of the ohmmeter to one of the four pins on the
end of the lamp, touch the other probe of the ohmmeter to each of
the other pins until you nd the matching pin.
The ohmmeter will read approximately 3 ohms (almost a short).
This indicates that the lament is good. Check the other two pins.
If both sets of laments test OK, the lamp is functioning.
If one or both sets of laments read an open circuit (innity) on
resistance, the lamp is defective.
STEP 1
STEP 2

10
Instruction Manual for Sanuvair®S600
1-888-726-8869www.sanuvox.com
WARRANTY
You should rst read all instructions before attempting to use this product.
For this warranty to be valid, keep a copy of the proof of purchase.
UV lamp 1 year
Ballast 3 years
Electric Motor 3 years
A. This limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to
damage resulting from abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered
manufacturing defects under this warranty.
SANUVOX IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.
Some jurisdictions do not allow the exclusion or limitation of incidential or consequential damages or limitation on how long an implied warranty last, so
the above limitations or exclusions may not apply to you. This warranty gives specic legal rights, and you also may have other rights which vary from
jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.
B. At its option, SANUVOX will repair or replace this product if it is found to be defective in material or workmanship.
C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.
D. This warranty does not cover the lters, prelters or other accessories (if included), except for material or workmanship defects.
Call us toll-free at 1-888-726-8869 or email: [email protected]
Please be sure to specify product name.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT
TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING
CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.
CUSTOMER SERVICE
TO ORDER REPLACEMENT PARTS
PLEASE CONTACT YOUR CONTRACTOR OR SANUVOX CUSTOMER SERVICE
Toll-Free Phone #: 1-888-726-8869
Email: [email protected]
Website: www.sanuvox.com
Please be sure to specify product name.
Replacement parts for this product
BST120/277GLR 120/277V Multi-Voltage Ballast
LMPHXU65 T6 High Intensity 6.5" UV 'U' lamp
FTR-16 Aluminum mesh lter
WARNING: Use only specied SANUVOX branded replacement UV lamps with your unit or system. Use of any other
lamps will void your warranty and can result in damage to the unit, system and/or lamp(s).
REGISTER
YOUR WARRANTY
ONLINE AT
www.sanuvox.com
Other manuals for SANUVAIR S600
1
Table of contents
Popular Industrial Equipment manuals by other brands

Enerpac
Enerpac WCR4000 instruction sheet

Mitsubishi Electric
Mitsubishi Electric C70 Connection manual

Labounty
Labounty MRX Series Safety, Operation & Maintenance

ABB
ABB A150-M58 Operation manual

dunkermotoren
dunkermotoren BG 75 SI Series instruction manual

Branick
Branick S-FLL Installation, Operation and Repair Parts Information

Doka
Doka Staxo 100 eco Instructions for assembly and use

Husqvarna
Husqvarna 1-8DPF40 Operator's manual

AEMC instruments
AEMC instruments PEL 102 Battery Replacement Procedure

Blohm + Voss Oil Tools
Blohm + Voss Oil Tools VES-HCL 350 Original instructions

Belle
Belle BMD 300 Operator's manual

ITALVIBRAS GIORGIO SILINGARDI
ITALVIBRAS GIORGIO SILINGARDI CDX Series Technical handbook