• Slideofftheendpanelasshownbelow,andslideout
thediffuser.
• Twist90degreesandremovefromslotstoremove.
• Refitbylocatingthepinsinthelampholderslots,
andtwisting90degreestoengagethepinswiththe
contacts.
• Whenchangingabulb,alwaysswitchoffatthemains
andallowthebulbtocoolbeforehandling.
• Usedbulbsshouldnotbedisposedofwithhousehold
waste.Pleaserecyclewherefacilitiesexist.Always
usethecorrecttypeandwattagebulb.Usingthe
incorrectwattagebulbwilldamagethebulband
ballast.
• Reslidethediffuserbackintoposition,andrefitthe
endpanel.
• Replacewith:10785-2x35WT5Fluorescent
Fitting/replacing bulbs Instructionleaflet
Reed
10785
www.saxbylighting.com
Foryoursafety,alwaysswitchoffthesupplybeforechanginglightbulbs,cleaningorremovingshades.
Wasteelectricalproductsshouldnotbedisposedofwithhouseholdwaste.Pleaserecyclewherefacilities
exist.CheckwithyourLocalAuthorityorretailerforrecyclingadvice.
Recycling advice
Safety information
SaxbyLightingLtd.BH233PE
Werecommendcleaningwithasoftdrycloth.
Donotusesolventsorabrasivecleanersasthesecould
damagethefinish.
35W G5 T5
Iss.124062013
Thankyouforpurchasingthislightfitting.Pleasereadtheinstructionscarefullybeforeusetoensuresafeand
satisfactoryoperationofthisproduct.Pleaseretaintheseinstructionsforfuturereference.
Warning
This is a Class 1 product and must be earthed.
Pleasereadtheseinstructionscarefullybefore
commencinganywork.
Thisunitmustbefittedbyacompetentandqualified
electrician.
InstallinaccordancewithIEEWiringregulationsand
currentBuildingRegulations.
Topreventelectrocutionswitchoffatmainssupply
beforeinstallingormaintainingthisfitting.Ensure
otherpersonscannotrestoretheelectricalsupply
withoutyourknowledge.
Thislightfittingshouldbeconnectedtoafusedcircuit.
Ifreplacinganexistingfitting,makeacarefulnoteof
theconnections.
Alwaysusethecorrecttypeandwattagebulb.Using
theincorrectwattagebulbwilldamagethebulband
ballast.
Whenchangingabulb,alwaysswitchoffatthemains
andallowtheoldbulbtocooldownbeforehandling.
Disposeofusedbulbscarefullyandresponsibly.
Thisproductisnotsuitablefordimming.
Wasteelectricalproductsshouldnotbedisposedof
withhouseholdwaste.Pleaserecyclewherefacilities
exist.Checkwithyourlocalauthorityorretailerfor
recyclingadvice.
TheseproductsshouldnotbefittedtoPIRcircuitsor
shortdurationtimedswitches.Shouldyouwishto
connectthisunittoatimedsystempleaseconsultthe
manufacturerbeforeinstallation.
Specification
Voltage: 240V50Hza.c.
Lamp: 10785-2x35WT5Fluorescent

IPrating: 20
Layout
• Planthedesiredlayoutofthisfittingcarefully,
ensuringthecableswillreachthedistancebetween
thejunctionboxandthelightfitting.
• Avoidlocatinganycablesinpositionsthatwould
causeahazard.Positioncablesandjunctionboxes
(notsupplied)awayfromareaswheretheymaybe
atriskfrombeingcut,trappedordamaged.
• Themainssupplycablemusthaveaminimumcross
sectionalareaof1.0mm².
• Ensuretheceilingiscapableofholdingtheweightof
theproduct.
Existingfittingsmustbecompletelyremovedbefore
installationofanewproduct.Beforeremovingthe
existingfittingorceilingrose,carefullynotethe
positionofeachsetofwires.
• Ensurethattheceilingcansupporttheweightofthe
product.
• Drillholes800mmapart,andfitthesupplied
hooksintotheceilingusingthefixingssupplied.
Otherfixingsmayberequired,dependinguponthe
surface.
• Feedthewirethroughthependantnut,andthenthe
decorativecup.Loopthesteelwiresover,asshown,
andsecureusingthewirefixer.
• Hangtheloopoverthehookasshown.Feedthe
supplycablethroughthedecorativecupwiththe
hole.4.Pushthedecorativecupsintoplace.Secure
thesupplycableusingthecablegrips.
• Screweachpendantnutintopositiononthelight
fitting,youmayneedanassistantforthisoperation.
• Removethetopoftheballastcoverbyundoingthe
screwontheside.Feedthewirethroughthehole
attheend,ensuringthatthegrommetiscorrectly
locatedinthehole.
Installation
Wiring
Check that...
• Youhavecorrectlyidentifiedthewires
• Theconnectionsaretight
• Noloosestrandshavebeenleftoutoftheconnection
block.
NEUTRAL
EARTH (GREEN/YELLOW)
SWITCHED LIVE
BLUE (N)
GREEN/YELLOW
BROWN (L)
SUPPLY LIGHT FITTING
Havingcorrectlyidentifiedthewiringfromyourexisting
lightfitting,pullthewirethroughtheholeandconnectto
theconnectionblockinsidetheproductinthefollowing
way:
• Refit the cover into position, and secure using the
screw.
• Replacefuseor circuitbreaker andswitch on.Your
lightisnowreadyforuse.
Commissioning
Supply Cable
Decorative Cup
Wire Fixer
Wire
Cable Grip

Popular Control Unit manuals by other brands

Bosch FLM-420-NAC-D installation guide

Bosch

Bosch FLM-420-NAC-D installation guide

Roger Technology H70/101AC Instructions and Recomendations for the Installer

Roger Technology

Roger Technology H70/101AC Instructions and Recomendations for the Installer

Mitsubishi Electric MELSEC Q Series user manual

Mitsubishi Electric

Mitsubishi Electric MELSEC Q Series user manual

Viessmann VITOSOLIC 100 operating instructions

Viessmann

Viessmann VITOSOLIC 100 operating instructions

GF JRGUMAT troubleshooting guide

GF

GF JRGUMAT troubleshooting guide

MX Atmos Sigma Fitting instructions

MX

MX Atmos Sigma Fitting instructions

A.R.I. D-025 Installation operation & maintenance

A.R.I.

A.R.I. D-025 Installation operation & maintenance

Leviton Verifeye 8000 Series installation guide

Leviton

Leviton Verifeye 8000 Series installation guide

ABB Relion 630 Series quick start guide

ABB

ABB Relion 630 Series quick start guide

Mortara WAM user manual

Mortara

Mortara WAM user manual

Honeywell W7212 Product data

Honeywell

Honeywell W7212 Product data

Fermax AMPLIFIER MODULE CITYMAX quick start guide

Fermax

Fermax AMPLIFIER MODULE CITYMAX quick start guide

M-system R3-NMW1F instruction manual

M-system

M-system R3-NMW1F instruction manual

Siemens SIMATIC 6DL1131-6DF00-0PK0 Equipment manual

Siemens

Siemens SIMATIC 6DL1131-6DF00-0PK0 Equipment manual

A.R.I. Eliptix R-30 S 2W Installation, Operating, Maintenance

A.R.I.

A.R.I. Eliptix R-30 S 2W Installation, Operating, Maintenance

Vertiv Liebert MBSM user manual

Vertiv

Vertiv Liebert MBSM user manual

GSD WXT2CM2511 quick start guide

GSD

GSD WXT2CM2511 quick start guide

isobus CCI A3 operating instructions

isobus

isobus CCI A3 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.