• Slideofftheendpanelasshownbelow,andslideout
thediffuser.
• Twist90degreesandremovefromslotstoremove.
• Refitbylocatingthepinsinthelampholderslots,
andtwisting90degreestoengagethepinswiththe
contacts.
• Whenchangingabulb,alwaysswitchoffatthemains
andallowthebulbtocoolbeforehandling.
• Usedbulbsshouldnotbedisposedofwithhousehold
waste.Pleaserecyclewherefacilitiesexist.Always
usethecorrecttypeandwattagebulb.Usingthe
incorrectwattagebulbwilldamagethebulband
ballast.
• Reslidethediffuserbackintoposition,andrefitthe
endpanel.
• Replacewith:10785-2x35WT5Fluorescent
Fitting/replacing bulbs Instructionleaflet
Reed
10785
www.saxbylighting.com
Foryoursafety,alwaysswitchoffthesupplybeforechanginglightbulbs,cleaningorremovingshades.
Wasteelectricalproductsshouldnotbedisposedofwithhouseholdwaste.Pleaserecyclewherefacilities
exist.CheckwithyourLocalAuthorityorretailerforrecyclingadvice.
Recycling advice
Safety information
SaxbyLightingLtd.BH233PE
Werecommendcleaningwithasoftdrycloth.
Donotusesolventsorabrasivecleanersasthesecould
damagethefinish.
35W G5 T5
Iss.124062013
Thankyouforpurchasingthislightfitting.Pleasereadtheinstructionscarefullybeforeusetoensuresafeand
satisfactoryoperationofthisproduct.Pleaseretaintheseinstructionsforfuturereference.
Warning
This is a Class 1 product and must be earthed.
Pleasereadtheseinstructionscarefullybefore
commencinganywork.
Thisunitmustbefittedbyacompetentandqualified
electrician.
InstallinaccordancewithIEEWiringregulationsand
currentBuildingRegulations.
Topreventelectrocutionswitchoffatmainssupply
beforeinstallingormaintainingthisfitting.Ensure
otherpersonscannotrestoretheelectricalsupply
withoutyourknowledge.
Thislightfittingshouldbeconnectedtoafusedcircuit.
Ifreplacinganexistingfitting,makeacarefulnoteof
theconnections.
Alwaysusethecorrecttypeandwattagebulb.Using
theincorrectwattagebulbwilldamagethebulband
ballast.
Whenchangingabulb,alwaysswitchoffatthemains
andallowtheoldbulbtocooldownbeforehandling.
Disposeofusedbulbscarefullyandresponsibly.
Thisproductisnotsuitablefordimming.
Wasteelectricalproductsshouldnotbedisposedof
withhouseholdwaste.Pleaserecyclewherefacilities
exist.Checkwithyourlocalauthorityorretailerfor
recyclingadvice.
TheseproductsshouldnotbefittedtoPIRcircuitsor
shortdurationtimedswitches.Shouldyouwishto
connectthisunittoatimedsystempleaseconsultthe
manufacturerbeforeinstallation.
Specification
Voltage: 240V50Hza.c.
Lamp: 10785-2x35WT5Fluorescent

IPrating: 20
Layout
• Planthedesiredlayoutofthisfittingcarefully,
ensuringthecableswillreachthedistancebetween
thejunctionboxandthelightfitting.
• Avoidlocatinganycablesinpositionsthatwould
causeahazard.Positioncablesandjunctionboxes
(notsupplied)awayfromareaswheretheymaybe
atriskfrombeingcut,trappedordamaged.
• Themainssupplycablemusthaveaminimumcross
sectionalareaof1.0mm².
• Ensuretheceilingiscapableofholdingtheweightof
theproduct.
Existingfittingsmustbecompletelyremovedbefore
installationofanewproduct.Beforeremovingthe
existingfittingorceilingrose,carefullynotethe
positionofeachsetofwires.
• Ensurethattheceilingcansupporttheweightofthe
product.
• Drillholes800mmapart,andfitthesupplied
hooksintotheceilingusingthefixingssupplied.
Otherfixingsmayberequired,dependinguponthe
surface.
• Feedthewirethroughthependantnut,andthenthe
decorativecup.Loopthesteelwiresover,asshown,
andsecureusingthewirefixer.
• Hangtheloopoverthehookasshown.Feedthe
supplycablethroughthedecorativecupwiththe
hole.4.Pushthedecorativecupsintoplace.Secure
thesupplycableusingthecablegrips.
• Screweachpendantnutintopositiononthelight
fitting,youmayneedanassistantforthisoperation.
• Removethetopoftheballastcoverbyundoingthe
screwontheside.Feedthewirethroughthehole
attheend,ensuringthatthegrommetiscorrectly
locatedinthehole.
Installation
Wiring
Check that...
• Youhavecorrectlyidentifiedthewires
• Theconnectionsaretight
• Noloosestrandshavebeenleftoutoftheconnection
block.
NEUTRAL
EARTH (GREEN/YELLOW)
SWITCHED LIVE
BLUE (N)
GREEN/YELLOW
BROWN (L)
SUPPLY LIGHT FITTING
Havingcorrectlyidentifiedthewiringfromyourexisting
lightfitting,pullthewirethroughtheholeandconnectto
theconnectionblockinsidetheproductinthefollowing
way:
• Refit the cover into position, and secure using the
screw.
• Replacefuseor circuitbreaker andswitch on.Your
lightisnowreadyforuse.
Commissioning
Supply Cable
Decorative Cup
Wire Fixer
Wire
Cable Grip

Popular Control Unit manuals by other brands

Beckmann EMS-8 -DU Series user manual

Beckmann

Beckmann EMS-8 -DU Series user manual

ICP DAS USA tM-TH8 user manual

ICP DAS USA

ICP DAS USA tM-TH8 user manual

ATEN CN8000 user manual

ATEN

ATEN CN8000 user manual

Edwards TCU 40/80 instruction manual

Edwards

Edwards TCU 40/80 instruction manual

Hitachi CH-6.0N2 Installation and operation manual

Hitachi

Hitachi CH-6.0N2 Installation and operation manual

Swegon TBLZ-1-66 installation instructions

Swegon

Swegon TBLZ-1-66 installation instructions

Emerson Keystone Figure 637 Installation and commissioning instructions

Emerson

Emerson Keystone Figure 637 Installation and commissioning instructions

Bosch FLM-I 420-S Product description/Installation manual

Bosch

Bosch FLM-I 420-S Product description/Installation manual

V2 LUX2+ manual

V2

V2 LUX2+ manual

Burkert ME44 quick start

Burkert

Burkert ME44 quick start

Wurth Elektronik CALYPSO Reference manual

Wurth Elektronik

Wurth Elektronik CALYPSO Reference manual

JETStream 53905 Product instructions

JETStream

JETStream 53905 Product instructions

Watts LFM116-31 Installation operation & maintenance

Watts

Watts LFM116-31 Installation operation & maintenance

HydroAir 20-0242 quick start guide

HydroAir

HydroAir 20-0242 quick start guide

Det-Tronics Eagle Quantum Premier EQ3760ASM manual

Det-Tronics

Det-Tronics Eagle Quantum Premier EQ3760ASM manual

HKS Super SQV IV 71008-AK001 manual

HKS

HKS Super SQV IV 71008-AK001 manual

Nice A3 instruction manual

Nice

Nice A3 instruction manual

Waeco AirConServiceCenter ASC5300G operating manual

Waeco

Waeco AirConServiceCenter ASC5300G operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.