Saxby Lighting 90974 User manual

www.saxbylighting.com
Instruction manual
90974, 90975
PIR SECURITY DETECTOR WALL
PIR Adjustment
Saxby Lighting. BH17 7BY
V1 16/10/2019
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
For your safety, always switch off the power supply before changing lightbulbs, or cleaning.
Care and Safety
Technical data
Conformity with all relevant EC Directive requirements.
The power supply is Double Insulated and does not require connection to an Earth circuit.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities
exist. Check with your Local Authority or local store for recycling advice.
This product is rated at IP44.
IP
44
This product is not suitable for dimming.
90974
90975
Supply Voltage: 240V~ Detection Range: 180º
Power Frequency: 50Hz Detection Distance: Max.12m (<24ºC)
Ambient Light: <10-2000LUX (adjustable) Working Temperature: -20~+40ºC
Time Delay: Min.10sec±3sec Working Humidity: <93%RH
Max.7min±2min Power Consumption: approx 0.5W
Rated Load: Max.2000W Installation Height: 1.8-2.5m
1000W Detection Moving Speed: 0.6-1.5m/s
TIME LUX
TIME LUX
• Turn the TIME knob anti-clockwise on the minimum (10s). Turn the LUX knob
clockwise on the maximum (sun).
• Switch on the power, the sensor and its connected lamp will have no
signal at the beginning. After Warm-up 30sec, the sensor can start work.
If the sensor receives the induction signal, the lamp will turn on. While there
is no another induction signal any more, the load should stop working within
10sec±3sec and the lamp would turn off.
• Turn LUX knob anti-clockwise on the minimum (moon). If the ambient light is
more than 10LUX, the sensor would not work and the lamp stop working too. If
the ambient light is less than 10LUX (darkness), the sensor would work. Under
no induction signal condition, the sensor should stop working
within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position,
otherwise the sensor lamp could not work!
Warning
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Installation
This product is double insulated and does
not require connection to an Earth circuit.
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully
note the position of each set of wires.
Note that the switch is turned off before installation.
Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.
After deciding the layout of the light fittings ensure that the cables are long enough to connect to desired positions.
• Undo the screw at the bottom of the product to separate the rear panel from product.Keep screw in safe place for
refitting later.
• If you wish to pass the mainscable through the rearpanel, drill throughthe cable entry hole (bottom right when rear
panel is attached to wall) and make sure therubber grommet supplied in the fixing pack is in place to ensure ingress
protection. Alternatively, the mains cable can bepassed through thecable entry hole on the undersideof the product.
Again, use the supplied grommet to ensureingressprotection.
• Using the rear panel as a template, mark and drill the fixing holes (diagonally positioned). The fixing holes are marked out in
the rear panel-drill through them too. Make sure the rear panel is correctly oriented with the straight edge at the bottom.
Take care to avoid damaging any concealed wiring or pipes.
• Fix the bottom with inflated screw on the selected position. install back the sensor on the bottom,
tighten the screw and then test it.
• Wire as detailed below.
Having correctly identified the wiring from your existing light fitting and connect to the connection block inside the product in
the following way:
Wiring
Check that...
You have correctly identified the wires
The connections are tight
Layout
This product is designed for optimum performance when mounted 1.8-2.5m above the ground.
Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.
Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, light etc.
Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.
The mains supply cable must have a minimum cross section area of 1.0mm2.
Cables must be protected using suitable conduit or plastic trunking.
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons cannot
restore the electrical supply without your knowledge.
If you are in any doubt, please consult a qualified electrician.
If replacing an existing fitting, make a careful note of the connections.
This unit should be connected to a fused circuit.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice.
This product is double insulated and must not be earthed. If there are any incoming earth cables, they must be joined together
and well insulated with good quality insulation tape. This is to ensure earth continuity throughout your property.
No loose strands have been left out of the connection block
The cable clamp is fitted over the wires.
IN O UT
L N
IN~
OUT~
LOAD
L(BROWN)
N(BLUE)
A(RED)
PIR

This manual suits for next models

1

Other Saxby Lighting Security Sensor manuals

Saxby Lighting 95283 User manual

Saxby Lighting

Saxby Lighting 95283 User manual

Saxby Lighting 90978 User manual

Saxby Lighting

Saxby Lighting 90978 User manual

Saxby Lighting PIR MINI User manual

Saxby Lighting

Saxby Lighting PIR MINI User manual

Saxby Lighting 90977 User manual

Saxby Lighting

Saxby Lighting 90977 User manual

Popular Security Sensor manuals by other brands

Reer VISION V3BL instructions

Reer

Reer VISION V3BL instructions

GJD Opal XL installation manual

GJD

GJD Opal XL installation manual

Sewosy DMV2CBL User instructions

Sewosy

Sewosy DMV2CBL User instructions

Ecolink Firefighter FF-ZWAVE5 installation manual

Ecolink

Ecolink Firefighter FF-ZWAVE5 installation manual

Net Safety UV/IRS-A user manual

Net Safety

Net Safety UV/IRS-A user manual

Honeywell 748LC Product guide

Honeywell

Honeywell 748LC Product guide

Sperian Miller Scorpion User instruction manual

Sperian

Sperian Miller Scorpion User instruction manual

Theben theRonda S360 KNX UP WH instructions

Theben

Theben theRonda S360 KNX UP WH instructions

Detection Systems DS7060 quick start guide

Detection Systems

Detection Systems DS7060 quick start guide

LEGRAND EMOS G1210 manual

LEGRAND

LEGRAND EMOS G1210 manual

roco Z21 10808 manual

roco

roco Z21 10808 manual

Feig Electronic VEK M2E-2-B operating instructions

Feig Electronic

Feig Electronic VEK M2E-2-B operating instructions

Everflourish G-Homa RF302PIR instruction manual

Everflourish

Everflourish G-Homa RF302PIR instruction manual

Coster RFG 749 manual

Coster

Coster RFG 749 manual

Niko Swiss Garde 300 Prasenz UP Max installation instructions

Niko

Niko Swiss Garde 300 Prasenz UP Max installation instructions

Infineon XENSIV DPS310 Kit2Go user guide

Infineon

Infineon XENSIV DPS310 Kit2Go user guide

Renkforce 1296294 operating instructions

Renkforce

Renkforce 1296294 operating instructions

ST X-NUCLEO-IKS02A1 user manual

ST

ST X-NUCLEO-IKS02A1 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.