Warning
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Installation
This product is double insulated and does
not require connection to an Earth circuit.
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully
note the position of each set of wires.
Note that the switch is turned off before installation.
Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.
After deciding the layout of the light fittings ensure that the cables are long enough to connect
to desired positions.
• Using the plastic base as a template, mark and drill the fixing holes. Fix the plastic base
on the selected position with the screws. Take care to avoid damaging any concealed
wiring or pipes. ( If you need, you can separate the the sensor from the plastic base befor
installing. The sensor and plastic base is a whole when leaving factory.)
• Connect the power wire with the sensor according to the wire diagram below:
• Switch on the power and test it.
Having correctly identified the wiring from your existing light fitting and connect to the connection block inside the product in
the following way:
Wiring
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons cannot
restore the electrical supply without your knowledge.
If you are in any doubt, please consult a qualified electrician.
If replacing an existing fitting, make a careful note of the connections.
This unit should be connected to a fused circuit.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice.
This product is double insulated and must not be earthed. If there are any incoming earth cables, they must be joined together
and well insulated with good quality insulation tape. This is to ensure earth continuity throughout your property.
Check that...
You have correctly identified the wires
The connections are tight
No loose strands have been left out of the connection block
The cable clamp is fitted over the wires
Layout
The mains supply cable must have a minimum cross section area of 1.0mm2.
Cables must be protected using suitable conduit or plastic trunking.
Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.
Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, light etc.
Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.
It not only can install on the wall directly but also can install on ceiling, the installation height and the detection distance
refer to photographo below:
Height of installation: 1.8-2.5m Detection Distance: Max.10m Height of installation: 2.2-4m Detection Distance: Max.6m
L N
IN~
OUT~
LOAD
L(BROWN)
N(BLUE)
A(RED)
PIR