Instruction manual
95284
PIR MINI
PIR Adjustment
Saxby Lighting. BH17 7BY
V1 27/11/2020
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
For your safety, always switch off the power supply before changing lightbulbs, or cleaning.
Care and Safety
Technical data
Conformity with all relevant CE Directive requirements.
The power supply is Double Insulated and does not require connection to an Earth circuit.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities
exist. Check with your Local Authority or local store for recycling advice.
Supply Voltage: 240V~ Detection Range: 120º / 360º
Power Frequency: 50Hz Detection Distance: 2-10m (<24ºC)(adjustable)
Ambient Light: <10-2000LUX (adjustable) Working Temperature: -20~+40ºC
Time Delay: Min.10sec±3sec Working Humidity: <93%RH
Max.7min±2min Installation Height: Wall mount 1.8-2.5m / Ceiling mount 2.2-4m
Rated Load: Max.100W Detection Moving Speed: 0.6-1.5m/s
100W
• Turn the SENS knob clockwise on the maximum (+). Turn the LUX knob clockwise on the maximum (sun). Turn the TIME
knob anti-clockwise on the minimum (-).
• Switch on the power, the sensor and its connected lamp will have no signal at the beginning. After Warm-up 30sec, the
sensor can start work. If the sensor receives the induction signal, the lamp will turn on.
While there is no another induction signal any more, the load should stop working
within 10sec±3sec and the lamp would turn off.
• Turn LUX knob anti-clockwise on the minimum (moon). If the ambient
light is more than 10LUX, the sensor would not work and the lamp stop
working too. If the ambient light is less than 10LUX (darkness), the
sensor would work. Under no induction signal condition, the sensor
should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position,
otherwise the sensor lamp could not work!
If the lamp is more than 60W, the distance between lamp and sensor should be 60cm at least.
Warning
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Installation
This product is double insulated and does
not require connection to an Earth circuit.
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully
note the position of each set of wires.
Note that the switch is turned off before installation.
Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.
After deciding the layout of the light fittings ensure that the cables are long enough to connect
to desired positions.
• Using the plastic base as a template, mark and drill the fixing holes. Fix the plastic base
on the selected position with the screws. Take care to avoid damaging any concealed
wiring or pipes. ( If you need, you can separate the the sensor from the plastic base befor
installing. The sensor and plastic base is a whole when leaving factory.)
• Connect the power wire with the sensor according to the wire diagram below:
• Switch on the power and test it.
Having correctly identified the wiring from your existing light fitting and connect to the connection block inside the product in
the following way:
Wiring
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons cannot
restore the electrical supply without your knowledge.
If you are in any doubt, please consult a qualified electrician.
If replacing an existing fitting, make a careful note of the connections.
This unit should be connected to a fused circuit.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice.
This product is double insulated and must not be earthed. If there are any incoming earth cables, they must be joined together
and well insulated with good quality insulation tape. This is to ensure earth continuity throughout your property.
Check that...
You have correctly identified the wires
The connections are tight
No loose strands have been left out of the connection block
The cable clamp is fitted over the wires
Layout
The mains supply cable must have a minimum cross section area of 1.0mm2.
Cables must be protected using suitable conduit or plastic trunking.
Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.
Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, light etc.
Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.
It not only can install on the wall directly but also can install on ceiling, the installation height and the detection distance
refer to photographo below:
Height of installation: 1.8-2.5m Detection Distance: Max.10m Height of installation: 2.2-4m Detection Distance: Max.6m
L N
IN~
OUT~
LOAD
L(BROWN)
N(BLUE)
A(RED)
PIR

This manual suits for next models

1

Other Saxby Lighting Security Sensor manuals

Saxby Lighting 90977 User manual

Saxby Lighting

Saxby Lighting 90977 User manual

Saxby Lighting 95283 User manual

Saxby Lighting

Saxby Lighting 95283 User manual

Saxby Lighting 90978 User manual

Saxby Lighting

Saxby Lighting 90978 User manual

Saxby Lighting 90974 User manual

Saxby Lighting

Saxby Lighting 90974 User manual

Popular Security Sensor manuals by other brands

Theben PlanoSpot 360 DALI-2 S DE Series manual

Theben

Theben PlanoSpot 360 DALI-2 S DE Series manual

Crow SWAN QUAD installation instructions

Crow

Crow SWAN QUAD installation instructions

DeWalt DW0892G instruction manual

DeWalt

DeWalt DW0892G instruction manual

steute Ex RC Si M30-3G/D Mounting and wiring instructions

steute

steute Ex RC Si M30-3G/D Mounting and wiring instructions

CST/BERGER LASERMARK LLD20 Original instructions

CST/BERGER

CST/BERGER LASERMARK LLD20 Original instructions

Fracarro DT1000AM quick start guide

Fracarro

Fracarro DT1000AM quick start guide

SubSurface Instruments PL-2000 Operation manual

SubSurface Instruments

SubSurface Instruments PL-2000 Operation manual

Westfalia EM0328 instruction manual

Westfalia

Westfalia EM0328 instruction manual

SICK Prime KTS-WB9A34115A Series manual

SICK

SICK Prime KTS-WB9A34115A Series manual

Wieland gesis P MS8-360-1L installation instructions

Wieland

Wieland gesis P MS8-360-1L installation instructions

Electro Detectors EDA-D5000 installation instructions

Electro Detectors

Electro Detectors EDA-D5000 installation instructions

ABB AquaProbe FEA200 user guide

ABB

ABB AquaProbe FEA200 user guide

ScienTECH AC2500 operating manual

ScienTECH

ScienTECH AC2500 operating manual

Bosch D-tect 150 Professional Original instructions

Bosch

Bosch D-tect 150 Professional Original instructions

Hanna 1200 user manual

Hanna

Hanna 1200 user manual

Lufft SHM 31 user manual

Lufft

Lufft SHM 31 user manual

SICK KTX Prime manual

SICK

SICK KTX Prime manual

Satel SLIM-DUAL manual

Satel

Satel SLIM-DUAL manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.