•Voltage: 220-240V~50Hz
• Wattage: Maximum Load Wattage: 1600W incandescent bulb, 500W fluorescent bulb.
• Detection range: 360o over a detection field of 12m diameter at 3m distance.
• Duration time: From 10±5 seconds to 4±1 minutes adjustable
•Lux control level: From daylight to total darkness
Thank you for purchasing this light fitting.
Please read the instructions carefully before use to ensure safe and satisfactory operation of this product.
Please retain these instructions for future reference.
Warning
Layout
• Thisproductissuitableformountinginaceiling.
The optimum mounting distances are shown in the
diagram on the right.
• Avoidpointingatorpositioningclosetoheat
sources such as flues or heat extraction units, which
may cause false triggering.
• Avoidpointingatbrightlightsasunitwillnot
function when you set Lux control level to dark
• Avoidlocatingnearelectromagneticfields
Installation
• Detachthefrontbezelfromtheproductbyremoving
the small screw on the side of the unit and twisting
anticlockwise. keep the bezel and screw safe for
refitting later.
• Usingtheceilingcoverasatemplate,markand
drill the fixing holes using appropriate fixings for the
mounting surface. Take care to avoid damaging any
concealed wiring or pipes.
• Removethecableclamp(A)toaccesstheterminal
block.
• Wireasdetailedbelow.
This product is Double Insulated and does
not require connection to an Earth circuit.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure
other persons cannot restore the electrical supply
without your knowledge.
This unit should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of
the connections.
This product is not suitable for dimming.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.
This unit is only suitable for indoor use.
This product is double insulated and must not be
earthed. If there are any incoming earth cables, they
must be joined together and well insulated with good
quality insulation tape. This is to ensure earth continuity
throughout your property.
Having correctly identified the wiring from your existing
light fitting and connect to the connection block inside
the product in the following way:
Wiring
Check that...
• You have correctly identified the wires.
• The connections are tight.
• No loose strands have been left out of the connection
block.
L in (Mains Live input) L out - Brown (Live output feed
to the lights to be controlled)
N in (Mains Neutral input) N out - Blue (Neutral output
feed)