Instruction leaflet
PIR Sensor
54413
We recommend cleaning with a soft dry cloth.
Do not use solvents or abrasive cleaners as these could damage the finish.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities
exist. Check with your Local Authority or retailer for recycling advice.
Recycling advice
Safety information
Iss.1 23062015
Care and Cleaning
For your safety, always switch off the supply before changing lightbulbs, or cleaning.
PIR Adjustment
The PIR sensor has a fixed detection field of 12m
diameter at a distance of 3m. It can be adjusted for
duration the lamp stays on ("TIME" screw) and the
light level that the switch activates ("LUX" screw).
To adjust when the switch activates, rotate the "LUX"
screw between the sun and moon symbols. sun
indicates the PIR sensor will operate at all times
during daylight and darkness. moon indicates that the
PIR sensor will operate in total darkness only.
To adjust the duration the lamp stays on, rotate the
"TIME" screw between + and - . Minimum time on
is 10+/-5 seconds maximum time on is 4+/- 1
minutes
•Voltage: 220-240V~50Hz
• Wattage: Maximum Load Wattage: 1600W incandescent bulb, 500W fluorescent bulb.
• Detection range: 360o over a detection field of 12m diameter at 3m distance.
• Duration time: From 10±5 seconds to 4±1 minutes adjustable
•Lux control level: From daylight to total darkness
Thank you for purchasing this light fitting.
Please read the instructions carefully before use to ensure safe and satisfactory operation of this product.
Please retain these instructions for future reference.
Warning
Layout
• Thisproductissuitableformountinginaceiling.
The optimum mounting distances are shown in the
diagram on the right.
• Avoidpointingatorpositioningclosetoheat
sources such as flues or heat extraction units, which
may cause false triggering.
• Avoidpointingatbrightlightsasunitwillnot
function when you set Lux control level to dark
• Avoidlocatingnearelectromagneticfields
Installation
• Detachthefrontbezelfromtheproductbyremoving
the small screw on the side of the unit and twisting
anticlockwise. keep the bezel and screw safe for
refitting later.
• Usingtheceilingcoverasatemplate,markand
drill the fixing holes using appropriate fixings for the
mounting surface. Take care to avoid damaging any
concealed wiring or pipes.
• Removethecableclamp(A)toaccesstheterminal
block.
• Wireasdetailedbelow.
This product is Double Insulated and does
not require connection to an Earth circuit.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure
other persons cannot restore the electrical supply
without your knowledge.
This unit should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of
the connections.
This product is not suitable for dimming.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.
This unit is only suitable for indoor use.
This product is double insulated and must not be
earthed. If there are any incoming earth cables, they
must be joined together and well insulated with good
quality insulation tape. This is to ensure earth continuity
throughout your property.
Having correctly identified the wiring from your existing
light fitting and connect to the connection block inside
the product in the following way:
Wiring
Check that...
• You have correctly identified the wires.
• The connections are tight.
• No loose strands have been left out of the connection
block.
L in (Mains Live input) L out - Brown (Live output feed
to the lights to be controlled)
N in (Mains Neutral input) N out - Blue (Neutral output
feed)
360°
House Ceiling
Radius
Figure 2
Max 6M Max 6M
A
Commissioning
• Refitthecableclampandsensorcover.
• AdjustthePIRsensorasdetailedoverleafandrefit
the front bezel and securing screw.
• Replacefuse orcircuitbreaker andswitch on.Your
light is now ready for use.
Specification

Other Saxby Accessories manuals

Saxby 54414 Manual

Saxby

Saxby 54414 Manual

Saxby 67346 Manual

Saxby

Saxby 67346 Manual

Saxby 73716 Manual

Saxby

Saxby 73716 Manual

Popular Accessories manuals by other brands

Philips T20 specification

Philips

Philips T20 specification

Craftsman 316.792420 Operator's manual

Craftsman

Craftsman 316.792420 Operator's manual

MS Sedco DH400 installation instructions

MS Sedco

MS Sedco DH400 installation instructions

SMC Networks XT477-4-X2 instruction manual

SMC Networks

SMC Networks XT477-4-X2 instruction manual

The Siemon Company S210 instructions

The Siemon Company

The Siemon Company S210 instructions

Tait TB9100 Installation and operation manual

Tait

Tait TB9100 Installation and operation manual

GSE 574 Technical reference manual

GSE

GSE 574 Technical reference manual

esera 1-Wire Multisensor Pro II user guide

esera

esera 1-Wire Multisensor Pro II user guide

Siemens Bently Nevada 3500 Proximitor Maintenance and troubleshooting

Siemens

Siemens Bently Nevada 3500 Proximitor Maintenance and troubleshooting

Videosec RF-YKCZ-EU-220 instruction manual

Videosec

Videosec RF-YKCZ-EU-220 instruction manual

APLIC 304433 user manual

APLIC

APLIC 304433 user manual

Huawei DDSU666-H user manual

Huawei

Huawei DDSU666-H user manual

Joy-it KY-001 user manual

Joy-it

Joy-it KY-001 user manual

ekwb EK-FB ASUS Maximus XI HERO installation manual

ekwb

ekwb EK-FB ASUS Maximus XI HERO installation manual

Lambrecht METEOROLOGY 14576-24 V operating instructions

Lambrecht

Lambrecht METEOROLOGY 14576-24 V operating instructions

MITECH GEMINI Series Installation and user manual

MITECH

MITECH GEMINI Series Installation and user manual

NOW Solutions 7483 Instructions & Care

NOW Solutions

NOW Solutions 7483 Instructions & Care

IFM Electronic Efector160 LK3 operating instructions

IFM Electronic

IFM Electronic Efector160 LK3 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.