•Voltage: 220-240V~50Hz
• Wattage: Maximum Load Wattage: 1000W incandescent bulb, 300W fluorescent bulb.
• Detection range: Approximately 180o (horizontal) & 60o (vertical) over a detection field of 12m
• Duration time: From 10±5 seconds to 4±1 minutes adjustable
•Lux control level: From daylight to total darkness
•IP Rating:44
Thank you for purchasing this light fitting.
Please read the instructions carefully before use to ensure safe and satisfactory operation of this product.
Please retain these instructions for future reference.
Warning
Layout
• Thisproductisdesignedforoptimumperformance
when mounted 2.5m above the ground.
• Avoidpositioningneartotreesorshrubswhichmay
cause false triggering during inclement weather.
• Avoidpointingatorpositioningclosetoheat
sources such as flues or heat extraction units, which
may cause false triggering.
• Avoidpointingatbrightlightsasunitwillnot
function when you set Lux control level to dark
• Avoidlocatingnearelectromagneticfields
Installation
• Undothescrewatthebottomoftheproducttodetachthewallback.Keepscrewinsafeplaceforrefittinglater.
• Usingthewallbackasatemplate,markanddrillthefixingholes(diagonallypositioned).Thefixingholesare
marked out in the wall back - drill through them too. Make sure the wall back is correctly oriented with the
straight edge at the bottom. Take care to avoid damaging any concealed wiring or pipes.
• Ifyouwishtopassthemainscablethroughthewallback,drillthroughthecableentryhole(bottomright
when wall back is attached to wall) and make sure the rubber grommet supplied in the fixing pack is in place
to ensure ingress protection. Alternatively, the mains cable can be passed through the cable entry hole on the
underside of the product. Again, use the supplied grommet to ensure ingress protection.
• Wireasdetailedbelow.
This product is Double Insulated and does
not require connection to an Earth circuit.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure
other persons cannot restore the electrical supply
without your knowledge.
This unit should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of
the connections.
This product is not suitable for dimming.
This product is rated at IP44.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.
This product is double insulated and must not be
earthed. If there are any incoming earth cables, they
must be joined together and well insulated with good
quality insulation tape. This is to ensure earth continuity
throughout your property.
Having correctly identified the wiring from your existing
light fitting and connect to the connection block inside
the product in the following way:
Wiring
Check that...
• Youhavecorrectlyidentifiedthewires.
• The connections are tight.
• No loose strands have been left out of the connection
block.
• The cable clamp is fitted over the wires.
Specification
(MAINS) L
(MAINS) N
(LAMP) L
BROWN (PIR)
BLUE (PIR)
BLACK(PIR)
SUPPLY PRE-FITTED
(LAMP) N