Scaime eNodTouch-M User manual

NU-eNodTouchM-E-0815_196774-B
SCAIME SAS – Technosite Altéa –BP501- 74105 ANNEMASSE Cedex
Tél. : +33 (0)4 50 87 78 64 – www.scaime.com
eNodTouch-M
Touch screen for multiple eNod4 controllers
User Manual

2
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
Contents
1. Hardware................................................................................................................................3
1.1. Presentation ..........................................................................................................3
1.2. Dimensions............................................................................................................5
1.2.1. eNodTouch M.....................................................................................5
1.2.2. eNodTouch ML ...................................................................................6
1.3. Installation.............................................................................................................7
1.3.1. Installation requirements...................................................................7
1.3.2. eNodTouch installation......................................................................8
1.4. Electrical powering ............................................................................................10
1.5. RS485 interface for connection to eNod4........................................................11
2. Off-Line setting.....................................................................................................................12
2.1. Entering Offline mode ........................................................................................12
2.2. Offline mode operations....................................................................................13
2.2.1. Main unit Menu ................................................................................13
2.2.2. Brightness/contrast control.............................................................14
2.2.3. Peripheral – Device PLC Settings....................................................14
2.2.4. Password menu................................................................................14
2.2.5. Initialize menu..................................................................................14
2.2.6. Maintenance menu.........................................................................15
3. On-Line Functioning............................................................................................................16
3.1. Startup screens ...................................................................................................16
3.2. Multi-eNod screens............................................................................................17
3.2.1. Increase eNod number...................................................................17
3.2.2. Select an eNod ................................................................................19
3.2.3. Communication error and disconnection.....................................20
3.3. Main screen ........................................................................................................21
3.3.1. Transmitter mode (eNod4-T)...........................................................21
3.3.2. Checkweigher mode (eNod4-C)...................................................22
3.3.3. Dosing mode (eNod4-D).................................................................23
3.3.4. Keyboard functions .........................................................................24
3.4. Result displaying and storage (eNod4-C, eNod4-D)......................................25
3.5. Main setup menu................................................................................................27
3.5.1. eNodTouch setup.............................................................................28
3.5.2. Starting Parameters..........................................................................28
3.5.3. Calibration setup..............................................................................29
3.5.4. I/O Setup...........................................................................................32
3.5.5. Configuration Setup.........................................................................35
3.5.6. Function mode setup (eNod4-C & eNod4-D)...............................38
3.6. Checkweigher Setup menu (eNod4-C)...........................................................39
3.7. Dosing Setup menu (eNod4-D).........................................................................42
3.7.1. Dosing Cycle Setup .........................................................................42
3.7.2. Starting conditions setup.................................................................44
3.7.3. Dosing Timing Setup.........................................................................45
3.7.4. In-flight correction Settings.............................................................46
3.7.5. Flow rate control settings ................................................................47
3.7.6. Dosing Tolerance control................................................................47
3.8. Dosing Target values..........................................................................................48
3.9. Configuration of Quick Access menu..............................................................49

3
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
1. Hardware
1.1. Presentation
eNodTouch, is a compact graphic operator interface with the following specifications:
Display type 3.5” TFT Color LCD
Resolution W320 x H240 pixels
Display area W72 x H52 mm
Display colours 65536 colors
Backlight None
Brightness / Contrast 16 levels
Touch Panel type Analog resistive film
Touch panel service life 1,000,000 times or more
Input voltage 24VDC, 6.5W or less
Rated voltage DC 20.4 to 28.8V
Insulation resistance DC 500V, 10MΩ
Grounding Grounding resistance of 100Ω
Dimension W97.6 x H79.5 x D31.5 mm
Weight 0,36 kg approx.
Surrounding air temperature 0 to +50°C
Ambient humidity
85 % RH (Wet bulb temperature: 39 ℃or less - no condensation.)
Dust 0.1 mg/m³ or less (non-conductive levels)
Storage temperature -20 to +60°C
Structure IP65, on the front panel when properly installed in an enclosure
Cooling method Natural air circulation
Serial Interface COM1 RS-422/485, Asynchronous Transmission, Data Length: 7 or 8 bit,
Parity: none, Odd or Even, Stop Bit: 1 or 2 bit, Data Transmission
Speed: 2,400 bps to 115.2 kbps, Communication Distance: 30 m or
less
USB1 interface Conforms to USB2.0 (Type A), Power Supply Voltage: DC 5 V ±5 %,
Communication Distance: 5 m or less
USB2 interface Conforms to USB2.0 (mini-B), Communication Distance: 5 m or less

4
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
(A) USB Interface (Type A) (USB1)
(B) Serial Interface (COM1)
(C) Ethernet Port
(D) Supply connector
(E) USB Interface (mini B) (USB2)

5
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
1.2. Dimensions
1.2.1. eNodTouch M

6
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
1.2.2. eNodTouch ML

7
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
1.3. Installation
1.3.1. Installation requirements
•For easier maintenance, operation, and improved ventilation, be sure to install eNodTouch at least 100mm [3.94in.]
away from adjacent structures and other equipment.
•Be sure that the surrounding air temperature and the ambient humidity are within their designated ranges.
(Surrounding air temperature: 0 to 50°C, Ambient humidity: 85% RH, Wet bulb temperature: 39°C max.) When installing
eNodTouch on the panel of a cabinet or enclosure, “Surrounding air temperature” indicates both the panel face and
cabinet or enclosure’s internal temperature.
•The panel should not be inclined more than 30°.

8
User manual SCAIME:
NU-eNodTouchM-E-0815_196774-B
1.3.2. eNodTouch installation
Panel cut dimensions:
Without Anti-rotation Tee
With Anti-rotation Tee
A (mm)
B (mm) (1)
B (mm) (2)
C (mm)
D (mm)
22.5 (tolerance -0.30)
1.5 à 6
3 à 6
30 (tol -0.20)
4 (tol -0.20)
(A) Diameter of the cut
(B) Thickness of the panel
(1) Material of the panel : Steel
(2) Material of the panel : Glass fiber reinforced
Installation procedure :
Step
Action
1
Place the unit on a clean and level surface with the display panel facing downward.
2
Cut a panel with the specified thickness in function of the material.
3
Create the correct sized hole with a diameter of 22.5mm (tol -0.30) on the panel.
4
Insert the display module following the illustration :
Screw the nut with the socket wrench with a torque between 1.2 and 2 N.m.

9
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
5
Insert and push the rear module until it locks into place.
IMPORTANT: Install the rear module in the orientation shown in the illustration.
If either unit is installed incorrectly, the connector may be damaged.
6
To remove the rear module, push the yellow button to unlock it, then pull the rear module out
following the illustration:

10
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
1.4. Electrical powering
•Supplying a power voltage other than that specified will damage the power source and the unit.
•When the FG terminal is connected, be sure the wire is grounded.

11
User manual SCAIME:
NU-eNodTouchM-E-0815_196774-B
1.5. RS485 interface for connection to eNod4
RS485 uses a DB9 connector. Please follow the below cable recommendation or use a SCAIME Cable ref 632153. Contact your
local sales representative for more information.
Important:
You may need to add a terminating resistor (120 Ohm) if
the distance between eNod4Touch and eNod4 is
important.
If distance is short (<1m), do not add resistor.

12
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
2. Off-Line setting
Offline mode provides access to system settings, self-diagnostics, and so on.
Use offline mode to set up the display unit before use.
2.1. Entering Offline mode
At Power ON
Touch the upper right corner or upper left corner (within 40 pixels of the edges) of the panel for at least 3 seconds soon after the
startup screen is displayed.
When Operating
Touch the upper right then bottom left corners, or the upper left and bottom right corners of the panel (within a 40 pixel area) in
0.5 seconds.
When the system menu is displayed, touch the [Offline] button

13
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
2.2. Offline mode operations
After entering in Offline mode, eNodTouch displays a menu allowing consulting and modifying the eNodTouch settings
2.2.1. Main unit Menu
Menu Input Parameter Description Default
Screen setting Initial screen Number Number of the screen that displays at startup 9
Standby mode setting Select the standby mode from [None], [Screen
OFF], or [Screen Change].
[None]
Standby Mode time set the time from 1 to 255 minutes after which
the screen is cleared
1
Change to Screen N° in
Standby Mode
Related to [Screen Change] Standby mode 1
Operation Settings Touch Panel Detection To detect touch on touching (ON) or Releasing
(OFF) the panel
ON
Touch Buzzer Sound Enable/Disable the in-built Buzzer sound upon a
touch
Disable
Display settings Show Brightness /
contrast control bar
Specify whether to display on touch the Control
Bar to adjust brightness and contrast.
Enable
D-Script_debug
Function
Enable
Menu and Error System Language English
Show System Menu Lower Part
Show Error Online [None]
Error Display Position Lower Part
Note: Never change the parameters in grey

14
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
2.2.2. Brightness/contrast control
•To display the Brightness Control Bar on the display unit, enable the setting [Show Brightness/Contrast Control Bar] in
[Display Settings] (§2.2.1)
•Touch the upper right then left corners, or the Bottom left and right corners of the display in 0.5 seconds.
•To end Brightness/Contrast Control mode, touch the [ X ] on the Brightness/Contrast Control Bar.
2.2.3. Peripheral – Device PLC Settings
Menu Input Parameter Description Default
Communication SIO Type Set the Communication type RS422/485 (2wire)
Speed Communication Speed : Should be set
according to eNod4 communication settings 19200
Data Length 8
Parity [None]
Stop Bit 2
Flow Control [None]
Time out (s) 1
Retry 1
Wait to send (ms) 10
Device Device Name eNod4_1 - eNod4_6
Slave Address
(Decimal)
eNod4 slave address : Should be set according
to eNod4 communication settings
1 - 6
Max. Query Read Input
Reg.
30
Max. Query Read
Holding Reg.
30
Max. Query Write
Holding Reg.
30
Note: Never change the parameters in grey
2.2.4. Password menu
Menu Input Parameter Description Default
System Password System Password The password setting is used when changing
to the Initialize Memory or offline mode
screens.
-
Security Password Security Password Not used -
Note: Never change the parameters in grey
2.2.5. Initialize menu
Menu Input Action
User memory Deletes all data in the display unit's internal memory.
Enter System password to operate, or 1101 (default password)
Backup Data Clears all the data stored in the display unit's backup memory.
Enter System password to operate, or 1101 (default password)
Note: Never use the commands in grey: You’ll lost the SCAIME eNodtouch application

15
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
2.2.6. Maintenance menu
Menu Input Action
Check Pattern Check the drawing function. Confirms whether the liquid crystal display (LCD) displays correctly
Check Touch Panel Touch panel check. Checks that the touched area lights up correctly.
Calibration Correct an analog touch panel. Continue touching until the crosshatch moves or disappears.
Check com Check the send and receive lines of network communication

16
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
3. On-Line Functioning
3.1. Startup screens
•At first Power-On, eNodTouch is set to manage one eNod4 at the address 1, the connection screen is displayed while
eNodTouch try to communicate with connected eNod4 device.
•Then a redirection screen appears during 3 seconds for a redirection to a main screen if the communication is
established between eNodTouch and eNod4 communication or an error screen if eNodTouch does not manage to
connect to the eNod.
•If there is no eNod4 connected or if the display unit cannot communicate with eNod4 device, a communication error
screen appears. In this case, check the wiring between eNodTouch and eNod4 (§1.4) and check that the communication
parameters of eNodTouch and eNod4 are correct (§2.2.3).
Connection screen Communication error screen
Redirection screen
•When communication is established the main screen of eNod4 appears :

17
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
3.2. Multi-eNod screens
3.2.1. Increase eNod number
•To increase the eNod number and have an access to the multi-eNod screen, please follow the procedure :
- Touch the Fn button of the main screen, the main menu appears.
- Enter in the eNodTouch menu.
- Go to the Starting Parameters screen by touching the right arrow button.
Main Menu
eNodTouch Menu Starting Parameters
•By default the eNod number is 1, eNodTouch starts on the main screen of the first eNod.
•Increase eNod number if needed. The display module can start on the main screen of any eNod or on the multi-eNod
screen by disabling « Starting eNod » function.
•If starting eNod is disconnected or have communication problems, the multi-eNod screen appears.
•When settings are finished, touch the left arrow button, to restart eNod Touch.
•According to the number of eNod settled, eNodTouch redirects to the following multi-eNod screens :

18
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
Multi-eNod (2 eNod) Multi-eNod (3 eNod)
Multi-eNod (4 eNod) Multi-eNod (5 eNod)
Multi-eNod (6 eNod)
Channel name Weight value
Unit
Gross
/
Net
Indicator
eNod4_1
eNod4_3
eNod4_5
eNod4_2
eNod4_4
eNod4_6

19
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
3.2.2. Select an eNod
•To display the main screen of an eNod, touch its display area (Example for eNod n°1):
Touch its display area Main screen of eNod
•To return to multi eNod screen, touch the channel red button:
Touch of channel button Multi-eNod screen

20
User manual SCAIME: NU-eNodTouchM-E-0815_196774-B
3.2.3. Communication error and disconnection
•When an eNod4 has communication problems or is disconnected, the data from other channels freezes for 5 seconds.
During this time, a reconnection button appears, eNodTouch tries to recover the connection with eNod4.
•After 5 seconds if eNodTouch can not recover the connection with eNod4, the button enters in the state « eNod
disconnected », the data display resumes.
•Identify the communication problem in the following list: wiring problem (§1.4), communication parameters
misconfigured on eNodTouch or eNod4 (§2.2.3).
•When you found out the issue, touch the « eNod disconnected » button to re-establish the communication.
•The display module tries to recover the communication with eNod4 during 1 second, the button toggles to the
« Reconnection » state. After 1 second if data from the eNod4 appears, the communication is re-established, else the
button toggles to « eNod disconnected » state.
Table of contents
Other Scaime Touch Panel manuals
Popular Touch Panel manuals by other brands

Cybernet
Cybernet iOne-MP17ix user manual

Avalue Technology
Avalue Technology AID-173SHR Quick reference guide

Computer Dynamics
Computer Dynamics MPAC-18 Operating and service manual

Boser
Boser BPC-5019 manual

ICOP Technology
ICOP Technology VOX-070-TS-EX2 Series user manual

AMX