Do not install this unit in any manner
except as described in these instructions.
Do not add any form of lubricant to cover adapter/
gasket assembly or risers during installation.
Make Sure Parts Are Clean When Applying Silicone or
Mastic Sealant
Doing so may result in property damage, personal injury or death.
DO NOT AIR TEST UNIT OR RISER SYSTEM!
SPECIAL PRECAUTIONS
For Schier riser Installations - Failure to follow this guidance voids your warranty
Installation Instructions
Installation instructions and additional components are included with
the base unit. Read all instructions prior to installation. This riser is
intended to be installed by a licensed plumber in conformance with all
local codes.
DO NOT
COMPACT
BACKFILL
concrete slab subject to hydrostatic pressure
watertight
concrete
vault
Hydrostatic/
Pressure Slabs
When installed under a
hydrostatic slab (slab
designed to withstand
upward lift, usually caused
by hydrostatic pressure)
interceptor must be
enclosed in a watertight
concrete vault.
max water table height
for direct burial
anchor kit
High Water
Table Installations
Interceptors and risers are not
designed to withstand water table
height in excess of the top of the
unit when buried (see figure). If it is
possible for this to occur, install
the interceptor and risers in a
water-tight concrete vault or
backfill with concrete or flowable
fill (wet concrete and flowable
backfill should be poured in
stages to avoid crushing the interceptor). At risk areas include but are
not limited to tidal surge areas, floodplains and areas that receive storm
water. Models that are direct buried in high water table scenarios must
be installed with an anchor kit. See base unit installation instructions for
selecting appropriate anchor kit.
Below Grade Installation Slab Requirements
A concrete slab to finished grade with rebar is required when
installing interceptor below grade.
Pedestrian Traffic or
Greenspace Areas Vehicular Traffic Areas
4" min. slab 8" min. slabRebarRebar
Installations with Risers
Max Water Level
Risers are not designed
to retain water
3 Risers (94") Max
Schier | FCR2 Installation Guide
page 2 of 10