Schmalz SCTMi User manual

Mini Compact Terminal SCTMi
Operating Instructions
WWW.SCHMALZ.COM EN-US · 30.30.01.02108 · 00 · 07/19

Note
The Operating instructions were originally written in German. Store in a safe place for future reference.
Subject to technical changes without notice. No responsibility is taken for printing or other types of er-
rors.
Published by
© J.SchmalzGmbH, 07/19
This document is protected by copyright. J.SchmalzGmbH retains the rights established thereby. Repro-
duction of the contents, in full or in part, is only permitted within the limits of the legal provisions of
copyright law. Any modifications to or abridgments of the document are prohibited without explicit writ-
ten agreement from J.SchmalzGmbH.
Contact
J. Schmalz GmbH
Johannes-Schmalz-Str. 1
72293 Glatten, Germany
T: +49 7443 2403-0
www.schmalz.com
Contact information for Schmalz companies and trade partners worldwide can be found at:
www.schmalz.com/salesnetwork
2 / 24 EN-US · 30.30.01.02108 · 00 · 07/19

Contents
EN-US · 30.30.01.02108 · 00 · 07/19 3 / 24
Contents
1 Important information ...................................................................................................................................5
1.1 Note on Using this Document ............................................................................................................... 5
1.2 The technical documentation is part of the product ........................................................................... 5
1.3 Warnings in This Document................................................................................................................... 5
1.4 Other applicable documents ................................................................................................................. 5
1.5 Symbol..................................................................................................................................................... 5
1.6 Type Plate ............................................................................................................................................... 6
2 Fundamental Safety Instructions...................................................................................................................7
2.1 Emissions ................................................................................................................................................. 7
2.2 Intended Use........................................................................................................................................... 7
2.3 Non-Intended Use .................................................................................................................................. 7
2.4 Personnel Qualification.......................................................................................................................... 8
2.5 Modifications to the Product................................................................................................................. 8
3 Product Description ........................................................................................................................................9
3.1 Mini compact terminal description ....................................................................................................... 9
3.2 Description of the Ejector ...................................................................................................................... 9
3.2.1 Depositing the Workpiece/Part (Blowing Off)........................................................................... 9
3.3 Variants and product keys ................................................................................................................... 10
3.4 Components of the Mini Compact Terminal ...................................................................................... 11
4 Technical Data ...............................................................................................................................................12
4.1 General parameters.............................................................................................................................. 12
4.2 Mechanical Data................................................................................................................................... 12
4.2.1 Performance Data...................................................................................................................... 12
4.2.2 SCTMi dimensions...................................................................................................................... 13
5 Transport and Storage..................................................................................................................................14
5.1 Checking the Delivery .......................................................................................................................... 14
5.2 Reusing the Packaging......................................................................................................................... 14
6 Installation.....................................................................................................................................................15
6.1 Installation Instructions........................................................................................................................ 15
6.2 Installation ............................................................................................................................................ 15
6.3 Pneumatic connection.......................................................................................................................... 16
6.4 Connecting the Compressed Air and Vacuum.................................................................................... 16
6.5 Optional: External blow-off connection (EB) ..................................................................................... 17
6.6 Electrical Connection............................................................................................................................ 17
6.6.1 Variant with plug connector M8 .............................................................................................. 18
7 Operation ......................................................................................................................................................19
7.1 General Preparations ........................................................................................................................... 19
7.2 Changing the Blow-Off Flow Rate on the Ejector.............................................................................. 19
8 Warranty........................................................................................................................................................20
9 Spare and wearing parts, accessories .........................................................................................................21
9.1 Spare and Wearing Parts ..................................................................................................................... 21
9.2 Accessories ............................................................................................................................................ 21

Contents
4 / 24 EN-US · 30.30.01.02108 · 00 · 07/19
10 Decommissioning and Recycling..................................................................................................................22
10.1 Disposing of the mini compact terminal............................................................................................. 22
10.2 Materials Used ...................................................................................................................................... 22
11 EC Declaration of Conformity ......................................................................................................................23

Important information
EN-US · 30.30.01.02108 · 00 · 07/19 5 / 24
1Important information
1.1Note on Using this Document
J.SchmalzGmbH is generally referred to as Schmalz in these Operating instructions.
These Operating instructions contain important notes and information about the different operating
phases of the product:
• Transport, storage, start of operations and decommissioning
• Safe operation, required maintenance, rectification of any faults
The Operating instructions describe the product at the time of delivery by Schmalz.
1.2The technical documentation is part of the product
1. For problem-free and safe operation, follow the instructions in the documents.
2. Keep the technical documentation in close proximity to the product. The documentation must be ac-
cessible to personnel at all times.
3. Pass on the technical documentation to subsequent users.
ðFailure to follow the instructions in these Operating instructions may result in life-threatening in-
juries!
ðSchmalz is not liable for damage or malfunctions that result from failure to heed these instructions.
If you still have questions after reading the technical documentation, contact Schmalz-service at:
www.schmalz.com/services
1.3Warnings in This Document
Warnings warn against hazards that may occur when handling the product. This document contains three
levels of danger that you can recognize by the signal word.
Signal word Meaning
WARNING Indicates a medium-risk hazard which, if not avoided, could result in death or
serious injury.
CAUTION Indicates a low-risk hazard which, if not avoided, could result in minor or
moderate injury.
NOTE Indicates a danger that leads to property damage.
1.4Other applicable documents
Important:
These instructions explain how to mount the mini compact terminal as well as the important points that
must be taken into account when using such a terminal.
For safe operation, the operating instructions 30.30.01.01961 for the mini compact ejector SCPMi must be
observed, in particular the explanation of operation and all functions of the SCPMi.
1.5Symbol
This sign indicates useful and important information.
üThis symbol represents a prerequisite that must be met prior to an operational step.
4This sign represents an action to be performed.
ðThis sign represents the result of an action.

Important information
6 / 24 EN-US · 30.30.01.02108 · 00 · 07/19
Actions that consist of more than one step are numbered:
1. First action to be performed.
2. Second action to be performed.
1.6Type Plate
1 2
The type plates (1) and (2) are permanently attached to the Terminal and must always be clearly legible.
The type plate (1) contains the following data:
• Designation, incl. individual configuration codes (terminal “XY”, ejector “AAA”)
The type plate (2) contains the following data:
• Part number
• Permitted pressure range
• Manufacturing date
• Serial number
• QR code
Identical individual discs are installed in groups in the terminal as blocks. The following counting method
is defined for identification of the ejector blocks:
The ejector block to the right of the type plate (1) is the first ejector block. The second ejector block is as-
sembled next to that one, and so on, up to a maximum of four blocks.
Please specify all the information above when ordering replacement parts, making warranty claims or for
any other inquiries.

Fundamental Safety Instructions
EN-US · 30.30.01.02108 · 00 · 07/19 7 / 24
2Fundamental Safety Instructions
2.1Emissions
The device emits noise due to operation with compressed air and a vacuum.
CAUTION
Noise pollution caused by exhaust air or leakage during operation
Hearing damage
4In the event of leakage, check connections and lines and remedy leakages
4Wear ear protectors.
2.2Intended Use
The terminal is built in accordance with the latest standards of technology and is delivered in a safe oper-
ating condition; however, hazards may arise during use.
The terminal is designed to generate a vacuum for gripping and transporting objects when used in con-
junction with suction cups. Depending on the design, the electrical control signals are transmitted directly
or via appropriate communication lines.
Neutral gases are approved as evacuation media. Neutral gases include air, nitrogen and inert gases (e.g.
argon, xenon and neon). For further information, see (> See ch. Technical Data).
The product is intended for industrial use.
Any other use is considered improper by the manufacturer and is deemed as contrary to the designated
use.
2.3Non-Intended Use
WARNING
Extraction of hazardous media, liquids or bulk material
Personal injury or damage to property!
4Do not extract harmful media such as dust, oil mists, vapors, aerosols etc.
4Do not extract aggressive gases or media such as acids, acid fumes, bases, biocides, dis-
infectants or detergents.
4Do not extract liquids or bulk materials, e.g. granulates.
Schmalz accepts no liability for damages caused by non-intended usage of the SCTM.
In particular, the following are considered non-intended use:
• Use in potentially explosive atmospheres
• Use in medical applications
• Lifting people or animals
• Evacuation of objects that are in danger of imploding

Fundamental Safety Instructions
8 / 24 EN-US · 30.30.01.02108 · 00 · 07/19
2.4Personnel Qualification
Unqualified personnel cannot recognize dangers and are therefore exposed to higher risks!
1. Only instruct qualified personnel to perform the tasks described in this manual.
2. The product may only be operated by persons who have undergone appropriate training.
3. Electrical work and installations may only be carried out by qualified electrical specialists.
4. Assembly and maintenance work may only be carried out by qualified personnel.
The following target groups are addressed in this manual:
• Installers who are trained in handling the product and can operate and install it
• Technically trained service personnel performing the maintenance work
• Technically trained persons who work on electrical equipment
2.5Modifications to the Product
Schmalz assumes no liability for consequences of modifications over which it has no control:
1. The product must be operated only in its original condition as delivered.
2. Use only original spare parts from Schmalz.
3. The product must be operated only in perfect condition.

Product Description
EN-US · 30.30.01.02108 · 00 · 07/19 9 / 24
3Product Description
3.1Mini compact terminal description
The Schmalz mini compact terminal SCTMi, or SCTMi for short, is a compact unit of multiple vacuum gen-
erators known as ejectors. Thanks to its modular design, up to 16 individual ejectors can be controlled and
configured independently. It can be used to handle different parts simultaneously and independently us-
ing just one vacuum system.
3.2Description of the Ejector
Every SCTMi mini compact ejector has an electrical connection to the voltage supply and to communica-
tion with the control for the superordinate machine.
The compressed air supply can be connected centrally for all ejectors. As an alternative, there can also be
a compressed air supply for each ejector.
3.2.1Depositing the Workpiece/Part (Blowing Off)
In blow-off mode, the vacuum circuit of the ejector is supplied with compressed air. This ensures that the
vacuum drops quickly, allowing the workpiece to be deposited quickly.
During blow-off, [-FF] is shown on the display.
The ejector provides three blow-off modes for selection:
• Externally controlled blow-off
• Internally time-controlled blow-off
• Externally time-controlled blow-off

Product Description
10 / 24 EN-US · 30.30.01.02108 · 00 · 07/19
• Optional: External blow-off (EB function)
3.3Variants and product keys
The item designation of the SCTM is composed of a product key, which indicates the number of ejectors
installed and their exact properties.
The SCTM product key (so-called system configuration), e.g. SCTMc-MP-6-XY-2AAF-2AB0-2AAH, is com-
posed as follows:
Feature Variants Comment
Product class SCTM terminal with c-ejectors
Basic: b
Controlled: c
Intelligent: i
—
Terminal type MP (multipole), [IOL, ECT , EIP , PNT] MP is only available in the SCTMc vari-
ant
Number of ejec-
tors
6 Max. of 16; for SCTMc MP the max. is
only 7
Code terminal XY Contains all basic functions/properties
in coded form
Ejector block 1 2 AAF individual discs Contains the complete “type informa-
tion” of the blocked individual discs
Ejector block 2 2 AB0 individual discs
Ejector block 3 2 AAH individual discs
Important notes:
• Only unmixed terminals may be constructed (b, c, or i ejectors)
• A maximum of 4 individual discs can be used
• Identical individual discs must be installed grouped together as blocks.
• The combination of the optional functions “External blow-off (EB)” and “External vacuum (EV)”
cannot be selected.

Product Description
EN-US · 30.30.01.02108 · 00 · 07/19 11 / 24
3.4Components of the Mini Compact Terminal
5
4
9
8
1
13 12
710
6
3
2
11
14
1 4x mounting slots 2 2x end plates
3 Type plate 1 4 Mini compact ejector SCTMti
5 M8 electrical connection, 6-pole 6 Operating and display elements
7 Optional: Compressed air connection in-
terface for each ejector disc
8 Compressed air connection (feed through
both end plates for 9 or more individual
discs.)
9 Vacuum connection 10 Optional: Compressed air connector for
external blow-off EB (marking 1A)
11 Type plate 2 12 Optional: Collective exhaust air connector
(marking 3)
13 Blow-off valve screw 14 Silencer (marking 3)

Technical Data
12 / 24 EN-US · 30.30.01.02108 · 00 · 07/19
4Technical Data
4.1General parameters
Parameter Type Symbol Limit value Unit Note
min. typ. max.
Working tempera-
ture
Tamb 0 — 50 °C —
Storage tempera-
ture
TSto -10 — 60 °C —
Humidity Hrel 10 — 85 % r.h. Free from condensa-
tion
Degree of protec-
tion
— — — IP40 — —
Operating pres-
sure (flow pres-
sure)
03 P 2 4 6 bar —
05, 07
and 10
P 3 4 6 bar —
Operating
medium
Air or neutral gas, filtered to 5µm, without oil, class 3-3-3 compressed air quality
in acc. with ISO8573-1
4.2Mechanical Data
4.2.1Performance Data
Type Nozzle
03
Nozzle
05
Nozzle
07
Nozzle
10
Nozzle size [mm] 0.3 0.5 0.7 1.0
Degree of evacuation [%] 87
Max. suction rate [l/min] 1) 2.2 7.5 15 28
Air consumption for suction [l/min] 2) 3.5 9 22 45
Air consumption for blow off [l/min] 2) 10
Sound pressure level, unobstructed [dB(A)] 1)2) 51 66 70 71
Sound pressure level, suction [dB(A)] 2) 42 55 70 72
Pressure range [bar] 2 to 6 3 to 6
Rec. diameter of compressed air hose [mm] 3) 6
Rec. diameter of vacuum hose [mm] 3) 2 4
1) At optimal operating pressure (SCPM...03/05/07: 4 bar; SCPM...10: 4.5bar)
2) The values specified apply to each ejector. The values for terminals vary according to the number of
ejectors installed.
3) For max. length of 2m

Technical Data
EN-US · 30.30.01.02108 · 00 · 07/19 13 / 24
4.2.2SCTMi dimensions
B B1 B2 B4 d G1(d1) G2(d2) H H1
79.9 96.1 9.2 42.9 4.5 6 8 65.8 74.4
H2 H3 H4 L L1 L2 L3 X1 Y1
31.5 8 8 37.8+(n*12.5) 56.8+(n*12.5) 15 12.5 45.8+(n*12.5) 32.5
All dimensions given in millimeters [mm].
The letter “n” stands for the number of ejector discs installed in the terminal.
The weight of one terminal amounts to:
• approx. 175g+(n*80)g if it has up to and including 9 ejectors
• approx. 205g+(n*80)g if it has 10 to 16 ejectors

Transport and Storage
14 / 24 EN-US · 30.30.01.02108 · 00 · 07/19
5Transport and Storage
5.1Checking the Delivery
The scope of delivery can be found in the order confirmation. The weights and dimensions are listed in
the delivery notes.
1. Compare the entire delivery with the supplied delivery notes to make sure nothing is missing.
2. Damage caused by defective packaging or occurring in transit must be reported immediately to the
carrier and J.SchmalzGmbH.
5.2Reusing the Packaging
The product is delivered in cardboard packaging. The packaging should be reused to safely transport the
product at a later stage.
Keep the packaging for future transport or storage.

Installation
EN-US · 30.30.01.02108 · 00 · 07/19 15 / 24
6Installation
6.1Installation Instructions
CAUTION
Improper installation or maintenance
Personal injury or damage to property
4Prior to installation and before maintenance work, the compact terminal must be dis-
connected from the power supply and secured against unauthorized restart!
For safe installation, the following instructions must be observed:
1. Use only the connections, mounting holes and attachment materials that have been provided.
2. Firmly connect and secure pneumatic and electrical line connections to the compact terminal.
3. Ensure that there is adequate installation space in the area where the product will be installed.
6.2Installation
The mini compact terminal may be installed in any position.
The mini compact terminal is attached using the mounting slots (4 pieces). There is also the option of
mounting DIN rails.
4The four slots are used to attach them. The
mini compact terminal must be secured in
place using at least 4 M4 screws. The maxi-
mum tightening torque is 2Nm.
4As an option, the holes can be used to attach
DIN rails for mounting.

Installation
16 / 24 EN-US · 30.30.01.02108 · 00 · 07/19
6.3Pneumatic connection
CAUTION
Compressed air or vacuum in direct contact with the eye
Severe eye injury
4Wear eye protection
4Do not look into compressed air openings
4Do not look into the silencer air stream
4Do not look into vacuum openings, e.g. suction cups
CAUTION
Noise pollution due to incorrect installation of the pressure and vacuum connec-
tions
Hearing damage
4Correct installation.
4Wear ear protectors.
6.4Connecting the Compressed Air and Vacuum
1 1
2
3
1 1x compressed air connection per 9 ejec-
tor discs (marking 1)
2 1x vacuum air connection per ejector disc
(marking 2)
3 Optional: 1x compressed air connection
per ejector disc (marking 1)
The compressed air connector with the plug connector 8/6 or 1/8” thread is marked with the number 1 on
the ejector disc.
4Connect compressed air hose. For threaded connectors, the maximum tightening torque is 1Nm.
The vacuum connector with the plug connector 8/2 or 6/4 or M5 or M7 thread is marked with the number
2 on the ejector disc.
4Connect the vacuum hose. For threaded connectors, the maximum tightening torque is 1Nm.

Installation
EN-US · 30.30.01.02108 · 00 · 07/19 17 / 24
6.5Optional: External blow-off connection (EB)
The terminal is also available with an additional compressed air connector for the blow-off function.
With the external blow-off function (EB), the blow-off pulse is controlled separately and independently of
the compressed air supply for vacuum generation, allowing you to use a different medium (e.g. nitrogen)
for the blow-off function.
It also allows you to precisely set the blow-off pressure using an external pressure regulator (between 2
and 6 bar).
The blow-off flow rate can also be set between 0% and 100% directly on the respective ejector disc. This
can be used, for example, to set down small and lightweight workpieces with high positioning precision.
The hose size and the thread on the connector depend on the particular ejector disc and can have the fol-
lowing dimensions:
• Push-in: 8/6
• Thread: 1/8" thread, female
4Connect the compressed air hose for external
blow-off (connector marked with 1A) and ad-
just the blow-off flow rate using the adjusting
screw (2).
1A
2
6.6Electrical Connection
NOTE
Change of output signals when product is switched on or plug is connected
Personal injury or damage to property
4Electrical connection may be performed only by specialists who can evaluate the effects
of signal changes on the overall system.
NOTE
Incorrect power supply
Destruction of the integrated electronics
4Operate the product using a power supply unit with protected extra-low voltage
(PELV).
4The system must incorporate safe electrical cut-off of the power supply in compliance
with EN60204.
4Do not connect or disconnect the connector under tension and/or when voltage is ap-
plied.

Installation
18 / 24 EN-US · 30.30.01.02108 · 00 · 07/19
6.6.1Variant with plug connector M8
The electrical connection supplies the ejector with power and communicates with the control system of
the higher-level machine using defined outputs.
üProvide a connection cable with an M8 plug (customer’s responsibility).
4Attach the connection cable to the electrical
connection point (1) on each ejector, max.
tightening torque = hand-tight.
1
Ensure that the electrical cable does not exceed the maximum length of 20 meters.
Pin assignments
M8 plug PIN Symbol Wire color 1) Function
1 US Brown 24V power supply
2 IN1 White “Suction” signal input
3 GND Blue Ground
4 OUT / CQ Black “Parts control” output (SP2) or IO-
Link
5 IN2 Gray “Blow-off” signal input
6 — Pink Not used
1) When using a Schmalz connection cable, part no. 21.04.05.00488 (see accessories)

Operation
EN-US · 30.30.01.02108 · 00 · 07/19 19 / 24
7Operation
7.1General Preparations
WARNING
Extraction of hazardous media, liquids or bulk material
Personal injury or damage to property!
4Do not extract harmful media such as dust, oil mists, vapors, aerosols etc.
4Do not extract aggressive gases or media such as acids, acid fumes, bases, biocides, dis-
infectants or detergents.
4Do not extract liquids or bulk materials, e.g. granulates.
Always carry out the following tasks before activating the system:
1. Before each start of operations, ensure that the safety features are in perfect condition and fully
functional.
2. Check the device for visible damage and deal with any problems immediately (or notify the supervi-
sor).
3. Ensure that only authorized persons are present in the working area of the machine or system in or-
der to prevent any hazard from switching on the machine.
7.2Changing the Blow-Off Flow Rate on the Ejector
Do not overwind the stop on the valve screw. A minimum flow rate of approx. 15% is always
necessary for technical reasons. The blow-off volume flow can be set between 15% and
100%.
There is a valve screw below the vacuum connection that can be used to adjust the blow-off flow rate.
The valve screw is equipped with a stop on both sides.
Valve screw
+
-
1. Turn the valve screw clockwise to reduce the flow rate.
2. Turn the valve screw counterclockwise to increase the flow rate.

Warranty
20 / 24 EN-US · 30.30.01.02108 · 00 · 07/19
8Warranty
This system is guaranteed in accordance with our general terms of trade and delivery. The same applies to
spare parts, provided that these are original parts supplied by us.
We are not liable for any damage resulting from the use of non-original spare parts or accessories.
The exclusive use of original spare parts is a prerequisite for the proper functioning of the system and for
the validity of the warranty.
Wearing parts are not covered by the warranty.
Table of contents
Other Schmalz Touch Terminal manuals