2
Operating instructions
Safety sensor RSS36 AS
EN
1.6 Warning about misuse
In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant
components cannot be excluded when safety switchgear is
used. The relevant requirements of the standard ISO 14119
must be observed.
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with this operating instructions
manual. The manufacturer shall accept no liability for damages result-
ing from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary re-
pairs, conversions and modifications to the device are strictly forbidden;
the manufacturer shall accept no liability for damages resulting from
such invasive work, arbitrary repairs, conversions and/or modifications
to the device.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
RSS36-
➀
-ST-AS-
➁
No. Option Description
➀
Standard coding
AD
Standard coding, actuator detection
I1
Individual coding
I2
Individual coding, re-teaching enabled
➁without latching
R
with latching, latching force approx. 18 N
Actuator
RST36-1 without latching
RST36-1-R with latching, latching force approx. 18 N
RST36-1-AD01…15 without latching, with actuator detection
2.2 Special versions
For special versions, which are not listed in the order code below 2.1,
these specifications apply accordingly, provided that they correspond to
the standard version.
2.3 Comprehensive quality insurance to 2006/42/EC
Schmersal is a certified company to appendix X of the Machinery Direc-
tive. As a result, Schmersal is entitled to autonomously conduct the
conformity assessment procedure for the products listed in Appendix
IV of the MD without involving a notified body. The EC prototype test
certificates are available upon request or can be downloaded from the
Internet at www.schmersal.com.
2.4 Destination and use
This non-contact, electronic safety sensor is designed for application in
safety circuits and is used for monitoring the position of movable safety
guards. In this application, the safety sensor monitors the position of
hinged, sliding or removable safety guards by means of the coded
electronic actuator.
The safety function consists of safely switching off the code trans-
mission when the safety guard is opened and maintaining the safe
switched off condition for as long as the safety guard is open.
The safety switchgears are classied according to
ISO 14119 as type 4 switching devices.
Designs with individual coding are classied as highly
coded and are labelled with "High Level Code".
An AS-Interface Safety at Work component functions on the basis of an
individual code generator (8 x 4 bit). This safety code is cyclically trans-
mitted over the AS-i network and monitored by a safety monitor.
Safety sensors and actuators with latching (ordering suffix 'R') must
always be used in pairs. The latching force (approx. 18 N) exercised by
the permanent magnet keeps hatches and small guards closed, also in
a de-energised condition.
The system can be used as a door end stop up to 5 kg at 0.25 m/s.
The user must evaluate and design the safety chain in
accordance with the relevant standards and the required
safety level.
2.5 Technical data
Standards: IEC 60947-5-3, EN 50295
Working principle: RFID
Coding level according to ISO 14119:
- I1-version: high
- I2-version: high
- Standard coding version: low
Material of the housings: Plastic, glass-fibre reinforced thermoplastic,
self-extinguishing
Response time: < 100 ms
Duration of risk: < 200 ms
Time to readiness: ≤ 5 s
Switching frequency f: ≤ 1 Hz
Actuator: RST36-1, RST36-1-R, RST36-1-AD01…15
Mechanical data
Execution of the electrical connection: M12 connector plug, 4 poles
Mechanical life: ≥ 1 million operations
- when used as door stop: for safety guards ≤ 5 kg and
actuating speed ≤ 0.25 m/s
Switching distance sn:12 mm
- Assured switch-on distance sao:10 mm
- Assured switch-off distance sar: 16 mm
- Hysteresis: < 2.0 mm
- Repeat accuracy R: < 0.5 mm
Latching force (R): approx. 18 N
Ambient conditions
Ambient temperature: −25 °C ... +70 °C
Storage and transport temperature: −25 °C ... +85 °C
Resistance to shock: 30 g / 11 ms
Resistance to vibration: 10 … 55 Hz, amplitude 1 mm
Protection class: IP65 / IP67 to IEC/EN 60529
IP69K to DIN 40050-9
Protection class: II
Insulation values to IEC/EN 60664-1:
- Rated impulse withstand voltage Uimp:0.8 kV
- Rated insulation voltage Ui:32 VDC
- Overvoltage category: III
- Degree of pollution: 3
Electrical data - AS-Interface
AS-i supply voltage: 18.0 ... 31.6 VDC,
protection against polarity reversal
AS-i power consumption: ≤ 100 mA
AS-i device insulation: internal short-circuit proof
AS-i specification:
- Version: V 3.0
- Profile: S-0.B.F.E
AS-i inputs:
- Channel 1: Data bits DI 0/DI 1 = dynamic code transmission
- Channel 2: Data bits DI 2/DI 3 = dynamic code transmission
Databits condition static 0 or
dynamic code transmission
AS-i Outputs:
- DO 0 ... DO 3: no Function