Important Safeguards:
• Pleasereadallinstructions.
• Donottouchhotsurfaces.Donotpickup
wheninuse.
• Toprotectagainstelectricalshock,donot
immersecord,plugsorunitinwaterorother
liquid.
• Unplugunitwhennotinuseandbeforeclean-
ing.Allowunittocoolbeforeproceeding.
• Donotoperateunitwithadamagedcordor
plug,oriftheappliancemalfunctionsorhas
beendamagedinanymanner.ReturntoSci-
enceFirst®forexamination,repairoradjust-
ment.
• Donotuseoutdoors.
• Donotletcordhangoveredgeoftableor
counterortouchhotsurfaces.
• Donotplaceonornearahotgasorelectric
burner,orinaheatedover.
• Donotmoveappliancewhenlledwithhot
liquids.
• Donotuseapplianceforotherthanintended
use.
• Todisconnect,switchtheunit"OFF",then
removeplugfromwalloutlet.
Updated features:
•Digitallycontrolledtemperaturesetting
•TemperaturereadsinFarenheitandCelsius
•Temperaturerange:77°Fto176°F
(25°C-80°C)
•Digitallycontrolledtimerwithautomatic
shut-off
•StyreneLiner
•Spatula
Maintenance:
• Thefuseisaccessibleviathebackpanelfuseholder.
**Unplugthewaterbathbeforeremovingthefuse.To
removethefuse,opentheblackfuseholder,located
justabovetheplugoutletandpullouttoremovethe
fuse.Replacefuseifnecessary.
• Thewaterreceptacleisnotremovable.Cleanoften
withanysuitablestainlesssteelcleaner.(Werecom-
mendScience First® 29-0701 Stai-Clean15oz.
aerosolspraystainlesssteelcleaner.)
Caution: Do
not immerse
in water
Corrosionshouldnot beaproblemsincetheunitis
constructedof18-8nickel-bearingstainlesssteel.The
waterreceptacleissealedbelowtherimsothataccidental
spillageispreventedfrompenetratingtotheinside.
How To Use:
1.)Fillreservoir toalevelwhichwillallowthewater
torisewithoutoverowingwhenthelargestobjectisim-
mersed.**Important: To avoid damage, always keep
water level at least half full.
2.)Connectto110-120v 60 Hz outlet.
3.)TurnunitonbypushingRockerSwitchlocated
belowredLEDlamp.TheRockerSwitchwillstayil-
luminatedaslongasitisinthedownposition.
4.)Tosetthedesiredtemperature,pressthe"Set"but-
ton.Theentiredisplaywillbegintoash.Pressthe"up"
and"down"keysuntilthedesiredtemperatureisreached.
Pressthe"Set"buttonagaintolockinthenewtempera-
ture.Thedisplaywillnowshowthesettemperaturein
theupperrightcorner.Itwillread"Set:(temperature)".
5.)Whenthethermbathisheating,thedisplaywill
read"heating"andshowthecurrenttemperatureinthe
mainpartofthedisplay.TheredLEDlampabovethe
rockerswitchwillilluminatewhentheunitisheating,
andgodarkwhentheunitisholdingtemperature.
Description:
Thenewandimprovedthermbathisnowadigital-
ly controlledwarm-waterbath.Useforanyprocedure
wheremedium heat isrequired.
Thethermbathiscapableofheatingfrom77°Fto
176°F.TheunitcanbeconvertedtodegreesCelsius
(25°C-80°C)bythetouchofthe"F/C"buttton.