29
3. TIMER SETTING :
Press “MODE” once and the “SET TIME” indicator lamp will
illuminate. The display will show “060” indicating 60 minutes.
time may be adjusted via the up and down arrow keys.
from 0 to 60 minutes. If set on the “000” position, the unit will
run continuously.
NOTE: when operating at time setting ”000” the unit must not be
allowed to run continuously for longer than 8 hours.
4. TEMPERATURE SETTING :
Press “MODE” twice and the “SET TEMP” indicator lamp will
illuminate. The display will initially show current water
temperature. Temperature may be adjusted via the up and down
arrow keys.
Temperature is adjustable from 0 to 80°C displayed as 000 - 080
NOTE: This is a heated unit only, so will only heat from ambient
water temperature +7°C and higher. If the temperature is set
lower than the water temperature in the unit, it will not heat.
The unit will not reset itself and the set temperature will remain
unless changed by the operator.
5. POWER SETTING :
Press “MODE” Three times and the “SET POWER” indicator lamp
will illuminate. There are 5 power levels 001 -005. The display will
initially show “005” . This setting reduces or increases the size of
the cavitation bubble implosion force which effects the aggression
of the cleaning action, where 005 is the strongest.
Power may be adjusted via the up and down arrow keys.
6. FREQUENCY SETTING :
Press “MODE” Four times and the “SET FREQ” indicator lamp
will illuminate. There are two options LO and HI. The display will
initially show “LO” . This setting effects the size and spread of the
cavitation bubbles. This inuences the erosion and cleaning
action on surfaces. The “HI” setting provides the most even and
minimal erosion of surfaces and is suitable for cleaning smaller
particles. The “LO” setting cleaning and erosion is more
aggressive. Frequency may be adjusted via the up and down
arrow keys.
ON
OFF
POWER
START
STOP
SONICS
MODE
SET
FUNCTION
SET TIME
SET FREQ
SET POWER
SET TEMP
R1
PCB1
PCB2
TD
PROBE
E1
WIRING DIAGRAM
MODEL: ULTRASONIC CLEANER
MODEL CODE: 702, 703, 704, 705
LEGEND DESCRIPTION
S1 ROCKER SWITCH
TD TRANSDUCER
PCB1 PC RELAY BOARD
E1 ELEMENT
PROBE TEMPERATURE PROBE
FP FASCIA CONTROL PANEL
PCB2 PC CONTROL BOARD
S1
FP