5 Programming The Receiver To Button Transmitters
With any of the above (RF KEY/RFWB-40G/RFWB-20G/
RFIM-40B) use the table in section 4 to program the
switching socket to function as indicated. Push the button
or switch (slowly and positively) the amount of times shown
to program the corresponding function. E.g. Function 4 will
require 4 presses.
Up to 32 transmitting devices can be paired with the
If you are using the “RF Pilot” or the
“RF Touch” (left) you can enter the
address of the switching socket. The
address of the unit can be found here.
Once you have pressed the button/
switch on the transmitter the
correct amount of times, press the
‘STATUS/PROG’ button <1 second
to complete.
Once the unit has been programmed
you can plug in your desired
appliance.
7a 7b
6a
If an error has been made during programming, a single
pairing can easily be removed.
1. Press and hold the “STATUS/PROG” button for 5
seconds. The red indicator will ash twice a second.
2. Press the transmitter button paired incorrectly. The red
indicator should stop ashing conrming the pairing is
removed.
To remove all pairings press and hold the “STATUS/
PROG” button for 10 seconds, release, then press <1
second to complete.
With RFIM-40B
When installing with the RF Pilot or RF Touch, use the dedicated product manuals for programming
Switching Socket.
If an error during programming has been made see step 6.
Functions 5 and 6 time delay options: After the initial 5 or
6 presses, hold the ‘STATUS/PROG’ button for a further 5
seconds. The red indicator will ash 2 times a second, the
timer has started. After the required time has run press the
button on the transmitter originally paired above to stop the
timer.
Then proceed to step 7.
6 Removing Pairings
6b
7 Exiting Programming
8 Programming - RF Pilot & RF Touch
Scolmore Park, Landsberg, Licheld Road Industrial Estate, Tamworth, Staffordshire B79 7XB
Tel: +44 (0) 1827 63454 Fax: +44 (0) 1827 63362 www.scolmore.com V2.0
CS2 - Memory Status
Single LED ash on exit - Memory status not engaged
Double LED ash on exit - Memory status is engaged
To toggle between status’s enter and exit programming mode.