Sealey SCMA1 User manual

CARBON MONOXIDE ALARM
MODEL NO: SCMA1
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
1.1. WHAT IS CARBON MONOXIDE?
1.1.1. Carbon Monoxide (CO) is an insidious poison that is released when fuels are burnt. It is a colourless, odourless, tasteless gas and
thereforeverydiculttodetectwiththehumansenses.COkillshundredsofpeopleeachyearandinjuresmanymore.Itbinds
tohaemoglobininthebloodandreducestheamountofoxygenbeingcirculatedinthebody.InhighconcentrationsCOcan
killinminutes.COisproducedbytheincompletecombustionoffuelssuchaswood,charcoal,coal,heatingoil,paran,
petrol, natural gas, propane, butane etc.
1.1.2. ExamplesofCOsources:
Runningcarengineinagarage,oilandgasfurnaces,woodstoves,barbecues,cloggedchimneys,woodandgasreplaces,heating
boiler,gasappliances,portablegenerators,gasorkeroseneheaters.
1.2. SYMPTOMS OF CO POISONING
ThefollowingsymptomsmayberelatedtoCOpoisoning:
35ppm Themaximumallowableconcentrationforcontinuousexposureforhealthyadultsinany8hourperiod.
200ppm Slightheadaches,fatigue,dizziness,nauseaafter2-3hours.
400ppm Frontalheadacheswithin1-2hours,lifethreateningafter3hours.
800ppm Dizziness,nauseaandconvulsionswithin45minutes,unconsciousnesswithin2hours,deathwithin3hours.
1600ppmHeadache,dizzinessandnauseawithin20minutes,deathwithin1hour.
6400ppmHeadache,dizzinessandnauseawithin1-2minutes.
1.3. InstallingaCOalarmisonlytherststeptowardssaferlivingconditions.Makesurethatyouandtheothermembersofyour
householdarefamiliarwiththecauseandeectsofcarbonmonoxidepoisoningandhowtooperatetheCOalarm.
9 TestyourCOalarmonceamonth.
9 Replacelowbatteriesimmediately.
9 Onlypurchaseapprovedcombustiondevices.
9 Installcombustiondevicesinthecorrectwayandstrictlyfollowtheinstructionsofthemanufacturer.
9 Haveanyinstallationscarriedoutbyaprofessional.
9 Haveyourinstallationscheckedbyaqualifiedinstalleronaregularbasis.
9 Haveyourchimneyandanydrainagecleanedeveryyear.
9 Regularlycheckallcombustiondevicesandverifyifdevicesarefreeofcorrosion.
9Never use a barbecue indoors or in garages.
9 Ensureproperventilationwhenusingafireplaceormultiburner.
9 AlwayspayattentiontothesymptomsofCarbonMonoxidepoisoning.
9 Thisalarmcanonlybeusedforresidentialapplications,itisNOTsuitableforuseonboats,invehicles,factoriesorshoppingmallsetc.
8 Avoidcontactwithorganicsolvents(includingsiliconeandotheradhesives),coatings,pharmaceutical,oilandhighconcentrationsof
gas.Thisunitcannotbeusedinenvironmentscontainingcorrosivegas,corrosivegascandamagetheunit.
8DO NOTusewherethereisstrongwindmovement.
8DO NOTblockthealarmsairinletotherwisetheunit’ssensitivitywillbeaffected.
8 Thisunitcannotbearexcessiveshockorvibration.
8 Itwilltakethisalarmalongtimetoreturntoitsinitialstateafterithasbeenusedinhighconcentrationsofgasforalongtime.
8 Neveropentheunit,electrolyteleakagecancausedamage.
8 ThisCOalarmisdesignedonlytosenseCarbonMonoxidefromanysourceofcombustion.Itis NOT designedtodetectsmoke,fire
and other gases.
WARNING: Thisdeviceisdesignedtoprotectindividualsfromacuteeffectsofcarbonmonoxideexposure.Itmaynotfullysafeguard
individualswithspecificmedicalconditions.Ifindoubt,consultamedicalpractitioner.
2. INTRODUCTION
CertiedtoBSEN50291-1:2010+A1:2012.Memoryfeatureallowstheoperatortodetectifandwhenthealarmhassoundedwhiletherehas
beenno-onepresent.FrontLEDpanelindicateslowbatteryandfault.PoweredbythreeAAbatteries(notincluded).Maximumlifespanve
years.
3. SPECIFICATION
MODEL NO:............................................................. SCMA1
Batteries (not included) .................................................3x AA
SCMA1 Issue 2 23/06/2020
Original Language Version
©JackSealeyLimited
Refer to
instructions

4. LOCATING THE ALARM
ThisalarmisdesignedtodetecttoxicCOfumesthatresultfromincompletecombustion,suchasthoseemittedfromappliances,
furnaces,replacesandcarexhausts.
4.1. Ifyourdwellingisonasinglestorey,forminimumprotectionyoushouldtanalarminthebedroomsorinthehallwayofthe
sleepingareas.Placeitasneartothesleepingareasaspossibleandensurethealarmisaudiblewhenthebedrooms
are occupied.
4.2. Ifyourdwellingismultistorey,forminimumprotectionplaceatleastonealarmoneachoor.
NOTE: Formaximumprotectionanalarmshouldbettedinorneareveryroomthatcontainsafuelburningappliancesuchasanygasres,
centralheatingboilers,roomheaters,waterheaters,cookers,grillsetc.
WARNING!Thisalarmwillonlyindicatethepresenceofcarbonmonoxidegasatthesensor.CarbonMonoxidemaybepresentin
other areas.
WARNING! A Carbon Monoxide alarm does not function as a replacement for a smoke or gas detector.
5. POSITIONING THE ALARM
5.1. CarbonMonoxidehasasimilardensitytowarmairandtoensurethatthemosteectiveuseismadeofthedetector,itshouldbe
ttedatleast1.5metres(5feet)aboveoorlevelandatleast1.85metres(6feet)fromtheappliance.Seeg.1.
5.2. Areas to be avoided include the following:
•situationswherethetemperaturemayfallbelow-10°Corriseabove40°C.
•inadamporhumidarea.
•anyareawherehighlevelsofdusty,dirtyorgreasyemissionscouldcontaminateorclogthesensor.
• behind curtains or furniture.
•inthepathofairdischargedfromafurnace,airconditioningventorceilingfan.
• outside the building.
•directlyaboveasinkorcooker.
WARNING: Thiscarbonmonoxidealarmisdesignedforindooruseonly.DO NOTexposetorainormoisture.Itwillnotprotect
againsttheriskofcarbonmonoxidepoisoningwhenthebatteryhasdrained. DO NOTopenuportamperwiththealarmasthis
couldcauseamalfunction.
6. INSTALLATION
6.1. Thiscarbonmonoxidealarmispoweredbybatteryandrequiresnoadditionalwiring.Itcaneitherbeinstalledonawall,usingthe
xingsprovided,oronatabletop.
6.2. WALL MOUNTED INSTALLATION
6.2.1. Establishthemountinglocationseesection5.1.andensurethereisnoelectricalwiringorpipeworkintheareaadjacenttothe
mountingsurface.
6.2.2. Markthetwomountingholelocationsanddrillholes.
6.2.3. Screwthescrewsintothedrilledholesandkeepthescrewsoutby4mm.Hangunitonwall.
6.3. TABLE TOP INSTALLATION
6.3.1. PlacealarmonatabletopsothatuserscanseetheLEDsclearly.
7. OPERATION
7.1. INSTALL BATTERIES (REFER TO FIG.2)
7.1.1. Thealarmispoweredby3xLR6sizeAA1.5Vbatteries.
7.1.2. Undothescrewandreleasethecliptoopenthebatterycompartmentdoorontherearofthedetector.
7.1.3. Makesurethebatteriesareinsertedthecorrectwayround(seethepolaritydiagramsinthebottomofthecompartment).
7.1.4. Theredplasticindicatorhastotunderthebattery,thedoorwillnotshutifthisisnotdone.
g.1
SCMA1 Issue 2 23/06/2020
Original Language Version
©JackSealeyLimited

7.2. NORMAL OPERATION
7.2.1. WhennoCarbonMonoxideispresent,thegreenLEDashesonceevery50seconds,theLCDdisplays“0PPM”andthespeaker
symbolisindicatedtoshowyouralarmisinnormalworkingcondition.Seeg.3.
7.3. HOW TO TEST THE CO ALARM
7.3.1. PresstheTESTbutton,theunitwilltriggerananalogueoutputofhighCOconcentrationthatwillbedetectedbytheMCU,thusstarting
alarmingtogetherwiththeredLEDashing,simultaneouslytheunitwilldisplaythesimulatedCOconcentrationwiththe“SPEAKER”
symbolashing,(SPEAKERsymbol)seeg.4.
NOTE: Testthisalarmwhenthe“ppm”symbolisdisplayedintheLCDafterthebatterieshavebeeninstalled.Thoughthisalarmcan
self-diagnosetheamplifyingcircuitandsensor,itisrecommendedthatyoutestyourCOalarmonceamonthtoensureitisworking
correctly.
7.4. ALARM LOCKING
7.4.1. IftheTESTbuttonispressedagainwhilsttheCOalarmissounding,
thealarmwillmoveintoLOCKINGstatusandtheredLEDandthe
greenLEDwillashevery10secondsatthesametime,the
“SPEAKER”symbolontheLCDwilldisappear.Theunitwillnot
respondtoanyactionduringthe2minuteLOCKINGstatus.IftheCO
concentrationexceeds300PPMin3minutes,theunitwillstart
alarming,seeg.5.
7.4.2. WhentheCOconcentrationgoesdowntoorbelow5PPMtheunitwill
stopalarming.
g.2
g.3 g.4
g.5
SCMA1 Issue 2 23/06/2020
Original Language Version
©JackSealeyLimited

7.5. LOCKING RELEASE
7.5.1. PresstheTESTbutton,theunitwillreturntoNormalOperationstatus,seeg.3.
7.6. ALARM CONDITION
7.6.1. WhentheunitdetectsdangerouslevelsofCO,itwillemitanalarmsignalalongwithashingredLED,seeg.4.Thiswillcontinue
aslongasthereisadangerouslevelofCOconcentrationoforequalto5PPM.TheLCDwillshowtheconcentrationandSPEAKER
symbol.Thiswillindicatethatanalarmhasoccurredanditshouldbeinvestigated.
NOTE: Tostopthealarmreferto7.4.
7.7. MEMORY FUNCTION
7.7.1. Whennooneishome,theunitmaydetectCOandthealarmsound.ThealarmstopswhentheCOconditionreturnstonormal.The
highestCOconcentrationthatwaspresent,willberecordedandshownontheLCDwiththe“COgure”ickeringonceevery15
seconds,togetherwith2continuous“beep”,“beep”sounds,redLEDandthe“SPEAKER”symbolashing,seeg.6.
7.7.2. PresstheTESTbutton,the“COgure”willthenbeclearedandtheunitreturnstonormalworkingcondition,seeg.3.
7.8. LOW BATTERY SIGNAL
7.8.1. Whentheunitdetectsthebatteryvoltageislowandneedsreplacing,theredLEDwillbeepevery40secondsalongwithoneBEEP.
TheLCDwillshowtheLOWVOLTAGEsymbol,seeg.6.
7.8.2. TheredLEDwillashasusual,duringthelowbatteryperiod,andtheunitcanstillalarmasusual.
NOTE: Thenormalstandbytimeofbatteryis5yearsminimum.Ifthereisaproblemwiththebatteryorlowbatterysignalwarning
keepsactivatingforover30days,replacethebattery.
7.9. MANUAL ZERO
7.9.1. InnormaloperationwithnoCOgaspresent,whentheLCDdoesnotshow“0PPM”,youcanpresstheTESTbuttondownfor3
secondsuntilthePPMcharacterontheLCDdisappears,thenreleasetheTESTbuttonuntiltheLCDshows“0PPM”.
7.9.2. Manual Zero can only be carried out under the following two conditions:
A:TheCOconcentrationontheLCDislowerthan10PPM.
B:TherstdigitoftheLCDshows“-”.
7.10. FAULT SIGNAL WARNING
7.10.1. Theunitwillself-testtheamplifyingcircuitandsensorevery10seconds.
Whenthereisaproblemwiththeamplifyingcircuitorsensor,theunit
willbeepevery30secondsalongwithayellowashingLED,theLCD
willshow“---”,seeg.7.
CO - LEVEL (PPM) RESPONSE TIME (MIN.) ALARM SOUND
30ppm-49ppm After 120 2continuouschirp(with1sfrequencychirp)
50ppm-99ppm 60-90 3continuouschirp(with1sfrequencychirp)
100ppm-299ppm 10-40 4continuouschirp(with1sfrequencychirp)
300ppmorabove 0-3 4continuouschirp(with0.5sfrequencychirp)
Flashes every 40
seconds
g.6
g.8
Flashes every 60
seconds
g.7
Flashes every 30
seconds
SCMA1 Issue 2 23/06/2020
Original Language Version
©JackSealeyLimited

7.11. END OF ALARM LIFE WARNING
7.11.1. Whenthealarmisattheendofitslife,itgivesthree“beep”audiblealarmsevery60secondstogetherwithaLEDvisualalarm,see
g.8.
7.12. CALIBRATION
7.12.1. Calibration can only be carried out by a professional organisation, please DO NOT calibrate it yourself.
7.12.2. Calibrationiscarriedoutonagasconcentrationof400PPM,thiswillnotaecttheunit’saccuracy,everyunithasbeencalibrated
before delivery.
7.12.3. PresstheTESTbuttondownuntilall3LEDsareon,thenreleasetheTESTbutton,thegreenandyellowLEDswillturno,onlythe
redLEDwillstayon.ItsigniesthatthealarmisnowinCalibrationMode.
7.12.4. Theunitwillnowgive5minutesinwhichitcanbecalibrated.
7.12.5. IftheunitcannotdetectanychangeofCOconcentrationwithin5minutesitwillautomaticallyexitCalibrationMode.
7.12.6. AftercalibratingonCOgas,the3LEDswillash3timesatthesametimetoindicatetheCalibrationwassuccessful.
NOTE: 1.TheunithasaminimumCOconcentrationforcalibrating(250PPMminimum).Ifthecalibrationiscarriedoutonaconcentration
lowerthan250PPM,theunitwillnotchangeitspreviouscalibrationvalues.
2.WhentheCOconcentrationontheLCDisbiggerthan30PPM,theunitwillstopenteringintoCalibrationModetoprevent
mis-operation.
3.IftheuseraccidentallyentersintoCalibrationModebychance,justpresstheTESTbuttontoexittheCalibrationMode.
7.13. WHEN THE CO ALARM RAISES AN ALARM
7.13.1. Immediatelymoveoutdoors,openalldoors/windowstoventilatetheareaandallowthecarbonmonoxidetodisperse.
7.13.2. Wherepossibleto,turnoanyfuelburningappliance.
7.13.3. Evacuate the building. DO NOTre-enterthepremisesormoveawayfromtheopendoor/windowuntilemergencyserviceshave
arrived,thepremiseshavebeenairedoutandyouralarmhasreturnedtoitsnormalcondition.
7.13.4. Seekmedicalhelpimmediatelyforanyonesueringfromsymptomsofheadache,drowsiness,nauseaetc.
8DO NOTusetheappliancesagainuntiltheyhavebeencheckedbyaqualiedtechnician,thefaultlocatedandrepaired.
8. MAINTENANCE
8.1. Replace the entire unit every 5 years.
8.1. YourdetectorwillalertyoutopotentiallyhazardousCOconcentrationsinyourhomewhenmaintainedproperly.
8.2. Tomaintainyouralarminproperworkingorderitisrecommendedthatyou:
•TestthealarmbypressingtheTESTbuttonatleastonceamonth.
•CleanyourCOalarmregularlytopreventdustbuildup.Thiscanbedonewithavacuumcleanerwiththebrushattachmentoncea
month.Cleangentlyaroundthegrillesandsides.
•Neverusecleaningsolutionsonthealarm,simplywipewithadampcloth.
8DO NOTpaintthealarm.
9. GAS SELECTIVITY
9.1. Thisalarmpossessconformitytoselectivitywhichinternationalstandardsrequireandthetablebelowshowstheselectivityto
gasesdenedinUL2034andEN50291.
TEST GAS RELATIVE SENSITIVITY (CO IS 100)
CO 100
Hydrogen 40
Methane 0
Iso-Butane 0
Carbon dioxide 0
Carbondi-sulfate 0
Hydrogensulde 0
Nitrogen Oxide 0
Nitrogen Dioxide Less than 5
Ammonia 0***
Ethyl acetate 0***
Di-chloromethane 0***
Heptane 0***
Toluene 0***
IPA 0***
Ethanol Less than 2*
Hexa-methyldi-siloxan 0**
Exposuretime*:30minutes**:40minutes***:2hours
SCMA1 Issue 2 23/06/2020
Original Language Version
©JackSealeyLimited

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk
ENVIRONMENT PROTECTION
Recycleunwantedmaterialsinsteadofdisposingofthemaswaste.Alltools,accessoriesandpackagingshouldbesorted,takento
arecyclingcentreanddisposedofinamannerwhichiscompatiblewiththeenvironment.Whentheproductbecomescompletely
unserviceableandrequiresdisposal,drainanyfluids(ifapplicable)intoapprovedcontainersanddisposeoftheproductandfluids
according to local regulations.
BATTERY REMOVAL SEE SECTION 7.1
UndertheWasteBatteriesandAccumulatorsRegulations2009,JackSealeyLtdarerequiredtoinformpotentialpurchasersofproducts
containingbatteries(asdefinedwithintheseregulations),thattheyareregisteredwithValpak’sregisteredcompliancescheme.Jack
SealeyLtdBatteriesProducerRegistrationNumber(BPRN)isBPRN00705.
Note:Itisourpolicytocontinuallyimproveproductsandassuchwereservetherighttoalterdata,specificationsandcomponentpartswithoutprior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty:Guaranteeis12monthsfrompurchasedate,proofofwhichisrequiredforanyclaim.
SCMA1 Issue 2 23/06/2020
Original Language Version
©JackSealeyLimited