1. SAFETY
2. INTRODUCTION
4. MOUNTING
3. BATTERIES
1.1. This alarm is a smoke detector of the photo cell principle. This means that the alarm checks the air for smoke resulting from re. It does
not detect heat, gas or re.
1.2. If the smoke detector is properly mounted and maintained it will sound an alarm at an early stage. In the event of a re it can give you
those extra seconds needed to vacate your home and call the re brigade.
1.3. The alarm is designed to detect smoke, it can not prevent a re.
1.4. Placing a smoke alarm is part of your re protection, just as: re extinguishers, emergency ladders, ropes, choice of materials used in
renovation are.
1.5. Always ensure that you have an evacuation plan, and discuss this with your children. Ensure that each room can be left without opening
the door, e.g. by the window. If there is any question as to the cause of an alarm, it should be assumed that the cause is an actual re
and the dwelling evacuated immediately.
1.6. DO NOT paint the smoke alarm.
3.1. The smoke detector works on one 9V DC battery. Normally the battery will last at least one year under normal conditions of use.
3.2. If the battery is at or almost at the smoke detector will indicate this with an audible “beep”. This indicator sounds continually with
intervals of 30-40 seconds for at least 7 days.
3.3. Replace the battery when this indicator sounds. Use a 9V alkaline DC battery of high quality.
3.4. Battery Replacement
3.4.1. Turn the alarm anticlockwise to remove it from the baseplate. Remove battery and replace ensuring connector is tted securely. Ret
to baseplate.
4.1. Where is the best place to mount smoke detectors?
•at least one in each room
• in the hallway, in the stairway
• in front of each bedroom door
• in each bedroom (if you sleep with door shut)
• in the living room
• in a storage room or spaces with electric equipment
4.2. The smoke alarm should not be mounted in:
• a room in which the temperature can reach below -4°C or above 40°C
• in damp spaces
• just in front of doors or windows and not near a ventilator or radiator
4.3. DO NOT mount the alarm in a place which is difcult to reach because of the need to reach the test button, to replace the battery and
carry out maintenance.
4.4. Mounting
4.4.1. Mount the alarm in the centre of the ceiling of the room.
4.4.2. Fix the base plate, using the screws provided, onto the area chosen. Refer to g.1.
4.4.3. Gently tighten the alarm onto the base plate.
Manufactured according to CE standards. Detachable composite facia, allowing the user to change the 9V battery (not included) when
required. Test function enables the operator to test the alarm and to help distinguish the alarm sound.
g.1

Environmental Protection
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be
sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.
When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)
into approved containers and dispose of the product and the fluids according to local regulations.
WEEE Regulations
Dispose of this product at the end of its working life in compliance with the EU Directive on
Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed
of in an environmentally protective way. Contact your local solid waste authority for recycling information.
Battery Removal
Refer to section 4.4.
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential
purchasersofproductscontainingbatteries(asdenedwithintheseregulations),thattheyareregisteredwithValpak’s
registeredcompliancescheme.JackSealeyLtd’sBatteriesProducerRegistrationNumber(BPRN)isBPRN00705.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
01284 703534
sales@sealey.co.uk
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
www.sealey.co.uk
Original Language Version
© Jack Sealey Limited
5.1. The alarm has a test button, press this until the alarm signal sounds. Test the alarm at least once a week and after replacing the battery
or after cleaning.
5.2. The alarm must be vacuumed regularly to remove dust particles and to protect the alarm. Keep the casing closed whilst cleaning.
5.3. If the alarm fails to operate correctly, contact your dealer.
5. OPERATION