SMOKE ALARM
MODEL NO: SFAL01
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
9This alarm is a smoke detector of the photo cell principle. This means that the alarm checks the air for smoke resulting from re. It
does not detect heat, gas or re.
9If the smoke detector is properly mounted and maintained it will sound an alarm at an early stage. In the event of a re it can give you
those extra seconds needed to vacate your home and call the re brigade.
9The alarm is designed to detect smoke, it can not prevent a re.
9Placing a smoke alarm is part of your re protection, just as: re extinguishers, emergency ladders, ropes, choice of materials used in
renovation are.
9Always ensure that you have an evacuation plan, and discuss this with your children. Ensure that each room can be left without
opening the door, e.g. by the window. If there is any question as to the cause of an alarm, it should be assumed that the cause is an
actual re and the dwelling evacuated immediately.
8DO NOT paint the smoke alarm.
2. INTRODUCTION
Certied to BS EN14604:2005 + AC1:2008. Detachable composite facia, allowing the user to change the 9V battery (not included) when
required. Fire Service advises to replace this type of alarm after 10 years.
3. BATTERIES
3.1. The smoke detector works on one 9V DC battery. Normally the battery will last at least one year under normal conditions of use.
3.2. If the battery is at or almost at the smoke detector will indicate this with an audible “beep”. This indicator sounds continually with
intervals of 30-40 seconds for at least 7 days.
3.3. Replace the battery when this indicator sounds. Use a 9V alkaline DC battery of high quality.
3.4. BATTERY REPLACEMENT
3.4.1. Turn the alarm anticlockwise to remove it from the baseplate. Remove battery and replace ensuring connector is tted securely. Ret
to baseplate.
4. MOUNTING
4.1. WHERE IS THE BEST PLACE TO MOUNT SMOKE DETECTORS?
REFER TO FIG.2
•at least one in each room
• in the hallway, in the stairway
• in front of each bedroom door
• in each bedroom (if you sleep with door shut)
• in the living room
• in a storage room or spaces with electric equipment
4.2. THE SMOKE ALARM SHOULD NOT BE MOUNTED IN:
• a room in which the temperature can reach below -4°C or above 40°C
• in damp spaces
• just in front of doors or windows and not near a ventilator or radiator
8DO NOT mount the alarm in a place which is difcult to reach because
of the need to reach the test button, to replace the battery and
carry out maintenance.
4.3. MOUNTING
4.3.1. Mount the alarm in the centre of the ceiling of the room.
4.3.2. Fix the base plate, using the screws provided, onto the area chosen. Refer to g.1.
4.3.3. Gently tighten the alarm onto the base plate.
Refer to
instruction
manual
Original Language Version
© Jack Sealey Limited SFAL01 Issue:2 (H,F) 26/06/20
g.1