NOVASUB - DDG-P QUICKSTART GUIDE - R1.1
WWW.NOVASUB.COM
R1.0 1 of 2
Manufactured by Seascape.nl
Action
Description
Needed
Installation
•Connect both probe cables and probes to the SCC-DDG-P side
panel
•Connect external 100-230 vac power
2x UDS-2 pressure
sensor with cables
Power Up
Press Power button to start the DDG
Calibration
preparations
•Place both sensors vertical together
•Connect the measuring tap 0 on the measuring point of the sensors
•Make sure that both cables are long enough so that the pressure
sensors can be lowered to the max. calibration point
Measuring tape
Initial calibration
(Do the initial
calibration on each
new project
location)
1. Press Menu and go to Maintenance Admin settingsLogin
Admin
2. Type password: OK+--+OK and OK again
3. Go to Menu Calibrations in Admin settings Menu
4. Select P1 and P2 and press OK
5. With Both pressure sensor in the air above and out of the water
press, OK
6. Lower down both Pressure sensors to the max. calibration depth
and read the exact depth at the measuring tape water surface line.
7. Enter the value in millimetres , use + and –buttons to select value
and press OK to go to next digit. Press OK after last digit.
8. Make sure pressure sensors are on the entered water depth, Press
OK to set the WCcalMax.
9. Reboot the DDG-P
Reference point
NAP-ref.
(Reference point of
the project to which
p1 if referenced to)
1. Press Menu and go to Maintenance Admin settingsLogin Admin
2. Type password: OK+--+OK and OK again
3. Go to Menu Calibrations in Admin settings Menu
4. Select Config NAP ref and press OK
5. Enter the value in millimetres , use + and –buttons to select value
and press OK to go to next digit. Press OK after last digit.
Installing P1
P1 needs to be placed vertical in water approx. 0,5 m below water level
and deep enough that the water level never gets below the depth
sensor.
•Measure the exact distance from bottom of P1 to NAP-ref. point
Measuring tape
Level P1 settings
1. Login in Admin settings Menu
2. Go to Menu Calibrations in Admin settings Menu
3. Select Config Level P1 and press OK
4. Enter the value of Level-P1 in millimetres , use + and –buttons to
select value and press OK to go to next digit. Press OK after last
digit.
P-offset
The P-offset is fixed for the standard supplied UDS-2 sensor. Do not
change.
Logging
1. The “Dive monitor” shows “ Press OK to start log” on the display
2. Start the next log by pressing OK
3. To log a point Press OK
4. Continue Pressing “OK” to log a new point
5. Stop logging by pressing “MENU” and “OK”
6. Logfile: X shows the file number and Point: x shows the point
number in the logfile. Each point is stored in the file with all data.
NOVASUB - DDG-P QUICKSTART GUIDE - R1.1
WWW.NOVASUB.COM
R1.0 2 of 2
Manufactured by Seascape.nl

Popular Measuring Instrument manuals by other brands

Eaton LifeSense Quick setup guide

Eaton

Eaton LifeSense Quick setup guide

Elster F96Plus Installation and user guide

Elster

Elster F96Plus Installation and user guide

AETOOL BESA 12 user manual

AETOOL

AETOOL BESA 12 user manual

Electron MPO-02 user manual

Electron

Electron MPO-02 user manual

FISCHER MS11 instruction manual

FISCHER

FISCHER MS11 instruction manual

LEGRAND IME NEMO D4-e installation manual

LEGRAND

LEGRAND IME NEMO D4-e installation manual

PCB Piezotronics IMI SENSORS 623C11 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 623C11 Installation and operating manual

Protean Instrument MPC-1000 series user manual

Protean Instrument

Protean Instrument MPC-1000 series user manual

AQUASOL AB-T-TDS instruction manual

AQUASOL

AQUASOL AB-T-TDS instruction manual

UEi DL599 instruction manual

UEi

UEi DL599 instruction manual

AEMC JM830A user manual

AEMC

AEMC JM830A user manual

McCrometer McMAG 2000 Quick start installation guide

McCrometer

McCrometer McMAG 2000 Quick start installation guide

UEi DL419 instruction manual

UEi

UEi DL419 instruction manual

PROZIS Kgo user manual

PROZIS

PROZIS Kgo user manual

otometrics Bio-logic NavPRO ONE quick start guide

otometrics

otometrics Bio-logic NavPRO ONE quick start guide

insize ISQ-TS120K Operation manual

insize

insize ISQ-TS120K Operation manual

Endress+Hauser FQG66 operating instructions

Endress+Hauser

Endress+Hauser FQG66 operating instructions

Turner Designs TD-5100 ECA manual

Turner Designs

Turner Designs TD-5100 ECA manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.