manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SECO-LARM
  6. •
  7. Security Sensor
  8. •
  9. SECO-LARM ENFORCER SECURITY SS-040Q User manual

SECO-LARM ENFORCER SECURITY SS-040Q User manual

ENFORCER Shock/Vibration Detector
4 SECO-LARM U.S.A., Inc.
WARRANTY
This SECO
-
LARM product is warranted against de ects in material and workmanship while used in normal
service or a period o one (1) year rom the date o sale to the original consumer customer. SECO-LARM’s obligation is
limited to the repair or replacement o any de ective part i the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void i damage is caused by or attributed to acts o God, physical or electrical misuse or abuse, neglect,
repair, or alteration, improper or abnormal usage, or aulty installation, or i or any other reason SECO-LARM determines
that such equipment is not operating properly as a result o causes other than de ects in material and workmanship.
The sole obligation o SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only,
at SECO-LARM’s option. In no event shall SECO-LARM be liable or any special, collateral, incidental, or consequential
personal or property damages o any kind to the purchaser or anyone else.
NOTICE: The in ormation and speci ications printed in this manual are current at the time o publication. However, the
SECO-LARM policy is one o continual development and improvement. For this reason, SECO-LARM reserves the right
to change speci ications without notice. SECO-LARM is also not responsible or misprints or typographical errors.
Copyright © 2011 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in
whole or in part, without the written permission o SECO-LARM.
SECO
SECOSECO
SECO-
--
-LARM
LARMLARM
LARM U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Website: www.seco-larm.com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
E-mail: sales
@
seco-larm.com
Mi
SS
-
040Q_
1110
.docx
Order Part # 763-020-3%
PITSW
1
Also Available from
SECO
-
LARM
:
Entry Alert System
E
-
93 CS22RRCQ
Audio Discriminator
•
For monitoring an entrance or use as an
entrance indicator
•Retro-re lective beam sensor.
•Range up to 22 eet.
E
-
90
•
Covers an area 45 eet in ront and
25 eet to either side.
•Incorporates SECO-LARM’s
patented yellow turbulence LED.
Twin
or
Quad
Photobeam Detector
s
E
-
964
-
D90Q
•
Twin beams available in ranges up to
90, 190, 290, and 390 eet.
•Quad beams available in ranges up to
165, 330, 495, and 660 eet.
Reflective
-
Beam Sensor
E
-
93
-
S35
RRQ
•
For garage doors, outdoor gates or overhead
doors or as a sensor or industrial automation.
•Weatherproo (IP66) design or indoor/outdoor
applications
(shown)
SECO
-
LARM carries a complete line o
security products.
For more in ormation please visit www.seco-larm.com
MANUAL
SS-040Q
Mini Shock/Vibration Detector
The ENFORCER
SS
-
040Q MINI SHOCK/VIBRATION DETECTOR
is designed or protection
against orced entry by a hammer, saw, crowbar, etc. through walls, ceilings, windows, sa es,
cabinets, etc. For use in closed-circuit alarm systems, the SS-040Q will initiate an alarm when
a vibration o considerable orce strikes the protected sur ace. A built-in tamper switch is
independently wired rom the vibration detector or enhanced security.
Vibration contacts are adjustable by turning an adjustment screw to respond on any sur ace -
glass, wood, steel, plasterboard, or brick. Pure silver contact points ensure years o long-term
operation. Dust-tight ABS case is small and can be easily mounted inside with two-sided
adhesive tape.
NOTE: Products with model numbers that end with “Q” or that have a round green “Q” sticker are RoHs compliant.
ENFORCER Shock/Vibration Detector
2 SECO-LARM U.S.A., Inc.
FEATURES
INSTALLATION AND OPERATION
SPECIFICATIONS
Circuit:
Normally
-
closed contact, momentarily open when activated
Contact Pressure:
Adjustable rom 1 to 50 grams but recommended setting between
5 and 25 grams only. Supplied with pressure o approx. 6 grams
Current Rating:
1A @
50VDC.
Break Time:
Approx. 45 ms max. (at 6
-
gram pressure)
Life:
Over 100,000 contacts
Contact:
Pure silver
Case:
ABS resin
Size:
15mm (H) x 21mm (W) x 60mm (L)
Weight: 20 gms
2.
I you choose not to use the tamper switch,
asten the wire to the terminal
arther rom the
opening, as shown below.
•
For use in closed
-
circuit alarm systems.
•
Pure silver contacts ensure reliable and
long-term operation.
•
Ideal or protecting glass windows,
showcases, solid walls, ceilings, sa es,
cabinets, motorcycles, skylights, etc.
•
Small size and or discreet installation.
•
Built
-
in tamper switch provides enhanced
security.
•
Adjustable contact pressure or di erent
sur aces.
•
Detects a vibration/shock on protected
sur ace and activates an alarm.
1.
Remove the cover and connect one lead o the wire rom the N.C. input o the alarm to the
terminal o the SS-040Q near the opening. Connect the other lead to the terminal o the
t
a
mper switch, as shown below
.
The
SS
-
040Q
will trigger the alarm whenever it is vibrated
,
shaken
,
or its cover is removed.
The alarm will trigger only
when the
SS
-
040Q
is vibrated
or
shaken
.
NOTE:
When protecting windows the pre erred installation method is to
mount the
SS
-
040Q
on the rame o the glass window rather than directly on the glass. This reduces the
chance o alse alarms resulting rom heavy vehicles passing by or rom inadvertent
tapping on the window by pedestrians.
To alarm unit
Close loop input
Close loop input
To alarm unit
ENFORCER Shock/Vibration Detector
SECO-LARM U.S.A., Inc 3
HOW TO ADJUST THE SENSITIVITY
Contact pressure below 5 grams is not recommended, as erratic operation may result and
cause alse alarms. Contact pressure above 25 grams is not recommended because (a) it may
permanently damage the vibration blade; (b) the detector may not be sensitive enough to
detect vibration. This depends on the location where the detector is installed. I installed on a
ceiling the pressure must be increased. Because the internal weight aces downwards, this
reduces the pressure that is applied.
As the SS-040Q can be used sur aces o di erent materials which trans er di erent amounts
o pressure rom the same vibration/shock, it may be necessary to adjust the sensitivity.
Turning the adjustment screw (a) in a clockwise direction makes the contact less sensitive, (b)
in a counterclockwise direction makes the contact more sensitive. Proper adjustment may be
necessary to avoid alse alarms or non-activation o the alarm.
To adjust the pressure i a Gram Meter is not available, please do the ollowing:
1. Determine the initial contact point o the vibration detector. This is done by rotating the
adjustment screw in a clockwise direction until the contact points just touch. At this point the
pressure is usually approx. 1 gram. (An ohm meter placed across the terminals will show
exactly when initial contact is made.)
2. A ter contact, turn the adjustment screw past the contact point (a) 45 degrees to obtain
approximately 6 grams, (b) 90 degrees to obtain approximately 11 grams, (c) 135 degrees
to obtain approximately 16 grams, etc. to obtain the sensitivity you require. Please use
igure 1 shown below.
Figure 1: Adjusting Vibration Detector Pressure

Other SECO-LARM Security Sensor manuals

SECO-LARM E-960-D90GQ User manual

SECO-LARM

SECO-LARM E-960-D90GQ User manual

SECO-LARM Enforcer series User manual

SECO-LARM

SECO-LARM Enforcer series User manual

SECO-LARM ENFORCER 190 User manual

SECO-LARM

SECO-LARM ENFORCER 190 User manual

SECO-LARM ENFORCER RM-R100-TBQ User manual

SECO-LARM

SECO-LARM ENFORCER RM-R100-TBQ User manual

SECO-LARM ENFORCER E-964-Q660Q User manual

SECO-LARM

SECO-LARM ENFORCER E-964-Q660Q User manual

SECO-LARM SLI Enforcer E-964-D390Q User manual

SECO-LARM

SECO-LARM SLI Enforcer E-964-D390Q User manual

SECO-LARM E-931CS22RRCQ User manual

SECO-LARM

SECO-LARM E-931CS22RRCQ User manual

SECO-LARM SLI Enforcer SS-040Q User manual

SECO-LARM

SECO-LARM SLI Enforcer SS-040Q User manual

SECO-LARM SLI Enforcer E-964-D390Q User manual

SECO-LARM

SECO-LARM SLI Enforcer E-964-D390Q User manual

Popular Security Sensor manuals by other brands

CropX V02 installation guide

CropX

CropX V02 installation guide

Toshiba GF630 instruction manual

Toshiba

Toshiba GF630 instruction manual

schmersal SFB-PN-IRT-8M12-IOP operating instructions

schmersal

schmersal SFB-PN-IRT-8M12-IOP operating instructions

LST 5251EM Specification sheet

LST

LST 5251EM Specification sheet

ESYLUX COMPACT APC10 DALI-2 user manual

ESYLUX

ESYLUX COMPACT APC10 DALI-2 user manual

HELVAR OB-1501 installation guide

HELVAR

HELVAR OB-1501 installation guide

Eaton 1450-CSA Instruction leaflet

Eaton

Eaton 1450-CSA Instruction leaflet

Exotek Instruments BDD mini user manual

Exotek Instruments

Exotek Instruments BDD mini user manual

Conrad Electronic FS20 PIRI operating instructions

Conrad Electronic

Conrad Electronic FS20 PIRI operating instructions

Inficon IRwin Series quick start guide

Inficon

Inficon IRwin Series quick start guide

Terrier FHX owner's manual

Terrier

Terrier FHX owner's manual

Vega Absolute Smart-MS0101 user manual

Vega Absolute

Vega Absolute Smart-MS0101 user manual

Horotec Magtest MSA 19.910 manual

Horotec

Horotec Magtest MSA 19.910 manual

AMC AMC-1225 instructions

AMC

AMC AMC-1225 instructions

jablotron JA-160PC quick start guide

jablotron

jablotron JA-160PC quick start guide

Kistler 5335A Series instruction manual

Kistler

Kistler 5335A Series instruction manual

Goldak 777-A quick guide

Goldak

Goldak 777-A quick guide

B.E.G. 93386 quick start guide

B.E.G.

B.E.G. 93386 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.