1. CODE.START (Manage transmitter code start)
The control unit can learn up to 200 transmitters with fixed or rolling codes.
Same function with control unit [10-11] START command input .
Learn codes:
Press [SEL] key brief until [CODE.START] LED flash , press and hold the
transmitter correspond button you want to learn , when [CODE.START]
LED stop flash and light on , learn procedure finish . When all function
LEDS flash , it means memory is full and can’t learn more transmitter.
Erase all codes:
Press [SEL] KEY brief until [CODE.START] LED flash, press and hold
[SET] key until [CODE.START] LED light off , all codes in memory will
erased , erase procedure will finish .
2. CODE.PEDE (Manage transmitter code pedestrian)
The control unit can learn up to 200 transmitters with fixed or rolling codes.
When pedestrian mode on , the gate will open for 10 seconds , then pause
for 10 seconds and gate will close again.
Setting function same with [CODE.START] .
3. P-P/DIS-OP (Command disable during opening and pause)
The command disable during opening and pause function suitable used for
automatic closure with loop detect. During opening and pause , control unit
ignore the command given by loop detect .
Press [SEL] key brief until [P-P/DIS-OP] LED flash , press [SET] key brief.
[P-P/DIS-OP] LED light on , command disable during opening and pause.
[P-P/DIS-OP] LED light off , command mode is step-by-step.
4. LAMP.CORT (Flash lamp or Courtesy light select)
When every opening command is given ,Courtesy light output mode :
230V lamp will activate for 3 minutes then off.
230V lamp will activate when motor is runningFlash lamp output mode :
or pause time , else 230V lamp is off.
Press [SEL] key brief until [LAMP.CORT] LED flash , press [SET] key brief.
[LAMP.CORT] LED light on , 230V lamp output mode is courtesy light.
[LAMP.CORT] LED light off , 230V lamp output mode is flash lamp.
5. (Motor self-learning , max timer 4 minutes)T.MOTOR
The control unit default motor operation time is 30 seconds , without
slow-down function.
Press [SEL] key brief until [T.MOTOR] LED flash , press [SET] key brief
, motor will run opening ; when the slow-down initial point is reached ,
press [SET] key brief again , motor will run in slow-down ;when total
opening point is reached , press [SET] key brief , motor will stop and
opening self-learning is complete , [T.MOTOR] LED start flash rapidly.
Repeat self-learning procedure for motor closing cycle , total motor
self-learning procedure will finish.
6. (Automatic closure pause time , max 4 minutes)T.PAUSE
The control unit default without automatic closure function .
Press [SEL] key brief until [T.PAUSE] LED flash , press [SET] key brief and
wait for the desired pause time , then press [SET] key brief again , the
automatic closure pause time is stored and [T.PAUSE] LED will light on.
External Menu 1 LED indicated:
Enter External Menu 1 :
When control unit current in standby menu , press and hold [SET]
key over 5 seconds , the [T.PAUSE] and [T.MOTOR] LEDS flash
alternately , now enter External Menu 1.
Exit to Standby Menu :
When enter External Menu 1 , over 30 seconds without [SEL] or
[SET] key press , control unit will return back to standby menu .
CODE.START
CODE.PEDE
P-P/DIS-OP
LAMP/CORT
T.MOTOR
T.PAUSE
LED OFF LED ON
[T.PAUSE] and [T.MOTOR]
LEDS flash alternately
Electronics brake off Electronics brake on
Pressure maintenance off Pressure maintenance on
Remote PGM off
Step-by-Step Input invert
Remote PGM on
[T.PAUSE] and [T.MOTOR]
LEDS flash alternately
1. CODE.START (Transmitter learn via radio control)
The control unit allow to enter learn transmitter function via radio control .
Press and hold the transmitter correspond button that already learn over 10
seconds , the standby menu [CODE.START] LED flash , now can learn new
transmitter .
2. CODE.PEDE (Step-by-Step or Input invert select)
Input invert means when motor opening , press transmitter button or low
voltage push button brief , motor reverse to run closing immediately .
Same when run closing , immediately reverse to run opening .
To cancel slow-down function of self-learning , when motor running at
the desired point of opening or closing , press [SET] key twice brief in
2 seconds , instead of press once .
To cancel automatic closure pause time , press [SEL] key brief until
[T.PAUSE] LED flash , press [SET] key twice brief in 2 seconds , [T.PAUSE]
LED light off and operation finish .
Press [SEL] key brief until [CODE.START] LED flash , press [SET] key brief.
[CODE.START] LED light on , allow transmitter learn via radio control .
[CODE.START] LED light off , disable transmitter learn via radio control .
Press [SEL] key brief unitl [CODE.PEDE] LED flash, press [SET] key brief
[CODE.PEDE] LED light on , input mode is invert input .
[CODE.PEDE] LED light off , input mode is Step-by-Step .