Secureye S-16GE-2UG-LD-AI-VLAN User manual

User Manual
S-16GE-2UG-LD-AI-VLAN
16 port Gigabit AI POE Switch

Instruction manual
《User Manual》mainly introduce S-16GE-2UG-LD-AI-VLAN hardware feature,
installment method and attention items.
Including these section:
The first section:product introduction. Mainly introduce POE switch function, feature
and appearance.
The second section:product installment. Guide POE switch hardware installment
method and attention items.
The third section:hardware connection. Guide POE switch connection with other
device and attention items.
The forth section:technical specification.
Delare:In order to avoid device is damaged and personal injury, please carefully
read user manual correlation content.
Appointment
Part pictures are diagrammatic drawing, the picture can exsit difference with product.
The icon remind the attention items, if the incorrect operation can cause the device is
damaged

The first section Product Introduction
1.1Product Profile
S-16GE-2UG-LD-AI-VLAN is gigabit AI POE switch, 16 10/100/1000Mbps
POE port with2 Gigabit SFP Ports. S-16GE-2UG-LD-AI-VLAN can carry
power to IP camera, wireless AP, wireless bridge, IP phone.S-16GE-2UG-
LD-AI-VLAN is with 4 working mode, In AI VLAN mode, 1 -16 ports are isolated from
each other, which can effectively restrain network storms and improve network
performance. In AI Extend mode, the effective transmission distance of 1-8 ports can
reach 250 meters, which is suitable for remote monitoring and power supply. In the AI
power supply mode, the switch automatically detects the working status of the PD
device and finds that the device abnormal automatically restarts the device. In AI
QOS mode: the video data will be processed preferentially when the device is
congested to make the video smoother S-16GE-2UG-LD-AI-VLAN support
IEEE802.3af/at , auto identification power device, so don’t worry it will destroy the
private standard POE or non-POE device.
1.2 Package content
Opening packing box, please carefully check the following content
Content
Quantity
Declaration
POE switch
One piece
\
Power cord
One piece
Supply power
Bracket
Two piece
Rack mounted
User manual
One piece
Install guide

1.3 Product Appearance
◼Front panel
Including indicator light, RJ45 port, DIP switch, SFP port, the picture is as follow:
Indicator light
S-16GE-2UG-LD-AI-VLAN indicator light working information is as follow:
LED
Name
Color
Working
states
Declaration
POWER
Power LED
Red
ON
power normally
Off
Don’t have power、power switch
don’t turn on, power abnormal
LINK/ACT(17
18)
Device
connection
LED
Green
blink
Corresponding already connect
normally
Off
Corresponding port don’t connect
normally
RJ45 Port
S-16GE-2UG-LD-AI-VLAN support 16 port 10/100/1000Mbps,IEEE802.3af,
IEEE802.3at standard POE supply power. When working mode is Extend mode, port1-
port 8 can support 250m supply power
SFP Port
S-16GE-2UG-LD-AI-VLAN is with two gigabit SFP port(17,18), use for gigabit SFP
module.
Working mode key
AI Extend: 1-8 port supports 250M meters long distance power supply (recommended cat 5
or above)

AI VLAN: Isolating ports 1-16 from each other, restrain network storms effectively and
improve network performance
AI QOS: Prioritize the identified video data to make video transmission smoother
AI PoE: Automatic detection power of port, power off and restart the device if find
◼Rear panel
Including:Power socket、ground terminal
Power socket
Connection power cord to POE switch S-16GE-2UG-LD-AI-VLAN power supply is
AC100-240V~50/60Hz.
Ground terminal
Please use guide line ground connection, in case lighting stroke. In order to avoid
the product sustain lighting stroke and extend using lifetime.
The second section Product Install
1.1 Install attention items
Attention:Avoid incorrect using caused device is damaged and personal injure,
please carefully read the following of attention items
◼The install safety attention items
⚫During install make sure power supply keep turn off states, put on anti-
static wrist , guarantee the anti-static wrist have good touch with skin,
avoiding the potential safety loophole;
⚫POE switch can work normally under the correct power supply, please
confirm the supply power voltage is correspond with the marked voltage;

⚫Before POE switch supply power, please confirm it won’t cause power
supply circuit overload, for fear that affecting POE switch work normally,
even cause unnecessary destroy;
⚫Avoiding electric shock dangerous, please don’t open the casing when
POE switch work, even if without power condition, don’t open the casing
too;
Before clean POE switch, should pull out power plug,
please don’t use wet cloth scrub, please don’t use liquid cleaning;
Temperature Humidity
In order to insure PoE switch long-term steady operation, extend using
lifetime, please maintenance a certain temperature and humidity. too high
or too low过environment humidity easier to cause insulation material
electric leakage, variant , even metal parts rusting, high temperature
speed up insulation material aging processing, seriously affect device use
lifetime. The POE switch working temperature and storage temperature/
humidity is as follow:
Environment
Description
Temperature
relative humidity
Working
environment
0℃~40℃
10%~90% RH
non condensing
Storage
environment
-40℃~70℃
5%~90% RH
non condensing
Elevation
The product is with this icon just only use for the less than elevation 2000m area
safety using.
Dustproof
Dust fall over POE switch surface can cause electrostatic adsorption,
make metal connection point poor touch. Although the product make a
certain measure of anti static, when static electricity exceed a certain
strength, still destroy component parts of the PCB, in order to avoid static
electricity affect product work normally, please pay attention to the items
as follow:
regularly clean dust, keep indoor air cleaning;
insure device ground good, guarantee static electricity transfer smoothly

Electromagnetic interference
Electromagnetic interference can affect the device internal capacitance,
inductance, in order to reduce electromagnetic interference factor cause
adverse effect, please pay attention to the following of items:
Supply power system adopt necessary anti power grid interference
measure;
PoE switch should be far away from high frequency power, high current
device, such as wireless launch pad;
If necessary, please make electromagnetic shielding measure
Lighting protection requirement
When lighting strike, in the moment will have a strong current, the air on
the discharge path will be instantly heated to 20000 celsius degrees, in the
moment high current enough to cause fatal damage to electronic
equipment.
In order to reach better lightning protection effect, please not the following:
Make sure the rack is in good touch with the ground;
Make sure the power socket is in good touch with the ground;
Reasonable wiring to avoid internal lightning;
Outdoor wiring, it is recommended to use signal lightning protector;
Installation platform requirment
POE switch is installed in a rack or on another horizontal workbench,
Please note the following:
Make sure rack or workbench smooth and steady, secure, it can bear
5.5kg weight at least;
Make sure the rack has a good cooling system,or keep indoor well-
ventilated;
Make sure the rack is well grounded, power socket and POE switch don’t
exceed 1.5meter
Installation tools ready
During installation, may be used screwdrivers, antistatic wrist strap, network
cable , fiber tools, please the user self-prepare;

2.2 Product Installation
1. S-16GE-2UG-LD-AI-VLAN is designed according to the standard 19-inch rack size, you
can easily install to the rack, the specific installation steps are as follows:
2. check the rack grounding and stability;
3. two pieces L type bracket differentiate install to the two sides of POE switch
panel and fix with screw
4. Put POE switch on the appropriate location of the rack, crutch by bracket;
using the L-shaped bracket to fix the two sides of rack with screw, make
sure POE switch is installed on the rack smooth and steady.
5. Attention:
Rack has well grounded is the important guarantee of anti-static , anti-
leakage,lightning protection,anti-interference, so make sure the rack ground
wired is properly installed;
Rack-mounted device generally from down to up, avoid overload Installation;
Don’t put heavy things on the POE switch, in case happen accident;
Make sure cooling and air ventilation

The third section hardware connection
3.1 Connection RJ45 port
Using Ethernet cable connect POE switch to the RJ45 port of the opposite end
network device, default the POE switch’s downlink port already open POE power
function, it can send power to IP camera, wireless AP, wireless bridge.
Attention:
When POE switch is connected to a workstation,server,router, or other Ethernet
device, the Ethernet cable length can not more than 100meter;
The Ethernet RJ45 port Auto-MDI/MDIX function default open, when adopt Cat.5
cable to connect Ethernet network, both standard Ethernet cable and crossover
Ethernet cable can be used;
Don’t use RJ45 port to connect telephone cable.
3.2 Connection SFP port
S-16GE-2UG-LD-AI-VLAN SFP port just only support gigabit SFP module.
Suggestion to use standard SFP module.
The process of POE switch install SFP module is as follow:
1. Hold the SFP module from the side, insert it smoothly along the SFP port
slot of POE switch, until the SFP module is close touch with POE switch;

2. When connection, please confirm SFP module RX and Tx port, the side of
fiber optic corresponding insert Rx and Tx port, Make sure Tx and Rx port
connection correctly, the another side of fiber connect to another device;
3. after powered,please check the corresponding indicator light status. If
light is on, show the link already connect normally, light is off, show the link
is blocked. Please check circuit, confirm the opposite end device already
start using.
Attention:
Do not over bend the fiber, the radius of curvature should not be less than
10cm;
Make sure the cleanliness of the fiber surface;
Please do not look directly at the fiber optical connector, otherwise can
cause eye damage.
3.3 Inspection Before powered
Please check if power socket supply power is correspond the specification or not;
Please check if power supply, POE switch, rack already grounded correctly or not;
Please check if PoE switch normally connect with other network equipment or not;
3.4 Device initialization
After powered after turn on power, POE switch will automatically initialization.
Indicator light will appear the following of situation;
After powered, the power indicator light always keep ON, the other indicator light
OFF.
After around two second, except power indicator light, the other indicator light ON
around two second, then OFF;
Each port indicator light indicates the connection status of each port, it show
POE switch start work normally.

The forth section product hardware specification
4.1 hardware specification
Standard
IEEE 802.3i IEEE 802.3u IEEE 802.3x
IEEE 802.3ab IEEE 802.3af IEEE 802.3at
Port
16 10/100/1000Mbps RJ45 ports
2 Gigabit SFP ports
PoE
16 10/100Mbps RJ45 PoE ports
Total power budget: 150W
Single port max. 30W
Indicator
18 Link/Act indicator light
16 POE indicator light
1 Power indicator light
Performance
forwarding mode:storage forwarding
Bankplane bandwidth:36Gbps
Packet forwarding rate:23.8Mpps
Support 8K MAC address list depth
Input power
100-240V/50-60Hz
Dimensions
(L×W×H)
440mm×180mm×44mm
Table of contents
Other Secureye Switch manuals