seikoh giken SFP-550 User manual

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA
SFP-550
Maintenance Manual
296-1 MATSUHIDAI, MATSUDO-CITY, CHIBA 270-2214 JAPAN
TEL: +81-47-388-6111 FAX: +81-47-388-4477
Product data subject to change
without notice.
MAINTENANCE MANUAL
Manufacturer:
Seikoh Giken
Product Name:
Seikoh Giken SFP-550C Series High Duty Cycle Polishing Machine
Manufacturer Part Number:
SFP-550C
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA Product data subject to change
without notice.
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine
SFP-550 Maintenance Manual
Introduction
This manual covers items and procedures for the periodic inspection required
for the SFP-550 Polishing Machine. At the periodic inspection or in the event
of problems arising, read this manual and familiarize yourself with the machine
before maintaining it. Make sure that power is off when performing inspections
or maintenance on the machine.
Note
This manual covers maintenance of the SFP-550 when used in accordance with
SFP-550 Polishing Machine Operating Manual. Read the Operating Manual and
the Polishing Process Manual along with this manual also. Please contact us
or our agents if you have any question or problem not covered by this manual.
1/15
SEIKOH GIKEN Co., Ltd.

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA Product data subject to change
without notice.
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine
SFP-550 Maintenance Manual
~~~~~~~~ Contents ~~~~~~~~
§§1
Inspection
1-1 Functioning Inspection
---------------------- 3
1-2 Regular inspection and maintenance
1-2-1 Grease check in the drive unit
1-2-2 Dimension check for the turntable and others
1-2-3 Pressurizing unit check
---------------------- 5
§§2
Treatment for unusual conditions
2-1 Unusual sound
§2-1-1 Eccentric ring checking
---------------------- 10
2-2 The turntable doesn’t move smoothly
§2-2-1 Gear unit checking
§2-2-2 Eccentric plates removal
---------------------- 11
§§3
Mechanical Structure
3-1 Mechanical Components
---------------------- 13
3-2 Structure Schematic
---------------------- 15
2/15
SEIKOH GIKEN Co., Ltd.

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA Product data subject to change
without notice.
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine
SFP-550 Maintenance Manual
§§••Inspection
1-1 Functioning Inspection
At the first starting or operating the machine after your purchase or any
problem arising, conduct performance inspection as outlined below.
Power cable plugging
Make sure an adaptation of electrical specifications before plugging
in a power cable.
Timer setting
Make sure the scales on the timer are set as [min] and [×1] .
Power Switch ON
- Does the pilot lamp (red) light on?
- Is the cooling fan runing?
Timer Switch ON
- Does the [PW] lamp on the timer light on?
- Do the pilot lamp (red and green) light on?
- Does the turntable begin revolution and rotation?
- Does the cooling fan keep running?
3/15
SEIKOH GIKEN Co., Ltd.

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA Product data subject to change
without notice.
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine
SFP-550 Maintenance Manual
Time Up
- Does the [PW] lamp on the timer go out?
- Does the pilot lamp (red) go out?
- Does the turntable stop revolution and rotation?
- Does the cooling fan keep running?
Power Switch OFF
- Do all the lamps on the front panel go out?
- Does the cooling fan stop running?
-
4/15
SEIKOH GIKEN Co., Ltd.

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA Product data subject to change
without notice.
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine
SFP-550 Maintenance Manual
1-2 Regular inspection and maintenance
Critical points in a principle of polishing withSFP-550 Polishing Machine are
following:
1. Polishing track of ferrule by revolution and rotation of the turntable
2. Pressure of polishing (the space between the clamping postson the
four corners and the turntable, the protrusion length of ferrules from the
bottom side of the polishing holder)
Read and familiarize yourself with the followings before inspection.
1-2-1 Grease check in the drive unit (once a month or for every100-500 driving
hours)
Remove the turntable and check the drive unit if it is full up with grease.
See Figure 1-2-1.
1-2-2 Dimension check for the turntable and others (once for 3 months or for
500-1000 driving hours)
Check the space between the clamping posts on the four corners and the turntable.
••The space between each clamping post and the turntable: 5.5•
•0.02mm
See Figure 1-2-2.
1-2-3 Pressurizing unit check (once for 6 months or for every1000-2000 driving
hours)
Check the free length of the pressurizing coil springs installed in the clamping posts.
••The free length of the pressurizing coil springs (P/N: RP55-20): 14•
•1mm
See Figure 1-2-3.
5/15
SEIKOH GIKEN Co., Ltd.

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA Product data subject to change
without notice.
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine
SFP-550 Maintenance Manual
Figure 1-2-1: Grease check in the drive unit
The turntable can be removed as it is lifted up.
Make sure that the drive unit is full up with grease.−
− If there is any space in the hatching part of the figure below, fill it up with the grease
(FP-GS).
6/15
SEIKOH GIKEN Co., Ltd.

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA Product data subject to change
without notice.
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine
SFP-550 Maintenance Manual
Figure 1-2-2: Dimension check for the turntable and others
We provide the height gauge(P/N: FP-HG55) for this inspection as the optional tool.
Reference
− Place the 5.5mm-block gauge and the height gauge on the level block and set the
dial of the height gauge as the hand comes to zero.
Measurement
− Place the gauge on the clamping postsdiagonally and check each four posts. Make
sure that the space on each points is within the specification of 5.50mm•
•0.02mm.
At the scale indication, the specification value is 0(Zero)••2. If the measurement
result is out of this specification at the scale indication, adjust the space in
accordance with the followings.
7/15
SEIKOH GIKEN Co., Ltd.

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA Product data subject to change
without notice.
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine
SFP-550 Maintenance Manual
Adjustment
Adjust the space between the clamping postsand the turntable, if it is out of the
specification value, in accordance with the following procedure.
Loosen the set screws on the side of the base plate (two screws for each clamping
post).
−
−
−
−
Remove the clamping post (pressurizing) unit and spacer.
Measure the thickness of the spacer, t.
Calculate the required thickness of the spacer, with the former measurement result
of the spacer, t, in accordance with the following expression.
Required thickness of the spacer ••Space between the turntable and
clamping post + the thickness of the present spacer, t
Example:
Space between the turntable and clamping post: 4-scale to minus (-0.04mm)
and the thickness of the present spacer, t: 3.00mm, then
Required thickness of the spacer = (-0.04mm) + 3.00mm = 2.96mm
Repeat this procedure for all four clamping postseach.
When you order the spacer (RP55-16), please designate the thickness of the
spacer.
−
8/15
SEIKOH GIKEN Co., Ltd.

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA Product data subject to change
without notice.
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine
SFP-550 Maintenance Manual
Figure 1-2-3: Pressurizing unit check
Loosen the retaining screws on the side of the clamping posts(2 screws for each
post) and remove the pressure adjustment bolt.
−
− Remove the pressurizing coil springs and measure its free length.
Specification for the free length of the coil spring: 14•
•1mm
If the free length of the pressurizing coil spring (RP55-20) is out of the specification,
exchange it for new one.
−
−
−
When you tighten the pressure adjustment bolt, adjust the length betweenthe bolt
head and the upper plane of the clamping post as 5••0.2mm (see the right figure
above).
When you tighten the pressure adjustment bolts, tighten both boltsevenly from the
both side of the clamping post. If the boltsare tightened unevenly,the clamping
levers do not move smoothly.
9/15
SEIKOH GIKEN Co., Ltd.

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA Product data subject to change
without notice.
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine
SFP-550 Maintenance Manual
§§••Treatment for unusual conditions
••••••••••CAUTION••••••••••
Make sure the power cable is unplugged while the inspection and the maintenance.
•
•-••Unusual sound is occurred while the machine is driving.
••Check wear-outs in the drive unit.
2-1-1 Eccentric plates checking
The turntable and the position plate can be removed as they are lifted up.
Make sure that no large scratch or wear-out on the three eccentric plates.−
−
−
Make sure that no large scratch, bend, distortion, or wear-out on the upper side of
the supporting ring.
If there is any large scratch or wear-out on the eccentric plate (RP-55-05) and the
supporting ring (RP55-03), exchange them for new ones. ••••••••••••••••••••••••••••••••
10/15
SEIKOH GIKEN Co., Ltd.

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA Product data subject to change
without notice.
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine
SFP-550 Maintenance Manual
•
•-••The turntable doesn’t move smoothlywhile the machine is
driving. •
•Check wear-outs in the drive unit.
2-2-1 Gear unit checking
The gear unit can be removed as it is lifted up by the center hole of the 100T gear or
the eccentric plates, after the supporting ring is removed.
Make sure that no large scratch, bend, distortion, or wear-out on the bottom side of
a supporting ring.
−
−
−
Make sure that no large scratch, bend, or distortion on the upper and bottom side of
the 100T gear.
Make sure that the bearings attached to the bottom of the turntable moves
smoothly.
11/15
SEIKOH GIKEN Co., Ltd.

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA Product data subject to change
without notice.
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine
SFP-550 Maintenance Manual
••
2-2-2 Eccentric plates removal
Check the bearings when the eccentric plates do not rotate smoothly. Remove the
eccentric plates from the 100T gear. The eccentric plates are attached by C-rings on the
bottom side of the 100T gear. To take off the c-rings, use the tool generally on the
market.
Make sure that inner hole of bearings for the eccentric plates rotate smoothly.−
The bearingsneed to be replaced when the bearings under the turntable and in the 100T
gear donot move smoothly.Tools, such as a bearing puller and a press are needed to
replace the bearings. Please ask us or our agents if there is any difficulty on the bearing
replacement.
12/15
SEIKOH GIKEN Co., Ltd.

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA Product data subject to change
without notice.
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine
SFP-550 Maintenance Manual
§§••Mechanical Structure
3-1 Mechanical components
## PPaarrtt NNoo.. DDeessccrriippttiioonn QQ''ttyy//sseett
5-Inch turntable for SFP-550 1
1 RP55-01 Bearing for turntable 3
3 RP55-03 Support ring for SFP-550/520 1
4 RP55-04 Position plate for SFP-550/520 1
5 RP55-05 Eccentric drive ring for SFP-550/520
(including knock pin)
3
100T Gear for SFP-550/520 1
6 RP55-06 Bearing for 100T gear 3
8 RP55-08 28T Gear for SFP-550/520 1
9 RP55-09 Retaining collar for SFP-550/520 2
10 RP55-10 C-ring for SFP-550/520/510 3
11 RP55-11 14T Gear for SFP-550/520 1
12 RP55-12 6W Motor & Gear box for SFP-550/520/510
(including "M4-L65"bolt 4pcs)
1
13 RP55-13 20T Gear for SFP-550/520 1
14 RP55-14 15W Motor & Gear box for SFP-550/520
(including "M5-L50"bolt 4pcs)
1
15 RP55-15 Supporting Cclumn for SFP-550/520 8
16 RP55-16 Adjustment spacer 4
17 RP55-17 Clamp rod 4
18 RP55-18 Clamp pin
(including knock pin)
4
19 RP55-19 Clamp lever for SFP-550 4
20 RP55-20 Coil spring for SFP-550 4
21 RP55-21 Cable support rod A 1
22 RP55-22 Strut clamp 1
23 RP55-23 Cable support rod B 1
24 RP55-24 Cable hook 1
25 RP55-25 Cooling fan for SFP-550
(including electrical cord , fan guard)
1
26 RP55-26 Power switch for SFP-550 1
27 RP55-27 Timer switch for SFP-550 1
28 RP55-28 Timer for SFP-550 1
29 RP55-29 Locate pin for SFP-550/520 1
30 RP55-30 Power cord for SFP-550/520 1
31 RP55-31 M6-L75 Allen hex socket screw 4
13/15
SEIKOH GIKEN Co., Ltd.

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA Product data subject to change
without notice.
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine
SFP-550 Maintenance Manual
32 RP55-32 M5-L15 Allen hex socket screw 8
33 RP55-33 M5-L10 Allen hex socket screw 8
34 RP55-34 M4-L15 Allen hex socket screw 4
35 RP55-35 M3-L8 Allen hex socket screw 4
36 RP55-36 M4-L10 Cross recessed head screw 4
37 RP55-37 M3-L8 Cross recessed head screw 9
38 RP55-38 M8-L8 Clamping screw (ball type) 4
39 RP55-39 M5-L5 Set screw 14
40 RP55-40 M4 Nut 3
41 RP55-41 M3 Nut 3
42 RP55-42 M4 Washer 15
43 RP55-43 M3 Washer 3
14/15
SEIKOH GIKEN Co., Ltd.

Contact the professionals at Fiber Optic Center for a quote or to get more details.
focenter.com • 508-992-6464 | (800) 473-4237 • sales@focenter.com
23 Centre Street • New Bedford, MA 02740 USA Product data subject to change
without notice.
Click here for more details on the Seikoh Giken SFP-550C Series High Duty Cycle Production Polishing Machine
SFP-550 Maintenance Manual
3-2 Structure Schematic
15/15
SEIKOH GIKEN Co., Ltd.
Other manuals for SFP-550
1
Table of contents
Other seikoh giken Industrial Equipment manuals
Popular Industrial Equipment manuals by other brands

Water Maze
Water Maze HBG-15 Operator's manual

schmersal
schmersal AZM201Z-CC-T-1P2PW-DU Instructions for operation

Forstreich Maschinenbau
Forstreich Maschinenbau Spiral Cone SK50 Original operating instructions

ABB
ABB CAL18-11 operating instructions

MKS
MKS Newport HXP1000-MECA user manual

Big Dipper
Big Dipper 51000 Series Installation & operation instructions