Seneca S312A-4-L-4R User manual

ENGLISH - 1/21
MI00250 -E3
S312A-4-L-4R / S312A-4-H-4R Line
Advanced Analog Indicators
4-Digits Display with 4 relay outputs
Universal input: voltage, current, thermocouples,, thermoresistors (2, 3 or 4 wires
measurements),potentiometer.
Programmable retransmission of the measured instantaneous value by the isolated
analogoutput(voltageoractive/passivecurrent).
Filterprogrammableat20levelstostabilisereading.
TemperaturemeasurementdisplayableinCelsiusorFahrenheitdegrees.
Coldjunctioncompensationincaseofthermocoupleinput.
4Digitsdisplay.
Four alarms are activable on the instantaneous input value (alarm type: maximum,
minimum,automaticallyresettableornot).
Alarmsstatusvisiblethroughfourledsonthefrontalpanel.
Rs485serialcommunicationwithMODBUSRTUprotocol,maximum32nodes.
Fourrelayoutputsforalarmssignalling.
EasynavigationontheprogrammingMenubythreebuttonsonthefrontalpanel.
QuickconfigurationofthealarmthresholdsbytheQuickAlarmsMenu.
DisturbanceRejectionat50and60Hz.
Displaycontrastsettable.
Fourrelayoutput:defaultstateforout3andout4aresettablebyinternaljumper
1. GENERAL SPECIFICATIONS
2. TECHNICAL SPECIFICATIONS
Potentiometer Input:
Analog Output:
Thermocouple Input:
ThermoresistorInput
(RTD)PT100
Current Input:
Voltage Input:
Power Supply:
ExcitationCurrent:1,1mA.
Potentiometervaluefrom1k to100k tousealwayswitha
parallelresistorequalto330 .
GeneratedCurrent:0..20mA,maxloadresistance:500 .
Voltage:0..10V,minloadresistance:1k
ConfigurableStartandFullscalevalues.
Resolution:2 A/1mV.
Type: J, K, R, S, T, B, E, N; resolution: 10 V Refer to the
TABLE:TCRANGEforthemeasurementrange.
2, 3 or 4 wires measurement, excitation current: 1,1 mA,
resolution:0,1°C.
TemperatureRange:-150°C..650°C.
ResistanceRange:20..350 .
0..20mA,inputimpedance 20
Resolution:10000points.
0..10V,inputimpedance:100k
Resolution:10000points.
CodeS312A-4-L-4R:10-40Vdc,19-28Vca50-60Hz,max3W.
CodeS312A-4-H-4R:85-265Vac50-60Hz,max3W.
EN

Environmental Conditions:
Errors referred to max
measuring range:
Voltage/Current Input:
Input for thermocouples:
J,K,E,T,N:
Input for Thermocouples:
R,S:
Input for Thermocouples:
B :
Cold junction compens.:
Potentiometer :
Thermoresistor Input :
Voltage/Current Output :
Isolation :
Connections :
Protection Degree :
Dimensions (L x W x H)
Standards
Temperature: -10..60°C, Humidity min: 30%, max 90% at
40°Cnon-condensing.
Calibration
Error Thermal
Coefficient Linearity
error Others
0,1% 0,01%/°K 0,05% EMI :<1%(2)
0,1% 0,01%/°K 0,5 °C EMI :<1%(2)
0,1% 0,01%/°K 1 °C EMI :<1%(2)
0,1% 0,01%/°K 2 °C EMI :<1%(2)
" 1,5 °C
0,1% 0,01%/°K 0,1% EMI :<1%(2)
0,1% 0,01%/°K 0,2% EMI :<1%(2)
EMI :<1%(2)
0,1% 0,01%/°K 0,05%
1500Vamongeachpairofports
-Removablescrewterminals,pitch3,5mm/5,08mm.
-Threebuttonsformenunavagation.
IP65 (on the frontal panel with the provided seal)
98,2 x 88,5 x 48 mm
EN61000-6-4/2002-10 (electromagnetic emission, industrial
environment).
EN61000-6-2/2006-10 (electromagnetic immunity, industrial
environment).
EN61010-1/2001(safety).
All circuits must be isolated from the other circuits under
dangerous voltage with double . The power supplyisolation
transformer must comply with EN60742: “Isolated
transformersandsafetytransformers”.
(2) EMI: electromagnetic interferences.
Sampling Frequency: Fixed:2Hz.
Response Time: 700ms.
Relay output: Capacity:5A/250Vac.
Table: TC Range
Admitted
Range Admitted
Range
TC
TYPE
TC
TYPE S
-210..1200 °C -50..1768 °CJR
-200..1372 °C -50..1768 °C
KB
-200..1000 °C 250..1820 °C(3)
ET
-200..1300 °C -200..400 °C
N
(3) Up to 250 °C, the output is considered equivalent to a null temperature.
ENGLISH - 2/21MI00250 -E3

NC
NO
NC
NO
4. FUNCTIONING DESCRIPTION
Themeasuredorintegratedinputvalueistranslatedintoananalogoutputsignal.
The instantaneous measurement of the input is displayed. The values are also available via
ModbusRTUprotocoluponquerybyRS485bus.
4.3 Alarms on the Analog input
Four alarms may be activated on the instantaneous value of the input. Each alarm may be set
onthefollowingway:
1)Alarmontheminimumthershold. 2)Alarmonthemaximumthershold.
3)Retained Alarmontheminimumthreshold(theresetisnotautomatic).
4)RetainedAlarmonthemaximumthreshold(theresetisnotautomatic).
For each alarm, it is possible to set Threshold and Hysteresys. If the alarm is set as high, the
alarmwillturnOFFwhentheinputvalueisThreshold-Hysteresys;insteadifthe alarmissetas
low, the alarm condition will end when if the input value is Threshold+Hysteresys.The alarms
status is displayed by four leds on the frontal panel and by the relays. The relays toggle at the
alarmconditionandreturntotheinitialstatusattheend ofthealarmconditionoratthereset(if
retained). The retained alarms are reset by pressing the buttons + for someUP OK/MENÙ
seconds(onnormalviewfunctioning).
4.2 Retransmission Modalities
Theinstrumentallowsthefollowingretransmissionmodalities:
Analog Output: The measured input value is translated into an analog outputsignal (voltage
orcurrent).
4.1 Setting Modalities
All the parameters of the instrument may be set by the programming Menu or RS485. The
alarms thresholds may be quickly set by the . Besides the software hasQuick Alarm Menu
beendevelopedfortheprogrammingandtheconfigurationofthemodule(consultthewebsite
www.seneca.it).
ENGLISH - 3/21MI00250 -E3
3. RELAYS AND JUMPER
POSITION
ToextracttheboardsfromS312Abox:
1) remove the screw terminals from
rearpanel
2) press inwards the box on the top
panel (where there is the serigraphy)
and, at the same time, press inwards
theboxonthebottompanel
3)extractthedisplayindicator
4)extracttheboardsfrombox.
Boardsareasinthefollowingfigure.
*NOTE: DEFAULT: N.O. means
«NORMALLYOPEN»
JUMPER
( )DEFAULT:N.O.
JUMPER
( )DEFAULT:N.O.

mA input
+
The loop is powered
by the module (17 V Loop)
CURRENT INPUT mA input (2 wires) VOLTAGE INPUT
3.0 W
10 ÷ 40 VDC
19 ÷ 28 VAC
1
2A
POWERSUPPLY:Verifythecodeontheappliedlabel.
99
10 10
8
7
+
8
7
9
10
8
7
6.ELECTRICALCONNECTIONS
4.4 Password for access to the menu
Code S312A-4-L-4R
3.0 W
85 ÷ 265 VAC
1
2B
Code S312A-4-H-4R
+
2 wires
9
10
8
7
PT100 INPUT
3 wires 4 wires
9
10
8
7
9
10
8
7
THERMOCOUPLE INPUT
+
Resistance R=330 (not provided),
P=1 k 100 k
POTENTIOMETER INPUT
R=330 P
10
9
8
7
9
10
8
7
The loop is powered
by the sensor
ItispossibletoenabletheprotectionoftheProgrammingMenubypassword.
TheQuickAlarmMenuisinsteadpasswordfree.
ENGLISH - 4/21MI00250 -E3
Rs485
Led
22 22 223 1
Alarm 3/1
Led
Alarm 4/2
1987
1 2A2B 6543 10
DOWN OK/MENÙUP
Relay
1
4
21
11
08
971 11 11 16 35 24 1
F : B LRONTAL PANEL UTTONS AND EDS
REAR SIDE: TERMINALS
Pow. Supply Output Input
5.BUTTONSANDTERMINALSPOSITION Relay
2
Relay
3
Relay
4
3

11
12
13 16
RS485 Relay Output 1 (5 A/250 Vac) Relay Output 2 (5 A/250 Vac)
N.C. N.C.
N.O. N.O.
Com. Com. 15
14
Voltage
+
ANALOG OUTPUT
Generated Current Ext. Power Supply Current
+
5
4 4
4
3 3
1 = Voltage
2 = Current
3 = Potentiometer
Input Type 2 :
Current
Default
Value
Description and setting rangeParameter NameParameter
Symbol
Parameters settable from Menu :
21
22
23
B
A
GND
7. MENU’S PARAMETERS
Parameter
Symbol Parameter Name Description and setting range Default
Value
Enables the
Password for the
access to menu
Setting a value diffferent from , the5477
password (always 5477) will be required at the
startofthemenu.
5477:
Password
disabled
Parameters settable from Menu :
4 = TC J
5 = TC K
6=TCR
7=TCS
8=TCT
9 = TC B
10=TCE
Active Output
(powered) to
connect to
passive inputs.
Unpowered
passive output to
be connected to
active inputs.
11=TCN
12=PT100(2wires)
13=PT100(3wires)
14=PT100(4wires)
. . . .
. . . .
ENGLISH - 5/21MI00250 -E3
RELAY OUTPUT
17
18
Relay Output 3 (5 A/250 Vac) Relay Output 4 (5 A/250 Vac)
N.O./N.C.
(set the jumper)
Com. Com. 20
19
N.O./N.C.
(set the jumper)
Default: N.O.
normally open Default: N.O.
normally open

Temperature
measurement in
° C or ° F
0=Celsiusdegrees.
1=Fahrenheitdegrees.
0=nofilter
1...20
Filter Level
0 = ° C
0 = No
filter
Onlyforinputtype1,2and3.
Start scale in V (voltage input) or mA (current
input)or%(potentiometer).
It defines also the value of the input signal
associatedtotheminimumvalueofview( ) .
SettableValues
Values included between the minimum and
maximum limits specified for the secleted input
type.MinimumValue:0,MaximumValue:99,99.
Electrical Start
Scale Value 4,00 (mA)
Electrical Full
Scale value Onlyforinputtype1,2and3.
Full scale in V (voltage input) or mA (current
input)or%(potentiometer).
It defines also the value of the input signal
associatedtothemaximumvalueofview( ) .
SettableValues
Values included between the minimum and
maximum limits specified for the secleted input
type.MinimumValue:0,MaximumValue:99,99.
20,00
(mA)
Parameters settable from Menu :
Default
Value
Description and setting rangeParameter NameParameter
Symbol Onlyforinputs1,2and3.
Integervaluesbetweenthefollowinglimits:
Start scale of
instantaneous view 0
Display Digits
Number Min. Limit Max. Limit
49999
-1999
Full scale of
instantaneous view 1000
Inputs1,2and3
0=nodecimalpoint(ex1234),
1=firstdigit(es123.4) ... ...
Ndisplaydigit-1
TemperatureMeasurement
0 = resolution: °C (°F).
1 = resolution: °C/10 (°F/10).
Decimal Point
position on the
instantaneous view
0 = No
decimal
point
. . . .
ENGLISH - 6/21
MI00250 -E3

ENGLISH - 7/21MI00250 -E3
. . . . . . . . . . . . . . . .
49999
-1999
1000
10
10
1000
49999
-1999
1000
10
10
1000
Alarm 1 Threshold
Alarm 1 Hysteresys
Display Digits
Number Min. Limit Max. Limit
Default
Value
Description and setting rangeParameter NameParameter
Symbol
Parameters settable from Menues :
Alarm 4 Threshold
Alarm 2 Hysteresys
0: Al 2
disabled
Value referred to the displayed value (decimal
pointsetby ).
Temperature input: value expressed as set by
(°Cor°F).
Settablevalueonthefollowingranges:
Alarm 1 Type
Alarm 2 Type
0=Alarmdisabled
1=Alarmontheminimumthreshold
2=Alarmonthemaximumthreshold
3 = Retained alarm on the minimum threshold
(theresetisnotautomatic)
4 = Retained alarm on the maximum threshold
(theresetisnotautomatic)
0: Al 4
disabled
RelayFunctioning:
0=relaynormallyopened(N.O.)
1=relaynormallyclosed(N.C.).
Relay 4: N.O./N.C.
Relay 2: N.O./N.C.
0: N.O.
0: N.O.
Alarm1parameters:accessiblefrom . . menuandidentifiedbythefinalindex1.
Alarm2parameters:accessiblefrom . . menuandidentifiedbythefinalindex2.
Alarm3parameters:accessiblefrom . . menuandidentifiedbythefinalindex3.
Alarm4parameters:accessiblefrom . . menuandidentifiedbythefinalindex4.
Alarm 3 Threshold
Alarm 3 Hysteresys
Alarm 2 Threshold
Value referred to the displayed value (decimal
pointsetby ).
Temperature input: value expressed as set by
(°Cor°F).
Settablevalueonthefollowingranges:
Display Digits
Number Min. Limit Max. Limit
0: Al 1
disabled
0: Al 3
disabled
0: N.O.
0: N.O.
Relay 1: N.O./N.C.
Relay 3: N.O./N.C.
Alarm 3 Type
Alarm 3 Threshold
Alarm 4 Hysteresys
Alarm 4 Type
0=Alarmdisabled
1=Alarmontheminimumthreshold
2=Alarmonthemaximumthreshold
3 = Retained alarm on the minimum threshold
(theresetisnotautomatic)
4 = Retained alarm on the maximum threshold
(theresetisnotautomatic)
RelayFunctioning:
0=relaynormallyopened(N.O.)
1=relaynormallyclosed(N.C.).

MODBUS Address
Parameter NameParameter
Symbol
Parameters settable from Menu :
Serial
communication
speed
Parity control
Delay of the
response
1
Default
Value
Description and setting range
0: No
Delay
SettableValues:from1to255.
0=4800
1=9600
2=19200
0=None 1=Even 2=Odd. 0: None
Number of pauses of 6 characters each to be
entered between the end of the Rx message
andthestartoftheTx.Settablevalue: 0..255.
3=38400
4=57600
5=115200
6=1200
7=2400
8=14400
Serialcommunicationspeedinbaud: 3: 38400
Parameters settable from Menu :
Display Contrast
Parameter Name
Parameter
Symbol 10
Default
Value
Description and setting range
Values:1(minimumcontrast) to20(maximum).
Behavior in case of
Burn out (with
PT100 or TC)
0=Fullscalevalueindication
1=Startscalevalueindication
If the value is set to full scale, also the
retransmittedoutputgoestothe100%(0%ifthe
value is set to the start scale) and the maximum
(minimum)alarmsareactivated.
0: Full
scale
Indicat.
1 = Overwrite the set values with the default
values.
Default Settings
By confirming with all the parametes are saved inOK/MENÙ
flashmemoryandaftersomeinstantsthemoduleisreset.
. . . .
. . . .
. . . .
Instantaneous
display value
associated to the
minimum value of
the output.
Parameter NameParameter
Symbol
Parameters settable from Menu :
Retransmitted
output type
Instantaneous
display value
associated to the
maximum value of
the output.
Display Digits
Number
49999
Min. Limit Max. Limit
-1999
0
Default
Value
Description and setting range
1000
Limits for the scaling of the retransmitted
output. Decimalpointsetby .
Settablevaluesonthefollowinglimits:
1= 0..10V 2:
4..20 mA
2=4..20mA
3=0..20mA
. . . .
ENGLISH - 8/21MI00250 -E3

The indicators have MODBUS 16 bits (words)S312A-4-L-4R and S312A-4-H-4R lines
registers, accessiblebyRS485serial communication.
10.1 Supported MODBUS Commands
Code
03
06
16
Function
Read Holding Registers
Write Single Register
Write Multiple Registers
Description
Reading of word registers up to at a time.16
Writing of a word register.
Writing of word registers up to 6 at a time.1
: communication error with the cold junction thermometer.
: at the start may signal an error on the calibration memory. The functioning of the
moduleisblockedwhiletheModbuscommunicationisavailable.
: Instantaneous value to display < value of the 2.5% or instantaneous value to
display<minimumdisplayable.
: Instantaneousvaluetodisplay> valueofthe2.5%oriftheinstantaneousvalue>
maximumdisplayable.
The errors are directly viewed through display.
Wearegoingtolistallthepossiblesignallingswiththecorrespondentmeaning:
8. ERROR SIGNALLINGS
10. MODBUS REGISTERS
: Burn-out of the temperature sensor.
9. ORDER CODES
Code
Model
Display
Power Supply
Output relay
Description
S312A Indicator with universal analog input, 4 relays.
-4 4 digits
85..265 VAC
10..40 V / 19..28 VDC AC
4outputrelay
-H
-L -4R
ENGLISH - 9/21MI00250 -E3
Options CalibrationandconfigurationService
/T

InthetablethenotationBit[x:y] indicatesallbitsfromx toy.ForexampleBit[2:1]indicates
bit 2 and bit 1, and serves to illustrate the meaning of the various united combinations of
thevaluesofthetwobits.Defaultvaluesareindicatedwiththe*symbol.
Set the input type:
1 : Voltage, 2* : Current
3:Potentiometer,4:ThermocoupleJ
5:ThermocoupleK,6:ThermocoupleR
7:ThermocoupleS,8:ThermocoupleT
9:ThermocoupleB,10:ThermocoupleE
11:ThermocoupleN,12:PT100(2wires)
13:PT100(3wires),14:PT100(4wires)
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Most significant Bit Least significant bit
Bit Index
Word (16 bits): MODBUS Register
TemperatureinCelsiusorFahrenheitdegrees:
0*:Celsius 1:Fahrenheit
The 16-bit Holding Registers have the following structure:
10.2 Holding Registers
Description ADDR R/W
Bit [15:8]: contain the module's ID: 70.
Bit[7:0]:containthefirmware'srevision.
Register containing the internal code of the
firmware.
Registerfor the setting of the input type and of
thetemperaturemeasureunit. 40003
40002
40001 R
R
R/W
REGISTER
MACHINE ID
FW_CODE
TYP_INP_CEL_FAHR
Bit [15:8]
Bit [7:1] Notused
Bit 0
HI_E Electrical Full Scale of the input in V/100,
mA/100or%/100 R/W40004
Bit [15:0] FullscaleinVolt/100,mA/100or%/100respectively
for input types 1, 2 and 3. This value must be
included between the minimum and maximum
specified for each input. Besides this parameter
defines the value of the input signal associated to
the maximum instantaneous value of view: HI_D.
Min:0, Max:9999.Default:2000.
LO_E Electrical Start Scale of the input in V/100,
mA/100or%/100 R/W
40005
Start scale in Volt/100, mA/100 or %/100
respectively for input types 1, 2 and 3. This value
must be included between the minimum and
maximum specified for each input. Besides this
parameter defines the value of the input signal
associated to the minimum instantaneous value of
view: LO_D. Min:0, Max:9999.Default:400.
Bit [15:0]
ENGLISH - 10/21
MI00250 -E3

Setthefilterlevel.
Admittedvalues:0*=nofilter,1..20.
DP/FILTER Decimalpointposition. R/W40006
Decimalpointposition:
0*=decimalpointabsent(ex.1234),
1 = first digit (ex 123.4), 2 = second digit, ....., N
displaydigits-1.
Fortemperaturemeasurements:
0:°C(°F)resolution,1:°C/10(°F/10)resolution.
Bit [15:8]
Bit [7:0]
ENGLISH - 11/21MI00250 E3-
TYP_AL1/RLY1
Bit [15:8]
Bit [7:1]
R/W40007
TYP_AL2/RLY2 R/W40008
Bit 0
Bit [15:8]
Bit [7:1]
Bit 0
SettheAlarm1functioning:
0*=Alarmdisabled
1=Alarmontheminimumthreshold
2=Alarmonthemaximumthreshold
3=Retainedalarmontheminimumthreshold(reset
isnotautomatic)
4 = Retained alarm on the maximum threshold
(resetisnotautomatic)
Sets the normal status of relay 1 and alarm 1
type.
Notused
Setstherelay2functioning:
0*=normallyopened
1=normallyclosed
Sets the normal status of relay 2 and alarm 2
type.
SettheAlarm2functioning:
0*=Alarmdisabled
1=Alarmontheminimumthreshold
2=Alarmonthemaximumthreshold
3=Retainedalarmontheminimumthreshold(reset
isnotautomatic)
4 = Retained alarm on the maximum threshold
(resetisnotautomatic)
Notused
Setstherelay1functioning:
0*=normallyopened
1=normallyclosed

ENGLISH - 12/21
MI00250 -E3
TYP_AL3/RLY3
Bit [15:8]
Bit [7:1]
R/W40009
TYP_AL4/RLY4 R/W40010
Bit 0
Bit [15:8]
Bit [7:1]
Bit 0
SettheAlarm3functioning:
0*=Alarmdisabled
1=Alarmontheminimumthreshold
2=Alarmonthemaximumthreshold
3=Retainedalarmontheminimumthreshold(reset
isnotautomatic)
4 = Retained alarm on the maximum threshold
(resetisnotautomatic)
Sets the normal status of relay 3 and alarm 3
type.
Notused
Setstherelay4functioning:
0*=normallyopened
1=normallyclosed
Sets the normal status of relay 4 and alarm 4
type.
SettheAlarm4functioning:
0*=Alarmdisabled
1=Alarmontheminimumthreshold
2=Alarmonthemaximumthreshold
3=Retainedalarmontheminimumthreshold(reset
isnotautomatic)
4 = Retained alarm on the maximum threshold
(resetisnotautomatic)
Notused
Setstherelay3functioning:
0*=normallyopened
1=normallyclosed
PASSWORD Enables / disables the password for the
accesstotheprogrammingmenu. R/W40011
Bit [15:0] By setting a value different from , at the start of5477
the programming menu the password (always
5477)willberequired.Default:5477.
TYP_OUT/BURN Sets the behavior in case of Burn Out (PT100
orTC)andoutputtype R/W40012
Settheretransmittedoutputtype:
1=0..10Voutput
2*=4..20mAoutput
3=0..20mAoutput
Bit [15:8]
Bit 0 Behavior in case of PT100 or Thermocouple Burn
out:
0*=Fullscaleindication
1=Startscaleindication.
Bit [7:1] Notused

ENGLISH - 13/21MI00250 -E3
Bit [7:0]
Set the display contrast: values from 1 (minimum
constrast)to20(maximumcontrast).Default:10.
CONTRAST Displaycontrast R/W40013
Bit [15:8]
Notused
SET2
HYS2
Alarm2Threshold
Alarm2Hysteresis
R/W
R/W
40016
40017
Bit [15:0]
Bit [15:0]
Alarm 2 threshold: value referred to the view scale
but without decimal point. For example if the value
referredtotheviewscaleis20,0sets200.SeeHI_T
forparameterlimits.
Default:1000.
Alarm 2 hysteresis: value referred to the view scale
but without decimal point. For example if the value
referred to the view scale is 10,00 sets 1000. See
HI_Tforparameterlimits.
Default:10.
SET1
HYS1
Alarm1Threshold
Alarm1Hysteresis
R/W
R/W
40014
40015
Bit [15:0]
Bit [15:0]
Alarm 1 threshold: value referred to the view scale
but without decimal point. For example if the value
referredtotheviewscaleis20,0sets200.SeeHI_T
forparameterlimits.
Default:1000.
Alarm 1 hysteresis: value referred to the view scale
but without decimal point. For example if the value
referred to the view scale is 10,00 sets 1000. See
HI_Tforparameterlimits.
Default:10.
SET3
HYS3
Alarm3Threshold
Alarm3Hysteresis
R/W
R/W
40018
40019
Bit [15:0]
Bit [15:0]
Alarm 3 threshold: value referred to the view scale
but without decimal point. For example if the value
referredtotheviewscaleis20,0sets200.SeeHI_T
forparameterlimits.
Default:1000.
Alarm 3 hysteresis: value referred to the view scale
but without decimal point. For example if the value
referred to the view scale is 10,00 sets 1000. See
HI_Tforparameterlimits.
Default:10.

ENGLISH - 14/21MI00250 -E3
SET4
HYS4
Alarm4Threshold
Alarm4Hysteresis
R/W
R/W
40020
40021
Bit [15:0]
Bit [15:0]
Alarm 4 threshold: value referred to the view scale
but without decimal point. For example if the value
referredtotheviewscaleis20,0sets200.SeeHI_T
forparameterlimits.
Default:1000.
Alarm 4 hysteresis: value referred to the view scale
but without decimal point. For example if the value
referred to the view scale is 10,00 sets 1000. See
HI_Tforparameterlimits.
Default:10.
HI_T Displayed value correspondent to the
maximumvalueoftheanalogoutput R/W40022
Bit [15:0] Displayed input value corresponding to
retransmitted output maximum value. Set the value
referred to the view scale but without decimal point.
Example: if the value referred to the view scale is
10,0,set100.Default:1000.
Minvalue:-1999 Maxvalue:9999
LO_T Displayed value correspondent to the
minimumvalueoftheanalogoutput R/W40023
Bit [15:0]
LO_D StartScalevalueofinstantenousview R/W40025
Bit [15:0]
HI_D FullScalevalueofinstantenousview R/W40024
Bit [15:0] Set the full scale value of the view scale. Only for
input1,2and3.Thedecimalpointonthesetinteger
value is given by . Default: 1000. Min and maxdP
values:see .HI_T
Set the start scale value of the view scale. Only for
input1,2and3.Thedecimalpointonthesetinteger
value is given by . Default: 0. Limits value:seedP
HI_T.
Displayed input value corresponding to
retransmitted output minimum value. Set the value
referred to the view scale but without decimal point.
Example: if the value referred to the view scale is
10,0, set 100. Default: 0. Min. and Max value: see
HI_T

ENGLISH - 15/21MI00250 -E3
Cold junction voltage in mV (Floating point
format,mostsignificantword).
Cold junction voltage in mV (Floating point
format,leastsignificantword).
mV_CJ_FLOAT_MSW
mV_CJ_FLOAT_LSW
R
R
40072
40073
Bit 1 1:Faultoncoldjunctionthermometer.
-Bywriting0xC1A0,themoduleisreset.
Bit [15:0] Module’s Reset
RESET R/W40058
STATUS ErrorsandalarmsSignalling. R40059
Bit [15:11] Notused.
Bit 8 1:Alarm 2 active.
Bit 7 1:Alarm 1 active.
Bit 6 1: if the value to view is of the or< 2,5 %
temperaturesensorunderrange.
Bit 5 1 2,5 %: If the value to view is > of the or the
temperaturesensorisoverrange.
Bit 4 1:Temperature Sensor Burn-out
Bit 3 Not used
Bit 2 1: Failure on the cold junction thermometer
initialization.
Bit [15:8]
BAUDR Register for the setting of the Baudrate and
theresponsedelaytimeincharacters. R/W40027
00000000(0x00):4800
00000001(0x01):9600
00000010(0x02):19200
00000011*(0x03):38400
Response delay time. It represents the number of
pauses of 6 characters each to be entered between
the end of the Rx message and the start of the Tx
message.Defaultvalue:0.
Bit [7:0]
Bit 0
Displayedvalue
1:CalibrationEepromdamaged
ContactSenecasrltosolvetheproblem.
DISPLAY R
40064
00000100(0x04): 57600
00000101(0x05):115200
00000110(0x06): 1200
00000111(0x07): 2400
00001000(0x08): 14400
Set the control parity type:
00000000 *: No parity (NONE)
00000001 : Even parity (EVEN)
00000010 : Odd parity (ODD)
Bit [7:0]
Set the module's address. Permissible values from
0x01 OxFFto (decimal values in the range of 1-
255).Default:1.
Bit [15:8]
Registerfor the setting ofthe Modbus address
andparitycontrol.
ADDR R/W
40026
Measure in % if input is potentiometer (Floating
pointformat,mostsignificantword).
Measure in % if input is potentiometer (Floating
pointformat,leastsignificantword).
FLOAT_REAL_MSW
FLOAT_REAL_LSW
R
R
40060
40061
Bit 9 1:Alarm 3 active.
Bit 10 1:Alarm 4 active.

ENGLISH - 16/21MI00250 -E3
TEMP_TC_FL_MSW
TEMP_TC_FL_LSW
TEMP_CJ_SHORT
Rx_FLOAT_MSW
Rx_FLOAT_LSW
TEMP_RTD_FL_MSW
TEMP_RTD_FL_LSW
Rx_short
R
R
R
R
R
R
R
R
R
R
R
R
40076
40077
40078
40079
40080
40081
40082
40083
40085
40087
40084
40086
mVOLT_FL_MSW
AMPER_FL_MSW
mVOLT_FL_LSW
AMPER_FL_LSW
mV_TC_FL_MSW
mV_TC_FL_LSW
R
R
40074
40075
Temperature in °C read from the thermocouple
(Floatingpoint,mostsignificantword).
Temperature in °C read from the thermocouple
(Floatingpoint,leastsignificantword).
Coldjunctiontemperaturein1/256of°C.
Resistance in Ohm if PT100 (Floating point
format,mostsignificantWord).
Resistance in Ohm if PT100 (Floating point
format,leastsignificantWord).
Temperature read from PT100 in °C (Floating
pointformat,mostsignificantword).
Temperature read from PT100 in °C (Floating
pointformat,leastsignificantword).
MeasuredresistanceifPT100(in )/100
Measurement in mV in case of voltage input
(Floatingpointformat,mostsignificantword).
Measurement in mV in case of voltage input
(Floatingpointformat,leastsignificantword).
Measurement in A in case of current input
(Floatingpointformat,mostsignificantword).
Measurement in A in case of current input
(Floatingpointformat,leastsignificantword).
SENECA s.r.l.
Via Austria, 26 - 35127 - PADOVA - ITALY
Tel. +39.049.8705355 - 8705359 - Fax +39.049.8706287
e-mail: info@seneca.it - www.seneca.it
THE INTERNATIONAL CERTIFICATION NETWORK
R
ISO9001-2000
Thisdocumentisproperty ofSENECAsrl.Duplicationandreprodutionareforbidden,ifnotauthorized.Contents
ofthepresentdocumentationreferstoproductsandtechnologiesdescribedinit.Alltechnicaldatacontainedinthe
documentmaybemodifiedwithoutpriornoticeContentofthisdocumentationissubjecttoperiodicalrevision.
DisposalofElectrical&ElectronicEquipment(ApplicablethroughouttheEuropeanUnionand
otherEuropeancountrieswithseparatecollectionprograms)
This symbol, found on your product or on its packaging, indicates that this product should not be
treated as household waste when you wish to dispose of it. Instead, it should be handed over to an
applicable collection point for the recycling of electrical and electronic equipment. By ensuring this
product is disposed of correctly, you will help prevent potential negative consequences to the
environment and human health, which could otherwise be caused by inappropriate disposal of this
product. The recycling of materials will help to conserve natural resources. For more detailed
information about the recycling of this product, please contact your local city office, waste disposal
serviceorthèretailstorewhereyoupurchasedthisproduct.
Voltage in mV read from the thermocouple
(Floatingpoint,mostsignificantword).
Voltage in mV read from the thermocouple
(Floatingpoint,leastsignificantword).

MI002502-E
11
11.1
11.2
11.3

MI002502-E
11.7
11.4
11.5
11.6
DEFAULT SETTING
SYSTEM

MI002502-E

MI002502-E
This manual suits for next models
1
Table of contents
Other Seneca Touch Panel manuals