TECHNICAL SPECIFICATIONS
STANDARDS
EN61000-6-4 Electromagnetic emissions, industrial environment.
EN61000-6-2 Electromagnetic immunity, industrial environment.
EN61010-1 Safety.
INSULATION Using an insulated conductor, its sheath determines the insulation voltage. An insulation of 3
kV ac is guaranteed on bare conductors
ENVIRONMENTAL
CONDITIONS
Temperature: -20 – + 70°C
Humidity: 10%– 90% non condensing.
Altitude: Up to 2000 m above sea level
Storage temperature: -40 – + 85°C
Degree of protection: IP20.
ASSEMBLY 35mm DIN rail IEC EN60715
CONNECTIONS Removable 5-way screw terminals, 5 mm pitch for cable up to 2.5 mm2
micro USB
POWER SUPPLY Voltage: on Vcc and GND terminals, 11.5 – 28 Vdc;
Absorption: Typical: 21 mA (LOAD EXCLUDED)
COMMUNICATION
PORT
RS485 serial port on terminals A+ and B-; or on USB port
INPUT
(on 20.8 mm
through hole)
Type of measurement: AC/DC TRMS or DC Bipolar
Crest factor: 2
Pass-band: 1 kHz
Overload: 2000 A impulsive, 3 x INcontinuing
CAPACITY AC/DC True RMS (DIP7=OFF) DC Bipolar (DIP7=ON)
T201DCH50-MU 0 – 25A or 0 - 50A -0 – +25A or -50 - +50A
T201DCH100-MU 0 – 50A or 0 - 100A -50 – +50A or -100 - +100A
T201DCH300-MU 0 – 150A or 0 - 300A -150 – +150A or -300 - +300A
ANALOGUE
OUTPUT
on Vout and
GND terminals
Type: 0 – 10 Vdc, minimum load RLOAD =2 kΩ.
Protection: Reverse polarity protection and over voltage protection
Resolution: 13 bit (10000 points)
EMI error: < 0.5%
Temperature coefcient: < 200 ppm/°C
Hysteresis on measurement: 0.2% of full scale
Response speed: With «Fast» lter 800 ms. With «Slow» lter 2000 ms.
The type of output can be selected via software
DIGITAL
OUTPUT
on Vout and
GND terminals
Type: active, 0 – Vcc, maximum load 50 mA
The type of output can be selected via software
ACCURACY below 2% of full scale above 2% of full scale
T201DCH50-MU
1% of full scale at 50/60 Hz, 23°C 0.5% of full scale at 50/60 Hz, 23°C
T201DCH100-MU
T201DCH300-MU
OVERVOLTAGE
CATEGORIES
Bare conductor: CAT. III 300 V
Insulated conductor: CAT. III 600 V
3/4