Senix ULTRA-30 Series User manual

ULTRA-30 ultrasonic dis-
tance sensors provide an
output between 0 and 10 volts
DC that is proportional to the
distance of a measured target.
The voltage output range can be
calibrated to span the distance
between any two distance "end-
points" in the sensor's range.
The slope can either increase
or decrease with distance. Both
endpoints are push-button
adjustable. It includes a sensitive
transducer and electronics in a
small threaded, rugged, anod-
ized aluminum enclosure that is
easily mounted. Typical applica-
tions measure roll diameters,
and object sizes and height.
• Designed for indoor or dry
environment applications
• Standard 0-10 VDC output
has adjustable distances and
polarity
• Long range, short deadband
• High sensitivity for weak or
non-woven targets
• Simple pushbutton “teach”
setup of many features, and
calibration using actual targets
• Rear LED Status indicator
quickly identifies proper and
improper target conditions
• CE compliant for use in EU
• Output response filter for
stability with unstable targets
• Security “Lock” prevents
accidental mis-adjustment
• All in one small package!
• Simple 3-wire interface–power,
ground and voltage output
• Threaded aluminum
housing quickly bolts into a
round mounting hole
• Permanently attached 2-meter
cable
• Simple push-button TEACH
setup - no potentiometers!
• Rear pushbutton is used with
rear indicator to accomplish all
TEACH features
• Rear indicator displays target
status conditions including too
close, no target and target out
of calibrated range.
• Detects both hard and soft
objects
• Stable outputs and output filter
options
• No light or laser beam required
• Works in the dark
• Works with optically reflective,
transparent or opaque materials
• Unaffected by target color
ULTRA-30-VA
• Dual range, teach selected
• Short: 3-40 in. (76-1000 mm)
• Long: 5-80 in. (127-2030 mm)
ULTRA-30L-VA
• Longest range version
• 6.5-180 in. (165-4572 mm)
Ultrasonic Distance Sensor
Voltage Output and Push-Button "Teachable"
Dimension or Sort Object Detection
Non-Contact
Ultrasonic
Air Distance
Measurement
ULTRA-30 Series
Reliable OperationFeatures Easy Installation
Roll DiameterWeb/Loop Control
Sensitive transducer detects most materials
Push-button
"teach"
Models
Senix Corporation, 52 Maple St., Bristol, VT 05443 U.S.A.
Phone: 800-677-3649 or 802-453-5522 FAX: 802-453-2549
Web Site: http://www.senix.com e-mail: [email protected]
ULTRA-30 Teachable Ultrasonic Distance Sensor
Range - model
ULTRA-30-VA*
Short: 3-40 in. (76-1000 mm)
Long: 5-80 in. (127-2030 mm)
Range - model
ULTRA-30L-VA
6.5-180 in. (165-4572 mm)
Resolution 0.078 in. (2 mm) Adjustments Push-button, permanently stored
Enclosure Anodized aluminum, black Transducer High sensitivity electrostatic
Protection NEMA-1, IP30 Input Power 15-30 VDC @ 30 ma. nominal
Measure Rate 20 per second Humidity 0 to 95% non-condensing
Response Time 50 mSec with response filter off, approx. 4 seconds 10-90% with response filter ON
Beam Pattern 15 degrees total angle (nominal) @ -3db, conical shape
Repeatability Greater of 0.5% of target distance or +/-2mm at constant temperature
Temperature 0 to 70 degrees C (32 to 158 degrees F)
Voltage Output 0 to 10 volts DC, 100-ohm impedance, teachable endpoints, reversable slope
Connections Permanently attached cable, 6 feet (2 meters)
Specifications
Adjustments
Dimensions
Wiring (3-wire cable)
Brown DC+ IN
Blue GND
Black 0-10 VDC
(Output)
Rear Status Indicator
This LED has four functions:
(1) ON continuously when a
stable target is within the adjust-
ed 0-10 VDC span, (2) flashes
slowly for targets out of span but
in sensor's range capability, (3)
flashes quickly when no target
is detected or target is closer
than the minimum range and (4)
flashes slowly during TEACH
setup.
Push-button Switch
Used to set the TEACH features
listed in table. To TEACH, count
the status indicator flashes while
switch is pressed and held.
TEACH
Flashes Sensor Feature Selected
4 Set the 0 VDC distance endpoint (anywhere in range, using a target)
5 Set the 10 VDC distance endpoint (anywhere in range, using a target)
6 Set response time = SLOW (step change approx. 10-90% in 4 seconds)
7 Set response time = FAST (updates every 50 mSec.)
10 Unlock/lock sensor for adjustment. Relocks automatically after 15 min-
utes or power is recycled.
12 ULTRA-30-VA: Set LONG range and all factory defaults
ULTRA-30L-VA: Set factory defaults with 8-in. (203 mm) minimum range
13 ULTRA-30-VA: Set SHORT range and all factory defaults
ULTRA-30L-VA: Set factory defaults with 6.5-in. (165 mm) min range
Note: Adjust a feature by holding TEACH button pressed until the LED flashes the number of times in
the "TEACH Flashes" column, then release it. The sensor must first be unlocked using 10 flashes. It
any TEACH feature is attempted before Unlocking, the rear indicator will display 3 successive short-
long flashes then the sensor resumes operation and all reatures remain unchanged.
This product is not recommended for applications with hazardous or explosive materials, or as a primary device for personal safety.
Copyright 2004, Senix® Corporation. All rights reserved. Printed in U.S.A.
14 Jan 04
Dimensions
Dimensions are in mm
Mounting Hole: 1.2 in. (30.5 mm)
diameter
Standard Cable: 6.5-ft (2 m)

This manual suits for next models

2

Popular Analytical Instrument manuals by other brands

SMART365 SM-06-01041 manual

SMART365

SMART365 SM-06-01041 manual

Leuze electronic ODS 10 operating instructions

Leuze electronic

Leuze electronic ODS 10 operating instructions

CONDTROL SMART 60 user manual

CONDTROL

CONDTROL SMART 60 user manual

Ryobi LDM-32 Owner's operating manual

Ryobi

Ryobi LDM-32 Owner's operating manual

BURG WATCHER QUADRO PS 7350 operating instructions

BURG WATCHER

BURG WATCHER QUADRO PS 7350 operating instructions

geo-FENNEL FVE 100 user manual

geo-FENNEL

geo-FENNEL FVE 100 user manual

Teledyne 3000MA instruction manual

Teledyne

Teledyne 3000MA instruction manual

Depstech WF010 user manual

Depstech

Depstech WF010 user manual

RS Technical Services DD LITE 2 Operation manual

RS Technical Services

RS Technical Services DD LITE 2 Operation manual

Hitachi UG 50Y Handling instructions

Hitachi

Hitachi UG 50Y Handling instructions

Wolfgang LDM01 Operation and Function Manual

Wolfgang

Wolfgang LDM01 Operation and Function Manual

Teledyne TED 200-T instruction manual

Teledyne

Teledyne TED 200-T instruction manual

RIDGID micro CA-350 Operator's manual

RIDGID

RIDGID micro CA-350 Operator's manual

Smith-Root LR-20 Series user guide

Smith-Root

Smith-Root LR-20 Series user guide

Bacharach TLV sniffer instruction manual

Bacharach

Bacharach TLV sniffer instruction manual

AFL FOCIS Duel Quick reference guide

AFL

AFL FOCIS Duel Quick reference guide

SCIEX Anion Analysis Kit Instruction guide

SCIEX

SCIEX Anion Analysis Kit Instruction guide

Olimpus IPLEX RT Operation manual

Olimpus

Olimpus IPLEX RT Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.