1. Press and hold the power button until
the display illuminates. Display will remain
blank for 10-15 seconds during start up
prior to displaying Sensit logo followed by
“Select a depth”.
2. Place measuring device in desired test
area. For best results limit the test length
(scan) to 10ft.
3. Using the A or C button select test
depth. Deep is greater than 10ft. Normal
is up to 10ft.
4. Using the A or C button select a scan
direction. Step to Left or Step to Right.
5. Using the A or C button select a step
distance. 6 or 12 inches. For softer surfaces
and/or shallow depths us 6 inch distances.
6. Place instrument on ground adjacent
to the rst mark on your measuring device.
7. Place foot on footpad.
8. Push the handle rmly forward.
9. Press and release the large black scan
button at the top of the handle (just below
the control box).
10. Move to the next test location (slice)
adjacent to the next 6 or 12 inch mark on the
measuring device.
11. Repeat steps 7-10 until scan distance
has been completed.
12. Press the C button to review the “Pipe
Map”.
13. Mark the locations on the ground
adjacent to the measuring device as shown
on the APL.
14. Move measuring device forward or
backward 6-10 ft away from current location.
Repeat steps 6-13.
15. Repeat scan process as needed to
mark location.
16. Review marks to determine direction of
pipe.
17. To turn off hold the power button until
the display turns off (after 5 beeps).
ULTRA-TRAC®APL
QUICK-START INSTRUCTIONS