UNIVERSAL COUNTER RPM 111
OPERATING MANUAL
Edition: March 2015 - Vers. 1.30
ASSEMBLAD - Technical office - A tomotive Division
EN

ASSEMBLAD RPM 111 = Operating manual
ASSEMBLAD S.r.l. - 50013 Campi Bisenzio - Firenze - Italy
2
I N D E X
1 NORMS AND GENERAL WARNINGS............................................................. 3
1.1 NOTE FOR THE USERS............................................................................... 3
2 TECHNICAL DATA .......................................................................................... 4
3 DESCRIPTION ................................................................................................. 5
3.1 UPPER PANEL................................................................................................ 5
3.2 LOWER PANEL............................................................................................. 5
3.4 ACCESSORIES.............................................................................................. 7
4 INSTALLATION................................................................................................ 7
4.1 TRANSPORT AND INSTALLATION .............................................................. 7
4.2 POWER UP .................................................................................................... 7
5 OPERATION .................................................................................................... 8
5.2 POWER UP OF THE INSTRUMENT ............................................................ 8
5.3 STANDARD MEASURE ................................................................................. 9
6 LCD AND KEYBOARD .................................................................................. 10
6.1 LCD DISPLAY ............................................................................................. 10
8 WARRANTY ................................................................................................... 11

ASSEMBLAD RPM 111 = Operating manual
ASSEMBLAD S.r.l. - 50013 Campi Bisenzio - Firenze - Italy
3
1 NORMS AND GENERAL WARNINGS
The RPM 111 is an RPM counter device for automotive engines, 2 and 4 strokes from 1 to
20 cylinders.
Please read carefully this manual before operating on the equipment and follow the
instructions when doing any action on it, in particular when doing maintenance
procedures.
Open the equipment only when explicitly indicated. Then, at the end of operations, close it
restoring its original conditions, in particular the casing and the gasket, before switching on
it again.
The manufacturer disclaims any responsibility for any kind of event arising from a
improper use of the equipment or for a procedure not explicitly described on this manual.
In any case, the responsibility is limited to the repair of the instrument.
For more detailed information please read the chapter “Warranty”.
The equipment performs measures in conformity with the Italian Ministerial Decree of law
n. 628 of 23/10/1996 and following modifications as Circular n. 88/95 of 06/09/1999
1.1 NOTE FOR THE USERS
The symbol of a “crossed” urban trash-bin is stamped on the equipment or on
its box and it means that the product must be disposed into the appropriate collecting
facility at the end of its life.
The disposal of the equipment will be managed by the producer. The user shall contact
the producer and follow the method that has been implemented for collecting the
appliance at the end of its life.
A correct waste disposal of the appliance and its subsequent treatment contributes to
avoid serious environmental and health damages and allow the recycling of materials
used into the equipment.
An incorrect waste disposal of the product is subject to administrative sanctions.
In accordance with art. 13 – D.L. 25 J ly 2005 – n. 151 for the Act ation of E ropean Directives 2002/95/CE, 2002/96/CE and
2003/108/CE, related to red ction of dangero s s bstances in the electric appliance and to the waste disposal (RoHS RAEE).

ASSEMBLAD RPM 111 = Operating manual
ASSEMBLAD S.r.l. - 50013 Campi Bisenzio - Firenze - Italy
4
2 TECHNICAL DATA
MEASUREMENT RANGE
RPM 300 ÷ 9999 giri/1' Res. 1 rpm / 1'
Oil Temperature 0 ÷ 150 °C Res. 1 °C
OPERATING FEATURES
Power supply - from 10 to 28 Volt DC (vehicle battery)
Operation temperature - from 0 to 40°C
Consumption - 0,5 A DC
Size - 100 x 220 x 40 mm
Weight - 0,4 Kg circa
DISPLAY - LED - KEYBOARD
N. 1 LCD 2 x 16 characters
N. 2 LED green and red color.
N. 6 Keys.
CONNECTIONS
USB interface
Bluetooth interface

ASSEMBLAD RPM 111 = Operating manual
ASSEMBLAD S.r.l. - 50013 Campi Bisenzio - Firenze - Italy
5
3 DESCRIPTION
3.1 UPPER PANEL
3.2 LOWER PANEL
Power s pply and
EOBD connector
Magnetic sensor and
antenna connector
Temperat re
sensor connector
USB connector

ASSEMBLAD RPM 111 = Operating manual
ASSEMBLAD S.r.l. - 50013 Campi Bisenzio - Firenze - Italy
6
3.3 FRONT PANEL
LCD
cylinder and stroke.
selection detection mode
selection
Power on
led power on led power s pply
Power off

ASSEMBLAD RPM 111 = Operating manual
ASSEMBLAD S.r.l. - 50013 Campi Bisenzio - Firenze - Italy
7
3.4 ACCESSORIES
STANDARD ACCESSORIES
1) Magnetic vibration sensor
2) Battery cable
3) USB A – mini B cable
OPZIONAL ACCESSORIES
1) E.OBD interface for RPM 111
2) Oil temperature probe
3) Radio antenna sensor (racket)
4) Power supply 230 Vac for RPM 111
5) Bluetooth interface for master/slave connection
4 INSTALLATION
The installation is very simple and can be executed by the operator.
4.1 TRANSPORT AND INSTALLATION
Due to the reduced dimensions of instrument, the transport is executed manually; pay
attention particularly to avoid any hits and falls: the eventual damages deriving from these
causes are not covered by the guarantee.
It is suggested to conserve the packing for possible shipments of the apparatus for
periodic calibration, technical attendance, etc.
Connect cables in equipment to the respective connectors on the instrument.
4.2 POWER UP
The RPM 111 has an internal rechargeable battery, this allow to perform measurement
without external power supply, it is necessary to connect only the required sensors.
The battery life duration is variable under a lot of conditions, status of battery, connected
sensors, bluetooth connection and temperature, with a fully charged and good battery, in
detection mode it is about 1 hour.
To recharge the internal battery connect RPM111 to an external 12V battery with battery
cable or its power supply adapter or to an E-OBD connector, the red led on indicates the
presence of external power-on and battery charged is operative.
For best performance it is preferred to operate with an external power supply.
When operate with internal battery, the RPM battery detection is not active.

ASSEMBLAD RPM 111 = Operating manual
ASSEMBLAD S.r.l. - 50013 Campi Bisenzio - Firenze - Italy
8
5 OPERATION
5.1 WARNINGS AND PRECAUTIONS
- Verify that the voltage of the battery of the vehicle is that one prescribed in the
technical characteristics.
- Don’t let the instrument at the direct sunbeam, verify that ambient temperature is
compliant with instrument data.
- Do not put the magnetic probe in particularly warm places of the motor (es. exhaust
manifolds)
- Do not remove the systems of protection and/or emergency from the equipment, do
not bring modifications to the aim of increase the use or the performances.
- Do not leave for too long time the instruments operative; turn off the instrument if
an immediate use is not previewed.
- Pay attention to the DANGER or ATTENTION when operating on the motor .
- Protect face, hands and feet with adapted apparel, to avoid contacts with the
superficial warmth which candles, radiators, pipes of the cooling system. The
catalytic stock-pots catch up the highest temperatures, can cause burn or fires. Do
not smoke and do not use free flames when you work on the motor.
- In the vehicles the cooling fan is independently active also when the engine is off:
be careful when it is operating near the fan.
- Do not pull sensors or interfaces from its cables but use their connectors, make
attention to do not pull the wires. The disconnection of wires is not covered by
warranty.
- Do not use the oil temperature sensor in water, flame or other but only into the
motor oil. The wrong use is not covered by warranty.
- The complete discharge of the battery reduces its capacity and can damage it.
5.2 POWER UP OF THE INSTRUMENT
Turn on pushing the key ON for about one second. Turn off pushing the key OFF, this key
is active after the start-up messages.
After measurement, turn off the instrument to don’t discharge the battery.
After power on the instrument, on the LCD is reported the message for search the
connection with an USB port, if it is found there will be the message that this port is
configured, only in this condition the communication of data and the updated via USB is
working.
If the communication of data is made via bluetooth, the USB communication is not used.

ASSEMBLAD RPM 111 = Operating manual
ASSEMBLAD S.r.l. - 50013 Campi Bisenzio - Firenze - Italy
9
5.3 STANDARD MEASURE
Set the engine at minimum rate, connect the sensor or cable, turn on RPM111, select the
type of motor, number of cylinders and type of detection.
If the reading is wrong or not stable, search a new sensor position.
If the reading is stable, before to make the measurement, perform a slow acceleration and
deceleration, verify that the reading is regular in all the range.
Magnetic sensor
On the motor block search the point with maximum vibration, apply the sensor to a planar
metallic surface, if there is not a place to have sensor stability, apply a metallic tweezer
and apply over it the magnetic sensor, after turn on the RPM 111 and select VIB. If the
reading is not stable, move the sensor in a point where it will have a more regular
vibration.
Battery
Connect the tweezers of battery cable to the vehicle battery, turn on the vehicle lights, turn
on the RPM 111 and select BAT.
Antenna
Turn on the RPM 111, approach the planar surface of the antenna sensor (racket)
perpendicular to the cables of vehicle spark plugs, the detection of the radio noise is
marked with led flashing, to have a sound indication use an earphone. Verify the
instrument reading. If the antenna is too near or too far away to the cables, the reading will
be wrong and unstable.
E-OBD interface
Connect the interface to the vehicle and to the RPM 111, verify the red led on, turn on the
instrument and select the connection with EOBD, if the connection is not detected try to
turn off the instrument and after repeat the turn on and selection.
When the connection with EOBD interface is active, the instrument is powered from the
vehicle and the inside battery is recharged.
N.B.
The initial procedure must be executed with engine at minimum rate.
If the magnetic sensor is not used it is suggested to disconnect it from the instrument.
After measurement, turn off the instrument to don’t discharge the battery.

ASSEMBLAD RPM 111 = Operating manual
ASSEMBLAD S.r.l. - 50013 Campi Bisenzio - Firenze - Italy
10
R: 870 T: 83
VIB 4T 5 95
6 LCD AND KEYBOARD
6.1 LCD DISPLAY
When the instrument is powered on, the LCD shows if the USB connection is active, after
it shows the model, name and version of the firmware, after it shows the measure display,
an example is report below
In the first line there are reported the rpm and temperature values detected.
In the second line there are reported the detection mode, fuel type, number of cylinders
and battery level indication.
If rpm is not detected it is showed the symbol “---“
If the temperature is not detected it is showed the symbol “--“. When it is used the oil
probe, the temperature showed is the one detected from the sensor, if it is connected to
the E-OBD interface the temperature is the motor temperature received from the vehicle.
The detection mode can be one of the following:
VIB = vibration sensor
BAT – battery detection
ANT – antenna radio noise detection
IND – Induction clamp
EOBD – data received from E-OBD interface
6.2 KEYS
To select the detection mode press the key UP or DOWN
To change the fuel type or number of cylinders press the RIGHT or LEFT key, in front of
the value to change will be showed the symbol “>”, change the value with the keys UP or
DOWN, exit with its selection.
Be careful to the use of the selection RESTORE, this delete all instrument data and it
restores the default ones.

ASSEMBLAD RPM 111 = Operating manual
ASSEMBLAD S.r.l. - 50013 Campi Bisenzio - Firenze - Italy
11
8 WARRANTY
This device was built with care and carefully inspected before it left the factory. It is
guaranteed for one year from the date of purchase by the final user.
The warranty covers all defects in materials.
The warranty does not cover: wiring, probes, sensors and the accessories.
These items are subject to wear and their efficiency depends on how they are handled.
The warranty does not cover damage caused by accidents, impact or dropping the
instrument, or by negligence, improper use, non-compliance with the instructions and
improper storage.
If the device has such defects as to require technical service, you must return it to
Assemblad or an authorized service centre. Shipping charges shall be covered by the
customer.
ASSEMBLAD, even supplying support on demand for the first installation of the
equipment, disclaims any liability for damages and injuries caused, even to third parties,
by an improper installation, maintenance, defective or unsafe electrical connections.
Further, ASSEMBLAD disclaims any claim for damages from anyone due to a miss
utilization of the equipment for any reason.
The warranty shall immediately become invalid if the device shows any signs of
tampering.
The exclusive court of jurisdiction for any disputes arising from the application and/or
interpretation of this warranty is the Court of Florence (Italy).

ASSEMBLAD RPM 111 = Operating manual
ASSEMBLAD S.r.l. - 50013 Campi Bisenzio - Firenze - Italy
12
COPYRIGHT
by
ASSEBAD Sr
Via della Querce, 6°/6b
50013 Campi Bisenzio - (Florence) - ITALY
Tel. +39 055 890485 Fax +39 055 890496
http:// www.assemblad.it
E-Mail: info@assemblad.it
Reproduction and/or disclosure prohibited
2014/30/UE
2014/35/UE
EN 61010-1
EN 61326-1
and
are Registered Trademark
Table of contents
Other ASSEMBLAD Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Ludlum Measurements
Ludlum Measurements 18 manual

Tektronix
Tektronix 491 Maintenance manual

Topcon
Topcon FC-2600 Operator's manual

Anton Paar
Anton Paar Quantachrome ULTRAPYC UPY-32 operating manual

Lovibond
Lovibond SD 300 pH instruction manual

Larson Electronics
Larson Electronics LZRWL-CRN-RED-200MW-120V quick start guide

Met One Instruments
Met One Instruments BX-807 Operation manual

Kathrein
Kathrein MSK 125 operating manual

Endress+Hauser
Endress+Hauser Proline Prowirl 72 operating instructions

CruzPro
CruzPro WSD110 manual

RaySafe
RaySafe i3 Instructions for use

Sierra Monitor Corporation
Sierra Monitor Corporation 5100-03-IT manual