SET SET-2090 Parts list manual

1 of 10
www.smart-e-tech.com
SET-2090
Technical Description
Issue 05 02.06.23
INTERNAL - NI CONFIDENTIAL
TECHNICAL DESCRIPTION
SET-2090
32 Channels Pass Through
This document 9040TDD0360 is a technical description of the SET-2090.
Note
Before you begin, complete the Software and Hardware installation
procedures applicable to your application.
Note
The guidelines in this document are specific to the SET-2090. The other
components in the system might not meet the same safety ratings. Refer
to the documentation of each component in the system to determine the
safety and EMC ratings for the entire system.
MORE INFORMATION ON OUR WEBSITE:
www.smart-e-tech.de/slsc

2 of 10
www.smart-e-tech.com
SET-2090
Technical Description
Issue 05 02.06.23
INTERNAL - NI CONFIDENTIAL
Safety Guidelines
Caution Do not operate the SET-2090 in a manner not specified in this document.
Product misuse can result in a hazard. You can compromise the safety protection built
into the product if the product is damaged in any way. If the product is damaged, return
it for repair.
Electromagnetic Compatibility Guidelines
This product was tested and complies with the regulatory requirements and limits for
electromagnetic compatibility (EMC). These requirements and limits provide reasonable
protection against harmful interference when the product is operated in the intended
operational electromagnetic environment.
This product is intended for use in industrial locations. However, harmful interference may
occur in some installations, when the product is connected to a peripheral device or test
object, or if the product is used in residential or commercial areas. To minimize interference
with radio and television reception and prevent unacceptable performance degradation,
install and use this product in strict accordance with the instructions in the product
documentation.
Furthermore, any changes or modifications to the product not expressly approved by SET
GmbH could void your authority to operate it under your local regulatory rules.
Caution
To ensure the specified EMC performance, operate this product only with
shielded cables and accessories.
Caution
To ensure the specified EMC performance, the length of any cable
attached to connectors J1 and J2 must be no longer than 3 m (10 ft).
ROHS Compatibility Guidelines
This product is fulfill the RoHS Directive 2011/65/EU on the restriction of the use of certain hazardous
substances in electrical and electronic equipment.

3 of 10
www.smart-e-tech.com
SET-2090
Technical Description
Issue 05 02.06.23
INTERNAL - NI CONFIDENTIAL
Description
The SET-2090 device is an experimental card for NI-SLSC and provides 32 differential inputs.
The input signals can be configured by customers. Each input channel can be tested,
conditioned, or measured in different ways. Various inductors, filters, pull-up, or pull-down
resistors can be used for this purpose. In standard configuration, the input signals are
transmitted directly to the output.
Circuitry
Note
Diagram only shows one channel. All components without a labeling, are
optional.
The “Ref.” Signal from the block diagram below is each connected to the
corresponding Reference Signals on the Front connector. Per connector 4
Reference Signals are available, mapping each to four differential signals.
For example, the “Ref.” from channel “P0.0” is connected to the “Ref_0” signal
which is on “J1” and shared for channel “P0.0” to “P0.3”.
Ref_0
Is for channel P0.0-P0.3
Ref_4
Is for channel P4.0-P4.3
Ref_1
Is for channel P1.0-P1.3
Ref_5
Is for channel P5.0-P5.3
Ref_2
Is for channel P2.0-P2.3
Ref_6
Is for channel P6.0-P6.3
Ref_3
Is for channel P3.0-P3.3
Ref_7
Is for channel P7.0-P7.3
J1_Spare
Is for channel P0.0-P3.3
J2_Spare
Is for channel P4.0-P7.3
All voltages are relative to GND unless otherwise noted.

4 of 10
www.smart-e-tech.com
SET-2090
Technical Description
Issue 05 02.06.23
INTERNAL - NI CONFIDENTIAL
15
30
44
14
29
43
13
28
42
12
27
41
11
26
40
10
25
39
9
24
38
8
23
37
7
22
36
6
21
35 5
20
34
4
J1, J2 Pinout (Front)
J1 J2
Signal
Description
Px.y
Line y Port x
GND
Ground connection
NC
No connection
J1, J2 Connector Pin Assignments
15
30
44
14
29
43
13
28
42
12
27
41
11
26
40
10
25
39
9
24
38
8
23
37
7
22
36
6
21
35
5
20
34
4
19
33
3
18
32
2
17
31
1
16
P3.2+
P3.2-
P3.1+
P3.1-
P3.0+
P3.0-
NC
NC
P2.2+
P2.2-
P2.1+
P2.1-
P2.0+
P2.0-
J1_Spare
GND
P1.2+
P1.2-
P1.1+
P1.1-
P1.0+
P1.0-
NC
NC
P0.2+
P0.2-
P0.1+
P0.1-
P0.0+
P0.0-
P3.3+
P3.3-
REF_3
REF_2
P2.3+
P2.3-
GND
GND
P1.3+
P1.3-
REF_1
REF_0
P0.3+
P0.3-
15
30
44
14
29
43
13
28
42
12
27
41
11
26
40
10
25
39
9
24
38
8
23
37
7
22
36
6
21
35
5
20
34
4
19
33
3
18
32
2
17
31
1
16
P7.2+
P7.2-
P7.1+
P7.1-
P7.0+
P7.0-
NC
NC
P6.2+
P6.2-
P6.1+
P6.1-
P6.0+
P6.0-
J2_Spare
GND
P5.2+
P5.2-
P5.1+
P5.1-
P5.0+
P5.0-
NC
NC
P4.2+
P4.2-
P4.1+
P4.1-
P4.0+
P4.0-
P7.3+
P7.3-
REF_7
REF_6
P6.3+
P6.3-
GND
GND
P5.3+
P5.3-
REF_5
REF_4
P4.3+
P4.3-

5 of 10
www.smart-e-tech.com
SET-2090
Technical Description
Issue 05 02.06.23
INTERNAL - NI CONFIDENTIAL
J1, J2 Pinout (Front)
J1
XJ2
J2
XJ2
P0.0+
I/O_0+
P4.0+
I/O_16+
P0.0-
I/O_0-
P4.0-
I/O_16-
P0.1+
I/O_1+
P4.1+
I/O_17+
P0.1-
I/O_1-
P4.1-
I/O_17-
P0.2+
I/O_2+
P4.2+
I/O_18+
P0.2-
I/O_2-
P4.2-
I/O_18-
P0.3+
I/O_3+
P4.3+
I/O_19+
P0.3-
I/O_3-
P4.3-
I/O_19-
P1.0+
I/O_4+
P5.0+
I/O_20+
P1.0-
I/O_4-
P5.0-
I/O_20-
P1.1+
I/O_5+
P5.1+
I/O_21+
P1.1-
I/O_5-
P5.1-
I/O_21-
P1.2+
I/O_6+
P5.2+
I/O_22+
P1.2-
I/O_6-
P5.2-
I/O_22-
P1.3+
I/O_7+
P5.3+
I/O_23+
P1.3-
I/O_7-
P5.3-
I/O_23-
P2.0+
I/O_8+
P5.0+
I/O_24+
P2.0-
I/O_8-
P6.0-
I/O_24-
P2.1+
I/O_9+
P6.1+
I/O_25+
P2.1-
I/O_9-
P6.1-
I/O_25-
P2.2+
I/O_10+
P6.2+
I/O_26+
P2.2-
I/O_10-
P6.2-
I/O_26-
P2.3+
I/O_11+
P6.3+
I/O_27+
P2.3-
I/O_11-
P6.3-
I/O_27-
P3.0+
I/O_12+
P7.0+
I/O_28+
P3.0-
I/O_12-
P7.0-
I/O_28-
P3.1+
I/O_13+
P7.1+
I/O_29+
P3.1-
I/O_13-
P7.1-
I/O_29-
P3.2+
I/O_14+
P7.2+
I/O_30+
P3.2-
I/O_14-
P7.2-
I/O_30-
P3.3+
I/O_15+
P7.3+
I/O_31+
P3.3-
I/O_15-
P7.3-
I/O_31-
Front Panel Signal Descriptions

7 of 10
www.smart-e-tech.com
SET-2090
Technical Description
Issue 05 02.06.23
INTERNAL - NI CONFIDENTIAL
Row
e
d
c
b
a
1
I/O_1-
I/O_1+
NC
I/O_0-
I/O_0+
2
I/O_3-
I/O_3+
NC
I/O_2-
I/O_2+
3
GND
GND
GND
GND
GND
4
I/O_5-
I/O_5+
NC
I/O_4-
I/O_4+
5
I/O_7-
I/O_7+
NC
I/O_6-
I/O_6+
6
GND
GND
GND
GND
GND
7
I/O_9-
I/O_9+
NC
I/O_8-
I/O_8+
8
I/O_11-
I/O_11+
NC
I/O_10-
I/O_10+
9
GND
GND
GND
GND
GND
10
I/O_13-
I/O_13+
NC
I/O_12-
I/O_12+
11
I/O_15-
I/O_15+
NC
I/O_14-
I/O_14+
15
I/O_17-
I/O_17+
NC
I/O_16-
I/O_16+
16
I/O_19-
I/O_19+
NC
I/O_18-
I/O_18+
17
GND
GND
GND
GND
GND
18
I/O_21-
I/O_21+
NC
I/O_20-
I/O_20+
19
I/O_23-
I/O_23+
NC
I/O_22-
I/O_22+
20
GND
GND
GND
GND
GND
21
I/O_25-
I/O_25+
NC
I/O_24-
I/O_24+
22
I/O_27-
I/O_27+
NC
I/O_26-
I/O_26+
23
GND
GND
GND
GND
GND
24
I/O_29-
I/O_29+
NC
I/O_28-
I/O_28+
25
I/O_31-
I/O_31+
NC
I/O_30-
I/O_30+
XJ2 Connector Pin Assignments
Signal
Description
I/O
Input/Output
GND
Ground connection
NC
No connection
XJ2 Connector Signal Descriptions

9 of 10
www.smart-e-tech.com
SET-2090
Technical Description
Issue 05 02.06.23
INTERNAL - NI CONFIDENTIAL
LED Behavior
LED Name
LED Behavior
Definition of Behavior
PWR
Off
No power present on the board
Solid green
Power good state
RDY
Off
Module card is unpowered
Solid green
Card is recognized by the chassis and ready to
communicate
Solid amber
Module card is booting
Blinking
amber
Chassis is communicating with the module card
Error Handling
LED Name
LED Behavior
Actions
PWR
Off
-Checking the power supply of the chassis
-Checking the external power supply if used
RDY
Off
-Checking the power supply of the chassis
-Checking the external power supply if used
Solid amber
-Waiting till boot process is finished
Blinking
amber
-Waiting till communication is finished
-if communication does not finish, shut down all
operations and reboot chassis
Hardware Specifications
Absolute Maximum Ratings
Property
Condition
Value
Comment
Relative humidity
5% to 95%
Non-condensing
Temperature
0°C –85°C
Storage
-40°C-85°C
Max. Input Voltage
Any Pin
60 Vdc
Limited by connector
Min. Input Voltage
Any Pin
-60 Vdc
Limited by connector
Max. Current rating
1.5 A
2 A transient

10 of 10
www.smart-e-tech.com
SET-2090
Technical Description
Issue 05 02.06.23
INTERNAL - NI CONFIDENTIAL
Physicals Characteristics
Property
Condition
Value
Comment
Module dimensions
Excluding ejector
144.32 mm x 30.48 mm
x 302 mm (H x W x D)
Standard SLSC card
size
Front Panel Connector
2x female HD-44
D-Sub with 4-40 UNC
screw lock
For mating connectors
and cables, see below
RTI Connector
2 mm hard metric per
IEC 61076-101
Any RTI marked
Environmental
Property
Condition
Value
Comment
Operating humidity
Relative, non-
condensing
10%-90%
Storage humidity
Relative, non-
condensing
5%-95%
Operating
temperature
Forced-air cooling
from chassis
0°C-85°C
Storage temperature
-40°C-100°C
Maximum altitude
2000 m
Table of contents
Other SET Network Hardware manuals
Popular Network Hardware manuals by other brands

Paradyne
Paradyne MCC installation instructions

ADTRAN
ADTRAN Total Access 1500 Total Reach DDS-DP Installation and maintenance guide

Patton electronics
Patton electronics DigiLink-V 2530 user manual

Digi
Digi Connect ME Hardware reference

MIKRODEV
MIKRODEV RTU Series Hardware manual

Cisco