SGS Household Oxygen Bar User manual

Operating Instructions
Household Oxygen Bar
Machine No:1.1
Part No:416-00501-190E
O2
Oxygen co-
ncentration
Oxygen
Minute
Oxygen
flow
!
Cumulat-
ive time
Spray
Power
supply Anion
O2
Oxygen co-
ncentration
Oxyge n
Minute
Oxygen
flow
!
Cumulat-
ive time
Spra y
Power
supply Anion
Operating Instructions
Household Oxygen Bar
The specification, color and configuration of models listed in thismanual are subjected to the
real models showed on marketwithout notice.

Dear users,
The instructions introduce the function characteristics of
this product, operation steps, notes and maintenance in d-
etail.
In order to ensure that you can use the product more effec-
tively, please read this manual carefully before use and k-
eep it safe after reading.
Without permission, cannot take apart products in person
, otherwise, you will lose the warranty.
Be careful, the company reserves the rights to update pro-
ducts and technology, Some illustrations in the specifica-
tion you see in the product may be different, received in -
kind prevail.
Thank you for purchasing our products, wish you use happily.
Without reading this manual, please don't operate the pro-
duct. If you have any questions on the understanding of t-
his manual, please contact the seller or after-sales techni-
cal personnel, don't take action to operate the product, or
it may result in serious personal injury or property damage.
Preface
Warning

08
09
10 11
12
Notes
Product Features
Installation and
Operation
Maintenance
Problem Investigation
and Trouble Shooting
Working Principle
Catalogue
Warning
Note
Safety Precautions
Cautions:
To prevent blackouts or household oxygen bar may break down, someone
who are urgently needed oxygen must be configured with a much-needed
backup support to other devices (such as: oxygen cylinder, oxygen bags,
etc.), it is not considered for the life of the equipment or the use of the co-
ntinuation of life.
Oxygen may cause combustion, no smoking when operating the oxygen bar
When in a heat environment, sparks and open flames and other factors, do
not use household oxygen bar.
There is high-voltage in household oxygen bar, please do not disassemble.
All parts of the product, after rigorous testing, safety and reliability, so do
not use this product with other accessories made by other manufactures ot-
herwise it will affect the performance.
Moving household oxygen bar by the cord or hose is prohibited.
This product with rated voltage of 220V, please use secure socket qualified.
To prevent accidents, do not let children operate the oxygen bar. When b-
reathing oxygen, not let the hose around the neck. When the elderly using
the oxygen, a guardian must beside him.
Household oxygen bar works as a direct separation of oxygen from air, w-
hich is used for breathing, so do not use in smoke, toxic and harmful gases
environments.
Before the first use, please roll household oxygen bar, then cut off the bo-
ttom of the transport fixed ties, see "Cut ties description".
When this product is working, there will be intermittent exhaust sound,
which is a normal phenomenon.
When add water to wet cup, do not exceed the maximum water level. Wh-
en handling household oxygen bar, need to pour out the water in wet cup,
so as not to cause backflow.
Please confirm whether the oxygen outlet, the air intake vents behind ox-
ygen bar is blocked, in order to avoid downtime caused by high temperature.
This product only applies to household oxygenating, cannot be used as
medical treatment.
12
IS O 9 0 0 1
13
ISO13485

Product Features
This product uses the air as raw material,AC220V power as power source,
uses a good original zeolite by French and the air compressor ,
Through advanced pressure swing adsorption separation in room temperature,
extraction of high-purity oxygen by air, stable oxygen, safe and reliable, this
method is called pure physical methods.(Refers to working principle on p-
age 12) .
Intelligent Control:
IMD beautiful large color panel, easy to operate, large color LED screen, cl-
ear display, timer operation function and with infrared remote control, let it
be easier and more convenient.
Anion:
Multi-layer filter, self-easy to replace:
The oxygen system of this product have coarse dust filter, fine dust filter and
three bacterial filtration treatment for the input air respectively, finally, the
oxygen is fresh and clean when output , and the front floor filter can be repl-
aced without disassemble, the user operate it comfortably.
Temperature: 5~35℃ Relative humidity:≤80%
Range of the atmospheric pressure: 0.086 MPa -0.106 MPa
When the temperature is higher or lower, do not use oxygen bar.
5000 hours lifespan
This machine is equipped with ion function, and a "negative" button; the neg
ative ion system can work alone , you can also work simultaneously with the
oxygen system;Anion generatorAir vents located in the machine, the exhaus
t vents discharged into the surrounding space of the machine when working.
Product Introduction
Functional characteristics
Using environment
01 02
Product Features
Technical parameters
Product name: household Oxygen Bar
Scope of application: use as household oxygenating,
not use for medical treatment
Model:
Air output:
PSA methods: PSA
The input power: 115w
Rated voltage: AC 220 v, 50 Hz
Current rating: 0.5 A
Oxygen concentration: 3 0~90%(adjustable)
Output pressure: <100kpa
Negative oxygen ion: ≥ 6 million particles/ cm ³
Noise: about 48db
Product size: 302 * 168 * 325 mm
Net weight: 5.2kg
Electrical categories:
Execution standard: GB4706.1-2005
Execution standard:
CE Certificate

Installation and Operation
03 04
Opening instructions
Oxygen packing, please check the items in the box whether it complete or in
tact according to the manual attachment list. Otherwise, please contact reta-
iler or manufacturer.
Appearance diagram:
Oxygen air outlet
Display screen
Wet cup
Air intake (filter)
Power switch
Insurance holder
Power cord socket
Cooling air outlet
Cooling air inlet
O2
Oxygen co-
ncentration
Oxygen
Minute
Oxygen
flow
!
Cumulat-
ive time
Power
supply Anion
Installation and Operation
Screen shows
Power light
Oxygen production light Anion light
Elapsed time display
Timing key
Oxygen key Negative ionic bond
Fault indicator light
Oxygen flow rate display
ON/OFF button
Oxygen concentration
display
O2
Oxygen co-
ncentration
Oxygen
Minute
Oxygen
flow
!
Cumulat-
ive time
Power
supply Anion

Installation and Operation
05 06
Power operation and components using
Water cup (add water):
The left and right index finger were inserted into a crescent above vacancy
wet cup, press and hold the remaining fingers around the body, index finger
pressed under wet cup, and then pull out, you can remove the wet cup, un-
plug the humidifier on the back of the cup silicon capsules adding stone tre-
nch Officials pure water or boiled water, added water cannot exceed the m-
aximum tire indicator line, plug silicon capsule well, and then connect the -
power cord into the fuselage, power on.
Connect the power cord, power on
Put the tail end of the power cord into the power cord socket household ox-
ygen bar, and the other end connected to the indoor outlet, after power, the
power switch is turned on, after the first power, microcomputer will autom-
atically start the self-test all the bright lights of a display about 2 seconds
(including the "failure" indicator), colleagues buzzer will sound prompt,
after the self-test, automatically restore the standby mode and displays the
default time "015", "power jack" and "power switch" position, see section
appearance of page four.
Silicon capsule Highest lines
Installation and Operation
O2
Power on: ON/OFF button
In standby mode, press the "ON / OFF" to wake up the machine and start wo-
rking, and "oxygen" light will be lit, the default length of 15 minutes, turn off
the machine by complex back to standby.
Timing
Click the "timing" until showing the length of time.
After finish working, the display window will return to standby mode and w-
aits for the user to use: If you do not use for more than ten minutes (tempera-
ment cooling system is running for about five minutes), will enter power-sa-
ving sleep state (Note: the premise is not open anion state ), then "Power" w-
ill flash to alert the user who can press the power switch back to the off state
(power switch location, see appearance diagram on page four), you need to
continue to use, press the "ON / OFF" button to start the machine, return to
standby mode and waits for the user to use.
Anion
According to users' needs, you can open anion function, click "anion" to open,
and display "anion" light will be lit (see screen instructions on page five), p-
ress twice means close.
Transfer oxygen
According to users' needs, you can choose different oxygen concentrations,
tap tune oxygen can get a good set of different gears, the display will also sh-
ow the corresponding oxygen flow.

O2
Oxygen co-
ncentration
Oxy gen
Minute
Oxygen
flow
!
Cumulat-
ive time
Power
supply Anion
Installation and Operation
07 08
Catchment use (sold separately)
Oxygen inhaler
Outlet E
Household oxygen bar outlet
Gas port B
Note that there is the
inlet end of the catheter
Highest water line
Put one end of the first conduit to the sump plug inlet port B (with the inlet
conduit, as difference) A is inserted into the other end connected to the ox-
ygen outlet household oxygen bar, and finally the end of the oxygen duct
plug to the integrated water heater outlet E.
When the water level inside the catchment exceeds the maximum water lev-
el D, please promptly drained the water to avoid water back into the oxygen
tube.
Rmote control use
With a dedicated remote control, this product gets the remote control align-
ment infrared receiver hole of oxygen machine panel.
When you find the remote control operation insensitive and cannot operate,
you must check the remote control battery whether it fully charged first; re-
mote control can't be too far from the host computer, otherwise it will lead
to the remote control operation insensitive.
Infrared receiver
The oxygen machine has smooth appearance, glossy, please prevent the
sharp scratch it.
Please turn off the oxygen machine after finishing the timer and the air s-
upply, and unplug the power in time.
The cotton filters on the host side change in time, if the cotton filters we-
re blocked by the dirty stuff, it will have an effect on oxygen.
Attention:
Please don't take apart the machine by yourself, avoid unnecessary dam-
age inside the machine, before cleaning and maintaining, oxygen machine
must be cut off the power.
1.Routine maintenance
2.Handle of long idle
Starting up, let the oxygen machine work for thirty minutes, then wait for
it to cool by natural.
Cut off the power, replace the oxygen machine into the box.
Remote control can't install battery while sealing, in order to prevent the
battery leakage to damage the remote control.
Pls wrap and seal the main engine with plastic bags to prevent air humidity
cause the machine performance degradation.
Remove the wet cup, drain the water out of the cup and replace host comp-
uter after air-dry.
The maintenance of wet cup:
In order to ensure the cleaning of the wet cup, the injection should be pu-
re water or boiled water, and try to replace every day, we suggest users c-
leaning the wet cup once a week
Air filter maintenance:
The main function of the air filter is filter and adsorption the dust and im-
purity, a long time will form a blockage in turn affect the intake of oxygen
machine oxygen effect.
It will become intake block for a long time, thereby, have an effect on the
oxygen machine; generally, replaced once a quarter, if it has much dust,
recommend replacing every two months.
3.Parts maintenance
Maintenance

10
Problem Investigation and Trouble Shooting
Symptom Possible Cause Solution
Household oxygen
bar cannot operate
properly, the power
indicator light is not
bright.
The power line is not conne-
cted to a power outlet.
Power supply socket without
electricity.
Overload protection burning fuse
Power cord is not for good in
the household oxygen bar or
power cord bad.
Check whether the socket outlet connection
is normal.
Replace the electric socket.
Open the insurance and replace the fuse.
Unplug reinsert the fuselage outlet or repl-
ace a power supply cord.
The screen display
normal, but the oxy-
gen bar does not ha-
ve normal operation
soun.
Household oxygen bar over-
heating protection.
Household oxygen bar com-
puter froze plate.
The compressor function b-
reakdown.
Make sure the place has been away from ho-
usehold oxygen bar curtains, bake warm m-
achines, heaters and fireplaces, and confirm
household oxygen bar and walls or other o-
bjects around the retention gap of at least
20 cm.
Turn off the machine, wait five minutes to
restart.
Contact household oxygen bar retailer or m-
anufacturers.
Full screen flash,
while alarm. Internal hardware damage Returned to the manufacturer or dealer for
repair.
Big Noise Ties are not cut, the machine
did not put a smooth. Cut ties, put the machine steady.
The screen display
normal and hear n-
ormal operation so-
und but no anoin o-
xygen output.
Intake window cotton filters
is dirty, cause block.
Household oxygen bar internal malfunction.
Cut off the power switch, r-
eplace window air intake fi-
lter cotton. Contact the household seller or manufactu-
rers.
Press to adjust the
time when the tra-
nsfer is invalid.
Sleep tone when keys are lo-
cked, inoperable.
Press the "On / Off" button to wake, the key
to adjust the time and then tune.
09
Problem Investigation and Trouble Shooting
Symptom Possible Cause Solution
The oxygen machine
emits poof bared s-
ound six-minute int-
ervals.
Water coming out
of the mouth of o-
xygen.
the machine is op-
erating normally -
after starting up,
but have a narrow
minded.
Oxygen odor
The machine emits exhaust
sound.
Adding too much water in the
wet cup(exceed the highest
water level),airflow will
push oxygen tube blisters.
Difference temperature , ca-
use the humidified oxygen in
the wall that moisture will c-
ondense water out of cold.
Flow value is too small.
Oxygen tube was twisted or
flatten.
Early use, series of tubes or
other plastic will emit odor,
is a normal phenomenon.
If the machine emits poof bared sound reg-
ularly is a normal phenomenon, discharge
the sound of nitrogen.
The water in the wet cup have reduced to the
highest water level.
Pour the water out of the wet cup, starting
up, after fifteen minutes ,waiting the dropl-
ets are dried in the oxygen tube, then adding
water into the wet cup.
Turn up flow
1. Tank silicone stopper loose, remove the
tank and the silica gel plug impaction.
2. The tank did not put into the machine in
place, should be put into the tank with a lit-
tle push.
3. The gas tank has two aprons in and out of
the mouth, if not installed well, it can lead
to leakage.
This odor is normal smell emitted by the sil-
icone tube, which has been detected by non
toxic, and with the use of the machine, the
smell will gradually disappear.

12
Working Principle
Muffler
Coarse filter (level 1)
Dust filter (level 2)
Oil-free air compressor
Nitrogen exclude (silencer)
One-piece molecules
containing separation
valve tower
Bacterial filter
Wet cup
Oxygen outlet
Electronic control module
11
ISO9001
压针孔线

13
ISO13485
压针孔 线