SHENZHENGUIYUANINDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com E-Mail: sale@carymart.com
RF Wireless Receiver (Model 0020348 S1DA-DC12)
Feature:
Application: It can be used in industry automation, agriculture automation and home automation, such as factory, house,farm, pasture, vehicle, ship,
offshore operation, aerial vehicle, field call, etc. It can remote control equipments on land,water and air, such as remote control lights, sirens, locks,
motors, fans,winches, blinds, linear actuators, doors,windows, electricsolenoid valves,security alarm, business signs and various devices.
Wireless control, easy to install.
Waterproof: The receiver haswaterproof caseandwaterproof connector, itcan be installed outdoors.
Relay Output: This receiver is relay output,it can beused to operate both DCandACequipments. The terminal is NO / NC(normally open / normally
closed),whichserves as aswitch. That meansyoushould alsoconnect a separatepowersupply to it.
Withwiredcontrol terminals: Youcanconnect sensors, limit switches, manual sw itches or external devices tocontrol the receiver.
Adjustable delay time: 0 seconds ~ 99 hours
Designwith low-power andhigh-speed CMOS technology.
Youcan turnon/ off thereceiverwith transmitter (remote control) fromany placewithin a reliable distance.
Wireless RF signal can pass throughwalls, floors, doors or windows.
With reverse power protection andover current protection.
Reliable control: The receiver only workswith the transmitter w hich usesame code.
One/several transmitters can control one/several receivers simultaneously.
Youcan use two or more units in thesame place.
Receiver:
Model No.: S1DA-DC06 / S1DA-DC09 / S1DA-DC12 / S1DA-DC24
Pow er Supply (Operating Voltage): DC6V (S1DA-DC06), DC9V±1V (S1DA-DC09), DC12V±1V (S1DA-DC12), DC24V±1V (S1DA-DC24)
Output: Relay output (Normally open and normally closed)
Working Voltage Range of Relay:AC110~240V or DC0~28V
Transmitting Frequency: 315MHz / 433MHz
Channel: 1 CH
Control Mode: Delay (Press -> ON; Then OFFafter the delay time)
Adjustable delay time: 0 seconds ~ 99 hours
MaximumWorking Current: 10A / eachchannel
Static Current: ≤6mA
PCB size: 140mmx 73mmx 18mm
Case size: 192mmx 100mmx 45mm
Workwith Fixedcode transmitters or Learning code transmitters.
Matching Transmitters:
The receiver canworkwith different transmitters,suchas model C-1 / C-2 (100M), CWB-1 / CWB-2 (50M,waterproof), CP-1 / CP-2 /CV-2(500M), or
CB-1 / CB-2 (1000M), CBW-1 / CBW-2 (1000M,waterproof) etc.
Working Range:
With a transmitter (such as C-2) to forma complete set, theworking distance can reach 100Min an open ground. The maximumworking distance
100M is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, itwill be hindered by trees,
walls or other constructions, andw ill be interferedby otherwireless signals.Therefore,the actual distancemay or may notreach 100M. If youwant to
have a further working range, you can install an external antenna to the receiver, and you also can use a powerful transmitter, such as CB
transmitters.
Usage (with the transmitter C-2):
The receiver can be used to control both DC 0~28V andAC110~240V equipments.
Notice: The receiver is relay output, not DC/ACpower output.Initialstate of relay outputterminals: Terminals A and B are Normally Open; Terminals A
and Care Normally Closed.
If youwant to control a DC 12V lamp, do as following:
1) Connect the positive pole of DC pow er supply to terminal “L / +”, andconnect the negative pole of DCpow er supply to terminal “N / -”.
2) Connect terminal C to the positive pole of DC power supply,connect terminalB to the positive pole of DC lamp, and connect the negative pole of
DC lamp to the negative pole of DC pow ersupply.
If youwant to control anAC 220V lamp, do asfollow ing:
1) Connect the positive pole of DC pow er supply to terminal “L / +”, andconnect the negative pole of DCpow er supply to terminal “N / -”.
2) Connect terminal Cto the livewire of ACpower supply, connect terminal B to one side of AClamp, and connect anotherside of AClamp to the
neutralwire of ACpower supply.
Press button 1: Turn onrelay (connect B and C, disconnectA and B), the lamp is on.
After delay time: Turn off relay by itself (disconnect B and C, connectA and B), the lamp is off.
Press button 2: Turn off relay immediately, no need towaitfor delay time.
Press buttons of “+”and“-”on the timer, adjust delay time from0 second to99 hours. “H”is Hour, “M”is Minute, and “S”is Second.
For example, if you set “S 0 1”, it means the delay time is 1 second.