SHENZHENGUIYUANINDUSTRYDEVELOPMENTCO.,LTD
RFWireless Remote Control RadioController/ Transmitter& Receiver
PackageInclude:
1xReceiver: S2U-DC06 / S2U-DC09 / S2U-DC12 / S2U-DC24 (2 Channel/ FourControlMode)
2xTransmitter: C-2L
1xUser manual
Feature:
Wireless control,easy toinstall
ControlLights,Motors,Fans, electricallyoperated Doors /Locks/Windows / Blinds/Cars or Other ApplianceswithAC110~240V orDC0~28V.
You can turn on/off thereceiver withtransmitter(remotecontrol)fromanyplacewithinareliabledistance;the wirelessRFsignalcanpass
through walls, floorsand doors.
Withcharacteristics of reversepower protection and over currentprotection
Audible/ visualindication
Usemicrocontroller modelof EM78P156, an 8-bitmicroprocessor designed and developed withlow-power and high-speed CMOS technology.
More reliablethan fixed code;the transmitter useEV1527 Learning code,whichisup to1million codes,reducing code collision and unauthorized
code scanning possibilities.
One/severaltransmitterscan controlone/severalreceiverssimultaneously.
Twoor more transmitter&receiverssetcanbe used inthe sameplace.
Transmitting Frequency: 315MHz /433MHz
Receiver:
ModelNo.: S2U-DC06 / S2U-DC09 / S2U-DC12 / S2U-DC24
Channel: 2CH
ControlModes: Toggle, Momentary, Latched, Momentary+Toggle
Coding Type: Fixed code or Learning code
Coding Setting:Bylearning
Power Supply(Operating Voltage): DC6V(S2U-DC06), DC12V 1V (S2U-DC12), DC9V 1V(S2U-DC09), DC24V 1V (S2U-DC24)
Working Voltage Range of Relay:AC110~240V or DC0~28V
PCBsize:67mm x50mm x18mm
Casesize: 75mm x54mm x27mm
StaticCurrent: ≤6mA
MaximumWorkingCurrent: 10A/ eachchannel
Transmitter:
ModelNo.: C-2L
Channel: 2CH
RemoteControlDistance: 100m/ 300ft (theoretically)
Encode:EV1527 Learning code (upto1million codes, reducing code collisionand unauthorized code scanningpossibilities.)
Unitsize: 58mm x39mm x16mm
Power Supply: 1x23A-12V battery(included,canbe usedfor 12months)
Usage:
Setting differentcontrolmodes(We havesetthe receiver asTogglecontrolmode before delivery.Ifyou wanttouseother controlmodes,do as
following operation):
Setting controlmode Toggle:Only connect Jumper-2.
Controlmode Toggle:Press ->On; Press again->Off.
Press button 1:Turn on relay1(connect B andC, disconnectAand B)
Press button 1again: Turn off relay1(disconnectB and C,connectAand B)
Press button 2:Turn on relay2(connect B andC, disconnectAand B)
Press button 2again: Turn off relay2(disconnectB and C,connectAand B)
Setting controlmode Momentary:OnlyconnectJumper-1.
Controlmode Momentary: Pressand hold->On; Release->Off.
Press and holdbutton 1:Turn on relay1(connectB andC, disconnectAand B)
Releasebutton 1:Turn off relay1(disconnectBand C,connect AandB)
Press and holdbutton 2:Turn on relay2(connectB andC, disconnectAand B)
Releasebutton 2:Turn off relay2(disconnectBand C,connect AandB)
Setting controlmode Latched:Disconnect Jumper-1 and Jumper-2.
Controlmode Latched:Press ->On, another relayOff;Press another button->Off.
Press button 1:Turn on relay1(connect B andC, disconnectAand B)
Turn off relay2(disconnectB andC, connectAand B)
Press button 2:Turn on relay2(connect B andC, disconnectAand B)
Turn off relay1(disconnectB andC, connectAand B)
Setting controlmode Momentary+Toggle: ConnectJumper-1 and Jumper-2.