[email protected] 1300 074 625 shockwatch.com.au May 2022
1. If the data logger has not been
stored at room temperature, place
it in room temperature for 30 mins
before starting.
2. Press and hold the START/STOP
button for approximately 5 seconds.
The green light ashes for 5 secs.
3. Place the data logger into
the location to be monitored.
Recording will begin after the start
delay period shown on the logger.
4. If there has been no temperature
excursion, the green light will
ash green every 10 seconds.
If a temperature excursion has
occurred, the red light will ash
every 10 seconds.
5. To stop recording, press and hold
the START/STOP button for 5
seconds. The red light ashes for 5
secs.
6. To generate a trip report, tear or cut
away the waterproof plastic bag. Be
careful not to damage the device
when cutting away the bag. Insert
the logger into a PC USB port. The
green and red lights will alternately
ash when the PDF report is being
generated.
7. When the PDF report has been
generated, the green and red lights
will illuminate solid until the logger
is removed from the USB port.
RC-17 Temperature Data Logger
User Manual
STATUS LED INDICATION
Does not Start Red and green light ash simultaneously
Start-up Delay Red and green light blinks alternately once
Start - Normal Green light blinks once ( ashes 10 times every minute)
Start - Alarm Red light ashes once (ashes 10 times every minute)
Start - Mark Red and green light ash 3 times at the same time
Start - Mark overrun Red and green light ash 3 times alternately
Stop - Normal Green light ashes twice
Stop - Alarm Red light ashes twice
OPERATION ACTION LED INDICATION
START Recording Press the START/STOP Button for 5 seconds The RECORD LED will blink 5 times
STOP Recording Press the START/STOP Button for 5 seconds The STATUS LED will blink 5 times
Status Indication
The status of the recording can be analyzed by the unit’s indicator light.
[email protected] 1300 074 625 shockwatch.com.au May 2022
Waterproof Plastic
Wrap
USB Port
LED Indicators
Button (Start/Status/
Mark/Stop)
Barcode Label
Conguration Info
Front Back
Start/Stop Info
Mark Info
Status Request
Paste Area
Temperature Measuring Range -30°C ~ +70°C
Resolution 0.1°C
Accuracy ±0.5°C (@-20°C~+40); 1°C/(@others)
Memory Capacity 16000 readings
Recording Period 6, 15, 30, 60, 90, 120, 180 days (customisable)
Alarm Type single or cumulative
Report Type PDF format
Data Interface USB2.0
Sensor type Internal NTC
Power supply Built-in CR2450 wide temperature lithium battery
Battery life 2 years (stored and used under normal temperature environment)
Protection grade IP67
Dimension 93mm (L) x 58mm (W) x 8mm (H)
Weight 20g
Specications
Log and Start Delay info
[email protected] 1300 074 625 shockwatch.com.au May 2022
Report Content
Download Data
Press the STOP button for
5 secs to stop logging.
The red light ashes 5
times.
Take the logger out of the
waterproof bag
Press the device into the
computers USB port to
view the PDF data report.

Other ShockWatch Data Logger manuals

ShockWatch Trekview User manual

ShockWatch

ShockWatch Trekview User manual

ShockWatch RC-17N User manual

ShockWatch

ShockWatch RC-17N User manual

Popular Data Logger manuals by other brands

NexSens X2-SDLMC quick start guide

NexSens

NexSens X2-SDLMC quick start guide

red lion Data Station Plus manual

red lion

red lion Data Station Plus manual

Hobo RXMOD-RXW Series quick start guide

Hobo

Hobo RXMOD-RXW Series quick start guide

Rotronic rotronic instruction manual

Rotronic

Rotronic rotronic instruction manual

IBA ibaDAQ-C manual

IBA

IBA ibaDAQ-C manual

MadgeTech HiTemp140X2 Series Product user guide

MadgeTech

MadgeTech HiTemp140X2 Series Product user guide

Mikster LGRT-02 user manual

Mikster

Mikster LGRT-02 user manual

Kilowatt Labs SIRIUS 1364-24-B-1C-TM-SD-A-G user manual

Kilowatt Labs

Kilowatt Labs SIRIUS 1364-24-B-1C-TM-SD-A-G user manual

Race Result Chip2Go Quick reference guide

Race Result

Race Result Chip2Go Quick reference guide

Kvaser Memorator Light HS v2 user guide

Kvaser

Kvaser Memorator Light HS v2 user guide

Racelogic Performance Box Touch V1 manual

Racelogic

Racelogic Performance Box Touch V1 manual

SEF 570.77A Quick reference guide

SEF

SEF 570.77A Quick reference guide

Eletech LogMaster-800 user manual

Eletech

Eletech LogMaster-800 user manual

LogTag Recorders UTRED30-16 Product user guide

LogTag Recorders

LogTag Recorders UTRED30-16 Product user guide

Logicbus RTDTemp101A Product user guide

Logicbus

Logicbus RTDTemp101A Product user guide

Capetti Elettronica WineCap WSD15IIDIST user manual

Capetti Elettronica

Capetti Elettronica WineCap WSD15IIDIST user manual

MONARCH INSTRUMENT TRACK-IT quick start guide

MONARCH INSTRUMENT

MONARCH INSTRUMENT TRACK-IT quick start guide

Onset HOBO user guide

Onset

Onset HOBO user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.