Shure AXIENT AXT630 User manual

© 2013 Shure Incorporated
27A21071 (Rev. 1)
Printed in USA
AXT630/AXT631/AXT632 Antenna Distribution System
Distributeur d’antenne AXT630/AXT631/AXT632
Sistemas de distribución de antenas AXT630/AXT631/AXT632
Sistemas de Distribuição de Antena AXT630/AXT631/AXT632

IMPORTANT SAFETY INSTRUCTIONS
1. READ these instructions.
2. KEEP these instructions.
3. HEED all warnings.
4. FOLLOW all instructions.
5. DO NOT use this apparatus near water.
6. CLEAN ONLY with dry cloth.
7. DO NOT block any ventilation openings. Allow sufficient distances for adequate ventila-
tion and install in accordance with the manufacturer’s instructions.
8. DO NOT install near any heat sources such as open flames, radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat. Do not place any open
flame sources on the product.
9. DO NOT defeat the safety purpose of the polarized or groundingtype plug. A polarized
plug has two blades with one wider than the other. A grounding type plug has two blades
and a third grounding prong. The wider blade or the third prong are provided for your
safety. If the provided plug does not fit into your outlet, consult an electrician for replace-
ment of the obsolete outlet.
10. PROTECT the power cord from being walked on or pinched, particularly at plugs, conve-
nience receptacles, and the point where they exit from the apparatus.
11. ONLY USE attachments/accessories specified by the manufacturer.
12. USE only with a cart, stand, tripod, bracket, or table specified by the manu-
facturer, or sold with the apparatus. When a cart is used, use caution when
moving the cart/apparatus combination to avoid injury from tip-over.
13. UNPLUG this apparatus during lightning storms or when unused for long
periods of time.
14. REFER all servicing to qualified service personnel. Servicing is required when the ap-
paratus has been damaged in any way, such as power supply cord or plug is damaged,
liquid has been spilled or objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been dropped.
15. DO NOT expose the apparatus to dripping and splashing. DO NOT put objects filled with
liquids, such as vases, on the apparatus.
16. The MAINS plug or an appliance coupler shall remain readily operable.
17. The airborne noise of the Apparatus does not exceed 70dB (A).
18. Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a
protective earthing connection.
19. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or
moisture.
20. Do not attempt to modify this product. Doing so could result in personal injury and/or
product failure.
21. Operate this product within its specified operating temperature range.
This symbol indicates that dangerous voltage constituting a risk of
electric shock is present within this unit.
This symbol indicates that there are important operating and mainte-
nance instructions in the literature accompanying this unit.
WARNING: This product contains a chemical known to the State of California to cause cancer and birth
defects or other reproductive harm.
CONSIGNES DE SÉCURITÉ IMPORTANTES
1. LIRE ces consignes.
2. CONSERVER ces consignes.
3. OBSERVER tous les avertissements.
4. SUIVRE toutes les consignes.
5. NE PAS utiliser cet appareil à proximité de l'eau.
6. NETTOYER UNIQUEMENT avec un chiffon sec.
7. NE PAS obstruer les ouvertures de ventilation. Laisser des distances suffisantes pour
permettre une ventilation adéquate et effectuer l'installation en respectant les instructions
du fabricant.
8. NE PAS installer à proximité d'une source de chaleur telle qu'une flamme nue, un
radiateur, une bouche de chaleur, un poêle ou d'autres appareils (dont les amplificateurs)
produisant de la chaleur. Ne placer aucune source à flamme nue sur le produit.
9. NE PAS détériorer la sécurité de la fiche polarisée ou de la fiche de terre. Une fiche
polarisée comporte deux lames dont l'une est plus large que l'autre. Une fiche de terre
comporte deux lames et une troisième broche de mise à la terre. La lame la plus large ou
la troisième broche assure la sécurité de l'utilisateur. Si la fiche fournie ne s'adapte pas à
la prise électrique, demander à un électricien de remplacer la prise hors normes.
10. PROTÉGER le cordon d'alimentation afin que personne ne marche dessus et que rien ne
le pince, en particulier au niveau des fiches, des prises de courant et du point de sortie
de l'appareil.
11. UTILISER UNIQUEMENT les accessoires spécifiés par le fabricant.
12. UTILISER uniquement avec un chariot, un pied, un trépied, un support ou
une table spécifié par le fabricant ou vendu avec l'appareil. Si un chariot
est utilisé, déplacer l'ensemble chariot-appareil avec précaution afin de ne
pas le renverser, ce qui pourrait entraîner des blessures.
13. DÉBRANCHER l'appareil pendant les orages ou quand il ne sera pas utilisé pendant
longtemps.
14. CONFIER toute réparation à du personnel qualifié. Des réparations sont nécessaires
si l'appareil est endommagé d'une façon quelconque, par exemple : cordon ou prise
d'alimentation endommagé, liquide renversé ou objet tombé à l'intérieur de l'appareil,
exposition de l'appareil à la pluie ou à l'humidité, appareil qui ne marche pas normale-
ment ou que l'on a fait tomber.
15. NE PAS exposer cet appareil aux égouttures et aux éclaboussements. NE PAS poser
des objets contenant de l'eau, comme des vases, sur l'appareil.
16. La prise SECTEUR ou un coupleur d’appareil électrique doit rester facilement utilisable.
17. Le bruit aérien de l'appareil ne dépasse pas 70 dB (A).
18. L'appareil de construction de CLASSE I doit être raccordé à une prise SECTEUR dotée
d'une protection par mise à la terre.
19. Pour réduire les risques d'incendie ou de choc électrique, ne pas exposer cet appareil à
la pluie ou à l'humidité.
20. Ne pas essayer de modifier ce produit. Cela risque de causer des blessures et/ou la
défaillance du produit.
21. Utiliser ce produit dans sa plage de températures de fonctionnement spécifiée.
Ce symbole indique la présence d'une tension dangereuse dans
l'appareil constituant un risque de choc électrique.
Ce symbole indique que la documentation fournie avec l'appareil con-
tient des instructions d'utilisation et d'entretien importantes.
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
1. LEA estas instrucciones.
2. CONSERVE estas instrucciones.
3. PRESTE ATENCION a todas las advertencias.
4. SIGA todas las instrucciones.
5. NO utilice este aparato cerca del agua.
6. LIMPIE UNICAMENTE con un trapo seco.
7. NO obstruya ninguna de las aberturas de ventilación. Deje espacio suficiente para
proporcionar ventilación adecuada e instale los equipos según las instrucciones del
fabricante.
8. NO instale el aparato cerca de fuentes de calor tales como llamas descubiertas, radiad-
ores, registros de calefacción, estufas u otros aparatos (incluyendo amplificadores) que
produzcan calor. No coloque artículos con llamas descubiertas en el producto.
9. NO anule la función de seguridad del enchufe polarizado o con clavija de puesta a tierra.
Un enchufe polarizado tiene dos patas, una más ancha que la otra. Un enchufe con pu-
esta a tierra tiene dos patas y una tercera clavija con puesta a tierra. La pata más ancha
o la tercera clavija se proporciona para su seguridad. Si el tomacorriente no es del tipo
apropiado para el enchufe, consulte a un electricista para que sustituya el tomacorriente
de estilo anticuado.
10. PROTEJA el cable eléctrico para evitar que personas lo pisen o estrujen, particularmente
en sus enchufes, en los tomacorrientes y en el punto en el cual sale del aparato.
11. UTILICE únicamente los accesorios especificados por el fabricante.
12. UTILICE únicamente con un carro, pedestal, trípode, escuadra o mesa del
tipo especificado por el fabricante o vendido con el aparato. Si se usa un
carro, el mismo debe moverse con sumo cuidado para evitar que se vuelque
con el aparato.
13. DESENCHUFE el aparato durante las tormentas eléctricas, o si no va a ser utilizado por
un lapso prolongado.
14. TODA reparación debe ser llevada a cabo por técnicos calificados. El aparato requiere
reparación si ha sufrido cualquier tipo de daño, incluyendo los daños al cordón o enchufe
eléctrico, si se derrama líquido sobre el aparato o si caen objetos en su interior, si ha sido
expuesto a la lluvia o la humedad, si no funciona de modo normal, o si se ha caído.
15. NO exponga este aparato a chorros o salpicaduras de líquidos. NO coloque objetos
llenos con líquido, tales como floreros, sobre el aparato.
16. El enchufe de alimentación o un acoplador para otros aparatos deberá permanecer en
buenas condiciones de funcionamiento.
17. El nivel de ruido transmitido por el aire del aparato no excede de 70 dB(A).
18. Los aparatos de fabricación CLASE I deberán conectarse a un tomacorriente de ALI-
MENTACION con clavija de puesta a tierra protectora.
19. Para reducir el riesgo de causar un incendio o sacudidas eléctricas, no exponga este
aparato a la lluvia ni a humedad.
20. No intente modificar este producto. Hacerlo podría causar lesiones personales y/o la falla
del producto.
21. Utilice este producto únicamente dentro de la gama de temperaturas de funcionamiento
especificadas.
Este símbolo indica que la unidad contiene niveles de voltaje peligrosos
que representan un riesgo de choques eléctricos.
Este símbolo indica que la literatura que acompaña a esta unidad con-
tiene instrucciones importantes de funcionamiento y mantenimiento.

IMPORTANTES INSTRUÇÕES DE SEGURANÇA
1. LEIA estas instruções.
2. GUARDE estas instruções.
3. PRESTE ATENÇÃO a todas as instruções.
4. SIGA todas as instruções.
5. NÃO use este aparelho perto de água.
6. LIMPE SOMENTE com um pano seco.
7. NÃO bloqueie nenhuma das aberturas de ventilação. Deixe distâncias suficientes para
ventilação adequada e instale de acordo com as instruções do fabricante.
8. NÃO instale próximo de nenhuma fonte de calor, tais como fogo aceso, radiadores,
bocais de aquecimento, fornos ou outros aparelhos que produzam calor (inclusive ampli-
ficadores). Não coloque fontes de chamas sobre o produto.
9. NÃO inutilize as características de segurança do conector polarizado ou com pino de
aterramento. Um conector polarizado possui duas lâminas com uma mais larga do que a
outra. Um conector com pino de aterramento possui duas lâminas e um terceiro pino de
aterramento. É fornecida uma lâmina mais larga ou o terceiro pino para a sua segurança.
Se por acaso o conector não se encaixar na tomada, chame um eletricista para substituir
a tomada obsoleta.
10. PROTEJA o cabo de alimentação, evitando que seja pisado ou que enrosque, especial-
mente nos conectores, nas tomadas elétricas de emprego geral e no ponto onde elas
saem do aparelho.
11. USE SOMENTE acessórios/apetrechos especificados pelo fabricante.
12. USE somente com um carrinho, pedestal, tripé, suporte ou mesa espe-
cificados pelo fabricante ou vendidos com o aparelho. Quando utilizar um
carrinho, tenha cuidado ao movimentar o conjunto aparelho/carrinho para
evitar danos com a queda do mesmo.
13. DESLIGUE este aparelho da tomada elétrica durante tempestades com relâmpagos ou
quando não seja utilizado por longo período.
14. DEIXE toda a manutenção sob a responsabilidade de uma equipe de manutenção
qualificada. É necessário realizar a manutenção quando por algum motivo o aparelho
tiver sido danificado de alguma forma, como por exemplo por dano do cabo de alimen-
tação elétrica ou do seu conector, por derramamento de líquido ou queda de objetos no
aparelho, se o aparelho tiver sido exposto à chuva ou à umidade, não esteja operando
normalmente ou tenha sofrido queda.
15. NÃO exponha o aparelho a respingos ou goteiras. NÃO coloque objetos cheios de
líquidos, tais como vasos, sobre o aparelho.
16. O plugue MAINS (rede elétrica) ou um acoplador de aparelho deve estar sempre pronto
para operação.
17. O ruído aéreo do Aparelho não ultrapassa 70 dB (A).
18. O aparelho com construção CLASSE I deve estar conectado à tomada da rede elétrica
com ligação à terra.
19. Para reduzir o risco de incêndio ou choque elétrico, não exponha este aparelho à chuva
ou umidade.
20. Não tente alterar este produto. Isso poderá resultar em lesão pessoal e/ou falha do
produto.
21. Opere este produto dentro da faixa de temperatura de operação especificada.
Este símbolo indica que existe nesta unidade tensão perigosa que
apresenta risco de choque elétrico.
Este símbolo indica que existem instruções operação e manutenção
importantes na literatura que acompanha esta unidade.


1
AXT630, AXT631 and AXT632 Antenna Distribution Systems
Antenna Distribution Systems send the RF signal from a single pair of antennas to multiple receivers. Ultra-linear amplification and adjustable attenuation
optimize performance in difficult RF environments. Selectable input filters match the available frequency bands of transmitters, providing extra protection
from strong out-of-band signals. BNC antenna output pairs distribute band-filtered signals to up to 4 receivers. A pair of wideband cascade ports supply wide-
band RF signals to Spectrum Managers or additional antenna distribution amplifiers. Networking allows Wireless Workbench to control filtering ranges and
attenuation.
To maximize use of the RF spectrum, Antenna Distribution Systems are available in the following frequency ranges:
• AXT630 (470-698 MHz)
• AXT631 (606-814 MHz)
• AXT632 (470–787 MHz)
Note:Instructions in the system guide apply all models of Antenna Distributions Systems in this guide.
Mounting Instructions
This component is designed to fit into an audio rack.
WARNING: To prevent injury this apparatus must be securely attached to the rack.
Features
• Selectable input filtering provides system-wide protection against strong out-of-band signals
• Wideband filtering option covers multiple bands
• Up to 15 dB of selectable RF attenuation for signal-to-noise optimization
• Front panel interface and Wireless Workbench 6 software control provide easy setup and control of filtering, antenna power, and attenuation
• BNC outputs: 4 antenna output pairs
• Wideband RF cascade port with selectable 3 dB make-up gain for connecting wideband devices
• Ethernet Networking: 2 PoE enabled Ethernet ports
• IEC power ports enable daisy-chaining of AC power
Optional Accessories
Antennas
Passive Omnidirectional
Antenna (470-1100 MHz)
UA860SWB
Passive Directional
Antenna (470-952 MHz)
PA805SWB
PWS Helical Antenna
(480-900 MHz)
HA-8089
In-Line RF Amplifiers
(470-900 MHz) UA830WB
(470-698 MHz) UA830USTV
Active Directional Antennas
470-698 MHz UA874US
470-790 MHz UA874E
470-900 MHz UA874WB
925-952 MHz UA874X
Included Components
2-foot Coaxial Antenna Cable (RG-58) (12) UA802
IEC AC Power Cable (1) 95A9128
IEC AC Extension Cable (1) 95A9129
Shielded 3-foot Ethernet Cable (1) C803
Shielded 8-inch Ethernet Jumper Cable (1) C8006
Hardware Kit (1) 90XN1371
22-inch Coaxial Cable* (1) 95B9023
33-inch Coaxial Cable* (1) 95C9023
*with integrated bulkhead for front mounting antennas.
1/2 Wave Antennas
(744-865 MHz) UA820G
(690-746 MHz) UA820H4
(554-590 MHz) UA820J
(606-666 MHz) UA820K
(638-698 MHz) UA820L3
(694-758 MHz) UA820M
(740-814 MHz) UA820Q
(710-790 MHz) UA820P8
Cables
25-foot Coaxial
Cable RG8/X
UA825
50-foot Coaxial
Cable RG8/X
UA850
100-foot (30.4 m)
Antenna Extension
Cable
UA8100

2
① LCD Display
Displays menu and settings.
② Navigation Buttons
• Arrows: Scroll menus and change settings
• SET: Enables menu edits and saves changes
③ Power Switch
Powers the unit on or off
④ AC Power Primary Switch
AC Main Power Switch
⑤ AC Power In
IEC Connector, 100-240 V AC
⑥ AC Power Cascade
Use the IEC extension cables to connect up to 5 devices to a single AC
power source.
⑦ Network Speed LED (amber):
• Off = 10 Mbps
• On = 100 Mbps
⑧ Ethernet Ports (2)
PoE Class 1 enabled. Connect to an Ethernet network to enable remote
control and monitoring
power
SET
2 3
1
AXT631
606-814 MHz
Antenna Distribution
Amplier
antenna
in
B A
45 6
8
7 9
10 11
12
14
13
AXT631
4B 3B 2B 1B
RF outputs
4A 3A 2A 1A
RF outputs
PoE Class 1
Controls and Connectors
⑨ Network status LED (green)
• Off = no network link
• On = network link active
• Flashing = network link active, flash rate corresponds to traffic
volume
⑩ RF Output Connectors, Channel B
Distributes RF signal for Channel B
⑪ RF Output Connectors, Channel A
Distributes RF signal for Channel A
⑫ Antenna IN Ports, Channels A and B
Antenna inputs are DC biased for use with active antennas or in-line
amplifiers.
⑬ RF Cascade Ports, Channels A and B
Passes the wideband RF signal from one device to the next, allowing up
to 5 devices to share a single pair of antennas.
⑭ Antenna Input Status LED
• Green = DC power on
• Off = DC power off
• Red = Antenna fault or over-current condition

3
Antennas
The Antenna Distribution Systems are compatible with front-mounted antennas or with remote-mounted antennas.
Note: When using the input band filtering function, select an antenna with bandwidth to cover the filter range.
antenna
in
cascade
out
12.7V OUT
150 mA
B A
4B 3B 2B 1B
RF outputs
4A 3A 2A 1A
RF outputs
antenna
in
cascade
out
12.7V OUT
150 mA
B A
4B 3B 2B 1B
RF outputs
4A 3A 2A 1A
RF outputs
antenna
in
cascade
out
12.7V OUT
150 mA
B A
4B 3B 2B 1B
RF outputs
4A 3A 2A 1A
RF outputs
antenna
in
cascade
out
12.7V OUT
150 mA
B A
antenna
in
cascade
out
12.7V OUT
150mA
B A
4B 3B 2B 1B
RF outputs
4A 3A 2A 1A
RF outputs
antenna
in
cascade
out
12.7V OUT
150mA
B A
Installing Front-mounted Antennas
Mounting the antennas on the front panel improves system performance by providing a clear signal path for the RF signal. Use the supplied bulkhead adapter
kit to install the antennas on the front panel.
1. Insert the bulkhead adapters on the supplied front-mounting cables through the holes in each bracket and secure them from the front using the supplied
hardware.
2. Connect the supplied antennas cables to the antenna input BNC connectors.
3. Install the antenna onto the bulkhead adapters.
Note: To minimize the possibility of signal dropout and optimize performance, point the antennas up and away from each other at 45° from vertical.
Installing Remote Antennas
Remote antennas offer greater flexibility for antenna placements and can improve performance by providing a less obstructed transmission path and extend-
ing range. Consult http://www.shure.com for tips and best practices for remote mounting antennas.
RF Output Distribution
Input Band Filtering
The input band filters act on the RF distribution ports but do not affect the
RF cascade ports. The Wideband setting passes the full frequency range
of the Antenna Distribution System. Select the band filter that most closely
matches the tuning range of connected devices to optimize performance.
When a band filter has been set, operate and tune connected devices within the selected band.
Gain and Attenuation
Use the RF Gain menu to maintain consistent signal levels sent to con-
nected devices. The available adjustment range is -12 to +3 dB when the
Cascade ports are off and -15 to 0 dB when the cascade ports are active.
RF Cascade Ports
The RF cascade ports extend the Antenna Distribution System by providing
a connection point for additional receivers, Spectrum Managers, or Antenna
Distribution Systems.
When Antenna Cascade is set to Auto, the Cascade ports automatically acti-
vate when 12 V DC from the antenna input of a connected device is sensed
at the port connection. When the cascade ports are active, a signal splitting
loss occurs of 5 dB (max.).
Receivers with RF cascade outputs can extend the antenna signal to addi-
tional receivers within the same band.
Adding an AXT600 Spectrum Manager to
an Antenna System
Connect the AXT600 Spectrum Manager to the RF Cascade ports of the
Antenna Distribution System.
The RF outputs distribute the signal from a pair of antennas to up to 4
receivers or additional antenna distribution systems. Port-to-port isolation
reduces interference, making the distribution ports the best option for distrib-
uting signal to additional devices.
Connecting Devices
Connect an A and B pair of RF outputs from the Antenna System to the A
and B inputs of the device.

4
Main Menu
Use the main menu to select the band filter, adjust the RF gain, and configure the antenna ports.
Band
Selecting an input Band filter optimizes performance when the compo-
nents connected to the RF outputs are all within the same band. The
selected band filter will only pass frequencies within the range of the
connected components. Four selectable input filters are available to
match the frequency bands transmitters and receivers. A Wideband
setting is available to extend frequency support across all 4 bands.
This setting allows receivers operating in a variety of bands to use the
RF outputs.
To set the Band filter:
1. Navigate to the Band menu and press the SET button to enable
editing.
2. Use the arrows to select a band filter or to select the Wideband
setting.
3. Press the SET button to save changes.
RF Gain
Adjust the RF gain to boost or attenuate the antenna signal to maintain
consistent levels and prevent overload. Gain adjustments are made in
1 dB increments.
The gain adjustment range depends on the connection status of the
RF cascade ports:
• Cascade ports connected: adjustment range = -15 dB to 0 dB
• Cascade ports not connected: adjustment range = -12 dB to +3 dB
Antenna Cascade
Auto
The ports will activate when a connected device supplies 12-15 V DC to the
port.
On
The ports are continuously active, independent of voltage applied by a
connected device.
Antenna Power
ON
The antenna ports supply 12-15 V DC to power active antennas.
OFF
Turns off DC voltage at the antenna ports.
Network Status
Active
Indicates connectivity with other devices on the network.
Inactive
No connectivity with other devices on the network.
Note: IP address must be valid to enable networked control.
AXT630 (Wideband)
AXT600
AXT630 (H4 Filtered)AXT630 (G1 Filtered)
Receiver (G1)
Receiver (G1)
Receiver (G1)
Receiver (G1)
Receiver (H4)
Receiver (H4)
Receiver (H4)
Receiver (H4)
RF Outputs
Cascade Ports
SET
Antenna
Fault
SET
Over
Temperature
Multiple Levels of Antenna Distribution
For large configurations, multiple Antenna Distribution Systems can be layered to support several levels of signal distribution:
• Two levels of antenna distribution are possible if the level 1 and level 2 Antenna Distribution Systems have the Cascade ports activated
• Up to 3 levels of antenna distribution are possible if only the level 1 Antenna Distribution System has the Cascade ports activated
• For best RF performance, use all the RF outputs on one level before creating additional levels
Level 1: Antenna
Distribution System set to
Wideband
Level 2: Antenna Distribution
System set to a band filter
matching the 4 receivers tuned
to the same band
Connect the AXT600 Spectrum
Manager to the RF cascade
ports of the Level 1 Antenna
Distribution System
Troubleshooting
Antenna Faults
The antenna input status LED flashes red to indicate a
short or over-current condition at an antenna port. To
isolate the fault, navigate to the DC power menu. The
menu displays which antenna port (A, B, or A+B) is the
source of the fault. Check the antenna connections to
remove the fault condition.
Over Temperature Message
The Over Temperature message is displayed when
the fans are unable to cool efficiently, indicating an el-
evated temperature condition.
• Press any button to suppress the message for 20
seconds
• Increase ventilation to the unit to clear the message

5
Utility Menu
Press and hold both arrow keys to enter and exit the utility menu, which is used to access network and display settings.
hold both arrow keys
IP Address Mode:
Automatic
This is the default setting for use with a DHCP
server, which automatically assigns an IP
address.
1. Navigate to the IP Mode menu and press the
SET key.
2. Use the arrow keys to highlight Automatic.
3. Press the SET key.
4. Use the arrow keys to move the ► to select
MAC (MAC Address)
Displays the MAC address, which is an embed-
ded, uneditable identification number unique to
each device. Used by the network and WWB
software to identify components.
Device ID
This eight-character name is displayed when
this device is detected on other network de-
vices or in WWB software.
1. Press SET key to enable editing.
2. Use the arrow keys to change the
characters.
3. To finish editing, press the SET key until
none of the characters are highlighted.
OK to save or Cancel to discard, and then
press the SET key.
IP Address Mode: Manual
Use manual IP addressing to set the IP ad-
dress and subnet mask when a DHCP server is
not available.
1. Navigate to the IP mode menu and press the
SET key.
2. Use the arrow keys to highlight Manual.
3. Press the SET key to enable editing of the IP
address and the subnet mask.
4. Use the arrow keys to move the ► to select
IP: or Sub:
5. Use the arrow keys and the SET key to edit
the IP address and subnet mask.
6. Use the arrow keys to move the ► to select
OK to save or Cancel to discard, and then
press the SET key.
SET
Serial Number
Displays the serial number.
Firmware
Displays the version of firmware installed on
this device.
Brightness
Sets the brightness of the LCD to low, medium,
or high.
Display Invert
This changes the LCD menu from white text
on dark background to dark text on a light
background.
Front Panel Lock
Locks or unlocks the navigation buttons to
prevent accidental or unauthorized changes to
settings.
On
Locks the navigation buttons.
Off
Unlocks the navigation buttons.
Power Switch Lock
Lock the power switch to ensure that power is
not accidentally turned off.
On
Locks the power switch.
Off
Unlocks the power switch.
Fan (Cooling Fan Mode)
Automatic
The fan is enabled and adjusts speed based
on the internal temperature of the unit.
Always on
The fan runs continuously at maximum
speed to provide maximum cooling in warm
environments.
Firmware Updates
Firmware is embedded software in each compo-
nent that controls functionality. Periodically, new
versions of firmware are developed to incorpo-
rate additional features and enhancements. To
take advantage of design improvements, new
versions of the firmware can be uploaded and in-
stalled using the Firmware Update Manager tool
available in WWB6 software. Firmware is avail-
able for download from http://www.shure.com.

6
Specifications -- AXT630, AXT631, AXT632
Dimensions
44 mm x 483 mm x 366 mm (1.7 in. x 19.0 in. x 14.4 in.), H x W x D
Weight
4.6 kg (10.1 lbs),
Housing
Steel; Extruded aluminum
Operating Temperature Range
-18°C (0°F) to 63°C (145°F)
Storage Temperature Range
-29°C (-20°F) to 74°C (165°F)
Power Requirements
100 to 240 V AC, 50-60 Hz
Current Drain
1.0 A RMS (referenced at 120 V AC)
RF Input
Connector Type
BNC
Configuration
Unbalanced, active
Band Filters
AXT630 Wideband 470–698 MHz
Band G1 470–530 MHz
Band H4 518–578 MHz
Band J5 578–638 MHz
Band L3 638–698 MHz
AXT631 Wideband 606–814 MHz
Band K4E 606–666 MHz
Band M8 666–730 MHz
Band P8, P9 710–790 MHz
Band Q5 740–814 MHz
AXT632 Wideband 470–787 MHz
Band G7C 470–510 MHz
Band L3E 638–698 MHz
Band M8 666–730 MHz
Band P9 710–787 MHz
Impedance
50 Ω
Bias Voltage
12 V DC, 150 mA (300 mA maximum)
RF Frequency Range
AXT 630 470–698 MHz
AXT 631 606–814 MHz
AXT 632 470–787 MHz
Distribution Output
Connector Type
BNC (4 pairs)
Configuration
Unbalanced, active
Impedance
50 Ω
Gain Adjustment Range
Cascade Enabled -15 dB to 0 dB (In 1 dB steps)
Cascade Disabled -12 dB to +3 dB (In 1 dB steps)
Output Intercept Point
>25 dBm, typical
Cascade Output
Connector Type
BNC (1 pair)
Configuration
Unbalanced, wideband
Impedance
50 Ω
Insertion Loss
<5 dB

7
(Cascade Bypass)
() Denotes gain when cascade is disabled
Passive Splitter
-3.5 dB
-3.5 dB0 dB
50 Ω50 Ω
-15 dB to 0 dB
(-12 dB to +3 dB)
-15 dB to 0 dB
(-12 dB to +3 dB)
50 Ω
Passive Splitter
50 Ω
-15 dB to 0 dB
(-12 dB to +3 dB)
-15 dB to 0 dB
(-12 dB to +3 dB)
Passive Splitter
User Gain Adjust
50 Ω50 Ω
Antenna In Cascade Out Distro Out 1 Distro Out 4Distro Out 3Distro Out 2
Filter Select Switch
Filter Select Switch
Filter 4
Wide Band
Filter 3
Filter 2
Filter 1
Passive Splitter
AXT 630/ AXT631 Circuit Diagram
AXT630/AXT631/AXT632 Circuit Diagram
Certifications
AXT630, AXT631, and AXT632
Meets essential requirements of the following European Directives:
• R&TTE Directive 99/5/EC
• Conforms to European Regulation (EC) No. 1275/2008, as amended.
• WEEE Directive 2002/96/EC, as amended by 2008/34/EC
• RoHS Directive 2002/95/EC, as amended by 2008/35/EC
Note: Please follow your regional recycling scheme for batteries and electronic waste
Meets requirements of the following standards: EN 300 422 Parts 1 and 2, EN 301 489 Parts 1 and 9, EN60065.
EN 300 422 Parts 1 and 2. EN 301 489 Parts 1 and 9. EN60065.
AXT630
Approved under the Declaration of Conformity (DoC) provision of FCC Part 15.
Meets Industry Canada RSS-123.
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
This device complies with Industry Canada license-exempt RSS standard(s).
Information to the user
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television recep-
tion, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Note: EMC conformance testing is based on the use of supplied and recommended cable types. The use of other cable types may degrade EMC performance.
Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
The CE Declaration of Conformity can be obtained from Shure Incorporated or any of its European representatives. For contact information please visit www.
shure.com
The CE Declaration of Conformity can be obtained from: www.shure.com/europe/compliance
Authorized European representative:
Shure Europe GmbH
Headquarters Europe, Middle East & Africa
Department: EMEA Approval
Jakob-Dieffenbacher-Str. 12
75031 Eppingen, Germany
Phone: 49-7262-92 49 0
Fax: 49-7262-92 49 11 4
Email: [email protected]

www.shure.com
©2013 Shure Incorporated
Asia, Pacific:
Shure Asia Limited
22/F, 625 King’s Road
North Point, Island East
Hong Kong
Phone: 852-2893-4290
Fax: 852-2893-4055
Email: [email protected]
United States, Canada, Latin
America, Caribbean:
Shure Incorporated
5800 West Touhy Avenue
Niles, IL 60714-4608 USA
Phone: 847-600-2000
Fax: 847-600-1212 (USA)
Fax: 847-600-6446
Email: [email protected]
Europe, Middle East, Africa:
Shure Europe GmbH
Jakob-Dieffenbacher-Str. 12,
75031 Eppingen, Germany
Phone: 49-7262-92490
Fax: 49-7262-9249114
Email: [email protected]
Other manuals for AXIENT AXT630
4
This manual suits for next models
2
Table of contents
Other Shure Amplifier manuals

Shure
Shure M267 User manual

Shure
Shure Solo-Phone SA-1F User manual

Shure
Shure RK183PK User manual

Shure
Shure M64 User manual

Shure
Shure UA830 User manual

Shure
Shure SR10 Operation manual

Shure
Shure RK100PK User manual

Shure
Shure ILP-1 User manual

Shure
Shure SOLO-PHONE SA-1 User manual

Shure
Shure MX1BP User manual
Popular Amplifier manuals by other brands

Soundstream
Soundstream Reference Series CLASS-A-3.0 installation guide

Luxman
Luxman 5M20 Service manual

Hifonics
Hifonics Series VI Odin user guide

Advanced Visual Solutions
Advanced Visual Solutions AVSP340A Installation and operating instructions

VAC
VAC CPA1 Mk III instructions

Kenwood
Kenwood PL-922 instruction manual