Shure M267 User manual

GENERAL
The Shure Model M267 is a microphone mixer-remote
amplifier specifically designed for professional applications.
The excellent performance, versatility and features of this
complete, compact console make it an ideal choice for stu-
dio, remote, or sound reinforcement use, and as an add-on
mixer for expanding existing facilities. It is also ideally suited
for use with audio and video tape recorders to provide multi-
ple microphone inputs.
Features:
SWide, flat frequency response and extremely low dis-
tortion up to +18 dBm output
SExtremely low noise and RF susceptibility
SFour switchable microphone- or line-level balanced-line
inputs with individual gain controls and low-frequency
rolloffswitches. MUMETALshieldingoninputtransform-
ers
SFeedback-type input gain controls for maximum clip-
ping levels and dynamic range
SOutput switchable for line or microphone level
SBuilt-in switchable peak limiter cuts output overload
distortion, adapts to power supply voltage
SLEDindicatorshowslimiter operation oroverloadwith
limiter defeated
SExternallyadjustablelimiterthreshold(–4to+18dBm)
SVU meter calibrated for +4 and +8 dBm with range
switch. Illuminated with ac operation
SAc or built-in battery operation. Noiseless automatic
switchover to battery in case of ac line failure. Battery
test without program interruption
SFront-panel headphone level control and monitor jack
drivesalmostany stereoormonoheadphones;output
can be additional unbalanced line feed to drive a tape
recorder or power amplifier
SDirect mix bus for stacking units
SAutomatic muting prevents speaker damage during
turn-on and -off
SLowdistortion,high-stability tone oscillatorforlinetest
and level checks
SAll connections phased. Line output terminals phase-
indicated
SCompactandlightweight,withrugged,abrasion-resis-
tant case
SInternally selectable 120 or 240 Vac, 50/60 Hz opera-
tion
SUnderwriters’LaboratoriesListedandCanadianStan-
dards Association listed as Certified
SPECIFICATIONS
Frequency Response
30 Hz to 20,000 Hz, ±2 dB
Voltage Gain (at 1,000 Hz)
(Outputs terminated: line 600 W, microphone 150 W, mix
bus 3.3 kW, headphone 200 W, tip-sleeve and ring-
sleeve )
Inp t
OUTPUT
Input Line Microphone Mix
Bus
Low-Impedance
Microphone (150 Ω)91 dB 41 dB 24 dB
Line 40 dB –9 dB –27 dB
Mix Bus 55 dB 5 dB – –
Inputs
IMPEDANCE
Input
Designed
for Use
With
Actual
(Internal) Input
Clipping Level
Microphone 19 to
600 Ω1 kΩ–32 dBV to
–5 dBV∗
(25 mV to 0.56 V)
Line Less
than10 kΩ66 kΩ+20 dBV
Mix Bus 3.5 kΩ3.5 kΩ+7 dBV (2.2 V)
∗Depending on input control setting
Shure Brothers Incorporated
222 Hartrey Avenue
Evanston IL 60202-3696 U.S.A.
Model M267 User Guide
27A8376 (SE)
E1999, Shure Brothers Incorporated Printed in U.S.A.

2
Outputs
IMPEDANCE
Output Designed for
Use With Actual
(Internal) Output
Clipping Level
Microphone Any low imped-
ance microphone
input
0.5 –34 dB
(20 mV)
Mix Bus 3.5 kΩ3.5 kΩ–8 dBV
(400 mV)
Head-
phones 8 - 2000 Ω
200 Ω
recommended
400 Ωto
3 kΩ∗∗ +10 dBV
(3.3 V)
Line 600Ω150Ω+18 dBm
(6.2 V)
∗∗Depending on level control setting
Noise
EquivalentInputHum andNoise:–126dBV(lowim-
pedance microphone, 150 Ω- 20-20,000 Hz) into a
600 Ωload at full gain
Output Noise: –75 dBV (master control fully counter-
clockwise),–53 dBV(master fullyclockwise), (inputcon-
trols down, 300-20,000 Hz)
Output Hum and Noise: –70 dBV (master control
down), –51 dBV (master control up) (input controls
down, 20-20,000 Hz)
Distortion
0.35% or less THD from 30 to 20,000 Hz at +15 dBm
output; 0.5% or less IM distortion up to +15 dBm output
level
Common Mode Rejection
65 dB minimum with input of –20 dBV at 100 Hz
Control Interaction
Less than 1 dB with any control combination
Overload and Shorting Protection
Shorting the outputs, even for prolonged periods, will
cause no damage; microphone inputs will not be dam-
aged by signals up to 3 volts
Lo-Cut Filters
6 dB/octave rolloff at 150 Hz
Limiter
Threshold: +15 dBm (line output level; adjustable
from –4 to +18 dBm)
Attack Time: 3 msec typical
Recovery Time: 500 msec typical
Peak Indicator
Lights 6 dB below clipping or at onset of limiter action
Headphone Output Clipping Level
3.16V (+10 dBV) into 200 Ω
Tone Oscillator
1,000 Hz, 1.5% or less THD
Phantom Power
30 Vdc open-circuit, 3.3 kΩseries resistance, input
switches in MIC position only
Operating Voltage
Ac Operation: 120 or 240 volts ±10%, 50/60 Hz,
9.5W, internally switchable[
Dc Operation: 27 volts nominal at 15 mA typical no-
signal, 18 mA typical at 0 VU (+4 dBm) output with
headphone load; 21.5 volts minimum
Batterylife:approximately 20 hourswithalkalinebat-
teriesat+4 dBm outputincontinuous use; three9-volt
batteries, type NEDA 1604A (Duracell MN1604 rec-
ommended)
[ Suppliedwiredfor120Vacoperation(SeeServicesectionfor240
Vac operation)
Temperature Range
Operating: –18oto 57oC (0oto 135oF)
Storage: –29oto 71oC (–20oto 160oF)
Dimensions
See Figure 1
309 mm
(12 5/32 in.)
68.8mm
(2 23/32 in.)
6.3 mm
(1/4in. )
229 mm
(9 in.)
FIGURE 1
Weight
Net: 2.3 kg (5 lb 2 oz)
Packaged: 3.2 kg (7 lb 2 oz)
Certifications
Listed by Underwriters’ Laboratories, Inc., and listed by
Canadian Standards Association as Certified

3
CONTROLS AND CONNECTORS
WARNING
Thisapparatusmustbeearthed(grounded)! The
M267 power supply is energized when the unit is
connected to an ac source; disconnect mains
(power) plug from supply when not in use.
Inputs
The four inputs are professional three-pin female XLR
audioconnectorslocatedontherearpanelanddesignated
INPUT1throughINPUT4. Theinputsarebalanced(inter-
nal transformer, MUMETAL shielded); pins 2 and 3 are
“hot”,andpin1is“ground”. Formicrophoneoperation,the
switches labeled LINE/MIC (directly above the input con-
nectors) must be in the MIC position; for line level inputs,
theswitchesmustbeintheLINEposition. Forimpedance,
clipping and operating signal levels, refer to the SPECIFI-
CATIONS section.
Outputs
The rear-panel connector labeled OUTPUT is a profes-
sionalthree-pinmaleXLRaudioconnector. Withtheadja-
cent LINE/MIC switch in the MIC position, the OUTPUT
connector is used to feed a low-impedance microphone
lineoralow-impedancemicrophoneinput. With theLINE/
MIC switch in the LINE position, the OUTPUT connector
feeds the line-level input of an amplifier, tape recorder, or
anothermixer. TheOUTPUTconnectorisabalancedout-
put with the LINE/MIC switch in either position; pin 1 is
ground, pins 2 and 3 are “hot”, and the connector is in
phasewiththecorrespondingpinsoftheinputconnectors.
Therear-panelbinding-postconnectordesignatedLINE
OUTPUT is in parallel with the OUTPUT connector and
canbeusedasaline-leveloutputfeedsimultaneouslywith
the OUTPUT connector. The terminals are numbered 2
and 3 and are in phase with the corresponding pins of the
input connectors. While the line outputs can be used to
drive various impedance lines, the VU meter is calibrated
for use with a 600 Ωline.
Theline output transformerwill operateproperly with up
to 100 mA dc in the line. This feature permits the use of
standard “dialed-up” telephone lines with dc across them.
(Sincea slightdistortionincreasemayoccurathighoutput
levels with maximum dc current, operation with the VU
RANGE switch at +4 dBm is recommended.)
Input Gain Controls
Thefront-panel controls designated1 through4 are thein-
dividual active gain controls for correspondingly numbered
inputs. Notethattheinputconnectorsarelocatedonthe rear
panel directly behind their corresponding gain control. The
controls set the preamplifier gain and provide preamplifier
output attenuation. As the gain is reduced, the preamplifier
input clipping level is increased for that channel.
Input control 1 serves an additional function as the level
control for the tone oscillator when the INPUT 1/OCS 1
switch is in the OSC 1 position.
IMPORTANT: For optimum signal-to-noise ratio, the indi-
vidual input controls should be operated at as high a set-
ting as possible, consistent with maintaining adequate
control range and input clipping level.
Master Gain Control
Thefront-panelcontroldesignatedMASTERisthemas-
ter gain control which sets the overall output level of the
mixed sources (including signals applied to the MIX BUS
input).
Limiter
Thefront-panel LIMITER IN/OUTswitch turnson a fast-
acting, peak-responding limiter circuit that cuts overload
distortion during loud program intervals without affecting
normal program levels. When the LIMITER switch is IN
(operating), the mixer output is limited to approximately
+15dBm. Increasing the individual or MASTER gain con-
trols will increase the average output and the amount of
limiting. Thelimiterthresholdcanberesettoanyotherout-
put between –4 and +18 dBm if desired. With the limiter
switched OUT and tone oscillator activated, adjust INPUT
1 and MASTER level controls to produce an output 0.5 dB
higher than desired. Switch the limiter IN and set the LIM-
ITER THRESHOLD ADJUST control (accessible though
the bottom of the chassis) for the desired level.
The front-panel PEAK LED indicator shows limiter op-
erationwith thelimiter in, and operates when program lev-
elsapproach overloadwith the limiter out. The indicator is
muchfasterthanameterandwillbeactivatedbytheshort-
esttransientpeak,butitremainsonlongenoughtoprovide
easy recognition.
Low-Cut Filters
The low-cut filters provide a low-frequency rolloff to the
response curve as shown in Figure 2. The filters are acti-
vatedbytheLO-CUTIN/OUTswitchaboveeachindividual
input gain control and can be used individually with each
controlto reduce wind noise or undesirable low-frequency
signals such as from condenser microphones or turntable
rumble.
500 1,00050 100 200
20
0
–10
–20
LOW-CUT FILTER ACTION
FIGURE 2

4
Mix Bus
Direct access to the mixing bus is provided through the
rear-panelMIXBUSphonopinjack.Thisprovisionismade
primarily to facilitate stacking or “multing” M267s to
achieveadditionalinputcapacitywithoutlosinganyinputs.
WithtwoM267s,forexample,the two mixing buses aredi-
rectly connected, providing two independent master gain
controlsandtwoisolatedlineamplifierswitheightindividu-
ally controlled inputs. Since the buses are directly paral-
leled,a6dBdropingainwilloccur;andthemasterorinput
controls must be increased to compensate. Noise specifi-
cations are not adversely affected by this interconnection.
Mix bus interconnection can also be made with other
Shure mixers, such as the M268, FP42. etc.
VU Meter
The VU meter is factory-calibrated for use with a 600 Ω
terminated line. The VU RANGE switch on the rear panel
selects either a +4 or +8 dBm output at 0 VU meter indica-
tion. (This switch changes the meter indication but does
not change the actual output level.) Microphone output
levelsare50 dBbelowlineoutput. The+4rangeisrecom-
mended for normal use to provide approximately 14 dB of
headroom from operating level to clipping level.
TheVUmeterisilluminatedbytwoNo.86lampsoperat-
ing well under their normal ratings for a life expectancy of
greater than 10,000 hours. The lamps are only lit during
ac operation. Consequently, the illumination serves as a
visual alarm if the ac is interrupted and the unit has
switched to battery.
The VU meter is connected on the primary side of the
output transformer to assure protection from any dc level
on a telephone line.
Headphones
The headphone outlet appears at the front-panel jack
panel designated PHONES. The two-circuit phone jack
willaccommodatemoststereoor mono headphones. The
output level is sufficient to provide high volume for use in
noisy environments.
Note that the headphone output level is also high
enoughtouseasanauxiliaryunbalancedlinefeedtodrive
a tape deck or a power amplifier.
Thetipandringconnectionsoftheheadphoneplugsare
in phase with pin 3 of all input and output connectors, and
with the tip of the MIX BUS jack.
Tone Oscillator
Thehighly stable,low-distortion tone oscillator provides
forlinetestand level checks. The oscillatorisinstantlyac-
tivated by the front-panel INPUT 1/OSC 1 switch; its level
can then be controlled by the INPUT 1 gain control on the
frontpanel. Thetoneoscillatorfrequencyis1,000Hz,and
the signal appears on both the line and microphone out-
puts, as well as the headphone and mix bus connectors.
The oscillator should be switched off (INPUT 1 position)
when not in use.
Phantom Power
The rear-panel PHANTOM OFF/ON switch controls the
applicationofphantompowerforcondensermicrophones,
such as the Shure SM81 and SM87A, to all inputs. With
theswitch on and the rear-panelMIC/LINE switchesin the
MIC positions, +30 Vdc is applied to pins 2 and 3 of each
input connection. Series current-limiting resistance is 3.3
kΩfor each input. When using other condenser micro-
phones with the M267, verify that the voltage and resis-
tance requirements are compatible.
Note that the phantom power cannot normally be ap-
plied to the inputs with the MIC/LINE switches in the LINE
position.
IMPORTANT: Do
not
turn the PHANTOM switch on when
using
unbalanced
low-impedance microphones; objec-
tionable hum will result. Turn off the PHANTOM switch
when condenser microphones are not being used.
Useonlyhigh-quality cable. Intermittent shortsbetween
brokenshieldwiresandbalancedconductorswillcauseof-
fensive noise transients in the system.
BATTERY OPERATION AND EXTERNAL POWERING
In addition to ac operation, the M267 can be operated
from an internal battery pack. Current drain is typically 17
mAat+8dBmoutput level and typically15mAat+ 4 dBm.
Battery power is recommended both for remote, on-loca-
tion operation, and as an emergency backup source in
case of failure of the ac power.
Access to the battery compartment is provided at the
bottomofthechassis. Three9-voltalkalinebatteriespow-
er the M267 at full rated output. Use alkaline batteries for
maximum life. Duracell MN1604A or Eveready 522 are
recommended. Batterylifeisapproximately20hoursat+4
dBmcontinuosuse. Notethatbatteryoperationwithphan-
tompower loads andhigh levelheadphone monitoring will
increase battery drain.
Withbatteries in the battery compartment,the M267will
automatically and silently switch to battery operation
should the ac voltage fall below a suitable level. If the ac
powerfailscompletely,theVUmeterlampswillgoout,pro-
viding a visual indication of line failure.
Battery condition can be determined by using the BATT
CHECK switch on the front panel. Activate the BATT
CHECK switch and observe the VU meter. A new set of
batterieswill give about a +2VU indication. Batterycondi-
tion is good if the reading is above 0 VU; a lower reading
means that new batteries are required for proper opera-
tion. Note that the M267 power switch must be turned on
to check battery condition.
Telephone Interconnection
Whenusing the M267connected directlyto a telephone
line,checktoseewhetherthelocaltelephonecompanyre-
quiresaninterfacecouplerbetweentheM267andthetele-
phone line. If a coupler is required, make certain the cou-
pler selected and the wiring arrangement are in
compliance with the telephone company regulations.

5
Telephone Line Surge Protection
Whenusing the M267connected directlyto a telephone
linesubjecttolightning-inducedvoltagesurges,thefollow-
ingcommerciallyavailable part canbeinstalledacrossthe
LINE OUT terminals to provide additional protection for
output circuit components:
Metal Oxide Varistor, General Electric Co., Type No.
V22ZA1
ACCESSORIES
A268RRackPanelKit. TheModelA268RRackPanelKit
includes a 19 in. x 3-1/2in. (483 mm x 89 mm) precut rack
panel and necessary hardware for rack-mounting the
M267 (with its cover in place and end caps removed) in a
standard 19 in. (483 mm) rack panel.
RKC169 Rack Panel Bracket Kit. The Model RKC169
RackPanelBracketKitenablesownersoftheShureA68R
Rack Panel Kit (originally designed for the M67 and M68
Mixers) to rack-mount the M267 with the A68R.
SERVICE
WARNING
Voltages in this equpment are harzardous!
Refer servicing to qualified service personnel.
240 Vac Operation
To change the M267 operating voltage from 120 Vac to
240 Vac, follow these steps:
1. Disconnect the M267 from the ac line.
2. Remove the end caps and cover.
3. Locate the voltage selector switch (S201) at the right
rear of the main printed circuit board (Figure 3). Move
SD201 to the 240V position (toward the front panel).
T206
WHT
BLK
120V
240V
F201
F202
T50/250V
240 V WIRING
FIGURE 3
S201
4. Remove fuse F201(0.1A,250V,timelag)andreplace
it with the supplied fuse F202 (0.05A, 250V, time lag).
Note that the F202 fuse holder is at right angles to the
F201 fuse holder.
5. Replace the ac line cord (if necessary) with one de-
signed for the 240 Vac source. If the M267 is to be
used outside the U.S. and Canada, local regulations
may require replacing the line cord with one having
wire insulation colors as follows:
“Live” or
“Hot” Neutral Earth or
Ground
U.S., Canada Black White Green
Europe Brown Blue Green/
Yellow
6. Replace the cover and end caps, and mark the rear
panel to reflect the new operating voltage.

6
PRINTED CIRUCIT BOARDS
COMPONENT SIDE
INPUT TRANSFORMERS T201-T204


9
REPLACEMENT PARTS LIST
REFERENCE
DESIGNATION PART
NUMBER DESCRIPTION COMMERCIAL
ALTERNATE
C101,C209,
C219,C227,
C232
86T628 Capacitor, Electrolytic, 5 µF, 25V SpragueTVA 1303
C115 86L628 Capacitor, Electrolytic, 250 µF, 50V Sprague
501D227F063PR
C201,C204-
C205,C208 86V628 Capacitor, Electrolytic, 22 µF, 6.3V Sprague
501D226F016LL
C210 86M630 Capacitor, Electrolytic, 10 µF, 25V SpragueTE1204
C212-C213 86R630 Capacitor, Electrolytic, 68 µF, 25V Sprague
501D686F025MN
C215,C218 86L626 Capacitor, Electrolytic, 470 µF, 35V Sprague
503D477F035QE
C216,C222 86A630 Capacitor, Electrolytic, 5 µF, 35V SpragueTE1303
C221,C229 86N630 Capacitor, Electrolytic, 22 µF, 35V MalloryF226KM
C223 86S628 Capacitor, Electrolytic, 1 µF, 50V SpragueTVA1300
D209,
D211-D214,
D222-D223,
D226-D229
86A415 Diode,Silicon,Computer, 75V TI1N4148
D210,D217,
D230-D235 86A404 SiliconRectifier, 100V, 1/2A Motorola1N4002
D218-D221 86A405 Diode,Germanium,30V RCA 1N48, 1N60
D301 86F422 Diode,Light-Emitting GeneralInstrument
MV5075C
F201 80F159 Fuse,Slow–Blow, 3AG, 0.1A, 250V Littlefuse313000Se-
ries
F202 80C380 Fuse, TimeLag, 0.05A, 250V Schurter034.3104
J1 95C450 Jack,Phono Switchcraft3511A
J2A, B 90T2600 Connectors,BindingPost None
J101-J104 95B8011 Connector, 3-Pin Female XLR SwitchcraftY3FDPC
J105 95B8012 Connector, 3-Pin Male XLR SwitchcraftY3MPC
J301 90BJ2600 Phone Jack SwitchcraftL-1128PC
L101-L113 80A365 FerriteBeadRing Panasonic
Exc-ELSA35
M1 RKC170
(95A8214) Meter, 190 µA None
MP1-MP5 90A8028 Knob,MIC 1-4, MASTER None
MP6 90A8029 Knobs,PHONE None
MP7 90A8027 Cover, Battery None
MP8-MP9 65A8008 EndCap None
REFERENCE
DESIGNATION PART
NUMBER DESCRIPTION COMMERCIAL
ALTERNATE
PL301-PL302 95A8010 Lamp,6.3V, 0.2A Sylvania86
Q201 86A350 Transistor, NPN Motorola2N5210
Q202,Q204 86A334 Transistor, NPN RohmTIS92
Q203,Q205 86A348 Transistor, PNP Motorola2N5087
Q206 86A335 Transistor, PNP RohmTIS93
Q207 86A8302 Transistor, PNP MotorolaTIP30A
R250 46A8016 Potentiometer, 100k None
R302,R306,
R310,R314 46B8000 Potentiometer, 100k None
R317 46C8000 Potentiometer, 200k None
R322 46D8000 Potentiometer, 5k None
S101-S104 55B8008 Switch, Slide,3PDT None
S105,S302,S306 55B8007 Switch,Slide, DPDT None
S106-S107,S301,
S303-S305 55B8001 Switch,Slide, DPDT None
S201 55A8035 Switch,Slide, DPDT Switchcraft EPS1-PC1
S307 90CB2600 Switch,Pushbutton,SPDT Switchcraft953
S308 55A8009 Switch,Slide,3PDT None
T201-T204 95B8165 Transformer, Input None
T205 51E235A Transformer, Output None
T206 51A8021 Transformer, Power None
U201 86B808A IntegratedCircuit, Quad OpAmpl
(Selectedfor NF) RaytheonRC4156N
U202 86A8908 Opto-Isolator None
U203 86A811A Integrated Circuit, Dual Op Ampl RaytheonRC4559NB
U204 86A806A Integrated Circuit, Quad Comparator RaytheonLM339DB
U205 86A811A Integrated Circuit,Dual OpAmpl RaytheonRC4559NB
U206 86A803 IntegratedCircuit, Dual OpAmpl Motorola MC1458C-P1
U207 86B8930 Integrated Circuit, Voltage Regulator NationalSemiconductor
LM317AT
W1 90A8045 Line Cord, AC None
Parts listed as RKC Kits should be ordered by that kit number.
Other manuals for M267
2
Table of contents
Other Shure Amplifier manuals

Shure
Shure UA830 User manual

Shure
Shure SHA900 User manual

Shure
Shure Solo-Phone SA-1F User manual

Shure
Shure UA834 User manual

Shure
Shure HTS50SPA User manual

Shure
Shure PM300 SERIES Service manual

Shure
Shure SHA900 User manual

Shure
Shure SE20 User manual

Shure
Shure UA845 User manual

Shure
Shure FP11 User manual