Sierra Monitor Corporation 1991 Tarob Court Milpitas, CA 95035 USA (408) 262-6611 (800) 727-4377 Fax: (408) 262-9042
The Model 4400 In-Stream Hydrogen Sulfide Analyzer
isusedtocontinuouslyverifytheH2Scontentofanatu-
ral gas sample for the presence of 0-100 ppm levels of
Hydrogen Sulfide. This system is used to insure that
H2S levels in natural gas collection lines remains at ac-
ceptable levels to help guard against the corrosive ef-
fects of H2S on compressors, pipelines and process
equipment. Itisintendedforcontinuous monitoringprior
to the addition of odorants to the gas.
TheSierraMonitor Model 4400 provides the userwitha
low-cost,easy-to-usesolutionto effective monitoring of
naturalgasstreams. This system accurately measures
H2S concentration in the 0-100 ppm range. Fast re-
sponse of 90% of step change within 30 seconds en-
ables the user to respond quickly to changes in natural
gassupply conditionstopreventproduct contamination.
Thereisminimal maintenance withtheModel4400with
no tapes to replace, no conditioning solutions, no me-
chanicalstreamblenderstocalibrate. Calibrationiseasy
with external application of span gas and simple one
person adjustments. Calibration and swapping of the
gas sensor is a quick and simple operation performed
everytwoweeks.
The 4400-10 receives a low pressure natural gas slip-
streamsample. Aflowcontrollerinthesystemdelivers
a constant flow to the gas sensor and allows for easy
calibrationand maintenance. An in-linecoalescingfilter
protects the system from sample contaminants.
Model 4400
In-Stream Hydrogen Sulfide Analyzer
A4-20mAlinearsignalproportionaltosampleconcen-
tration is provided from the sensor assembly. This sig-
nal can interface with a Sierra Monitor Model 4107-99
Transmitter/Display,a singlechannelcontroller,the Sen-
try multi-channel controller or most industry standard
controllersorPLCs.
TheModel5100-99-IT-ALTransmitter/Displayoptioncan
acceptthe4-20mAsignalfromtheModel4400-10and
provide digital display of the H2S concentration, dual
concentration alarm contacts, 4-20 mA output and se-
rial MODBUS communication. The Model 5100-99-IT-
ALcanbe mounted directlytotheModel4400 H2S Ana-
lyzerorataremote location. The Model 5100-99-IT-AL
ismountedinanexplosion proof enclosure available in
aluminum or stainless steel enclosures.
Features Benefits
No tapes to replace or conditioning solutions Minimal maintenance, no hazardous material to
dispose
Fast response Prevention of product contamination
Simple one-personadjustments Easy calibration, minimal service time