Silent Alert UM3A-2212-EU-PIR User manual

Alert
Movement Activation
Use the following guide to set up your monitor to illuminate the person to person symbol on your Pager or SignWave
when triggered. For advanced settings please refer to instructions overleaf.
2. The test button will flash amber /
green on start up, then flash
amber for up to 30 seconds whilst
the movement sensor stabilises.
This is normal.
Sound Activation
It is possible to enable sound monitoring as well as movement detection. Audio trigger delays can be used to reduce false
alarms from transient noise (door slams etc).
Move Key 12 to the right. Connect the power
supply (PS3A-2207-UK) into the unit, looping
the cable around the strain relief. Plug the
power supply into a mains socket.
If mains failure monitoring is required connect
a 9V Alkaline PP3 to the battery clip.
1.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
UM3A-2212-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENTALERT.IE Silent Alert International, Ireland
TEL +353 (0)1 247 9007
Alkaline
PP3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
Move keys 5 & 7
to the right.
1.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
UM3A-2212-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENTALERT.IE Silent Alert International, Ireland
TEL +353 (0)1 247 9007
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11= Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
Configuration switches
Audio spindle
Test button
PP3 battery clip
Power Supply socket
Passive
infra red
movement
sensor
Turn the spindle on the side of the
monitor half a turn clockwise until the
slot is horizontal.
A good way to test the unit is to
whistle about 2 metres away from it.
More sensitive Less sensitive
2. The test button will light amber
when a sound is detected and
change to green once it has
been accepted.
Switches 7 & 8 alter the
delay period.
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
short medium long
3.
40 - 70cm
3. Position the unit & adjust the
sensor to cover the area you
wish to monitor. Ensure the unit
is at least 40cm from the floor &
fix to the wall with the screws and
wall plugs provided. Use the
keyhole slots in the back of the
unit to secure.
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 Mins
11= Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
38mm
TOP
Drill Template
TM
Silent
Alert
Quick start guide UM3A-2212-EU-PIR
Passive Infra Red (PIR) Movement Monitor
Any questions? Call us on +353 (0)1 247 9007
Silent Alert International www.silentalert.ie +353 (0)1 247 9007

9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
Move Key 9 across to
the right to enable the
movement delay.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2 = System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
Movement return delays
It is possible to add a movement trigger delay to enable a period of time to pass from the sensor
detecting movement to the monitor sending a signal. This can be useful to allow a user get a drink
or visit the bathroom without triggering the system.
A count down timer will start. If the
person returns within the time period the
monitor will disarm and reset.
Now, instead of triggering instantly the
monitor will display it has detected
movement by flashing the test
button orange.
VI
IX III
5 MINUTES
Key 9
=
5 minutes
Keys 9 & 10
=
15 Minutes
Key 10
=
10 minutes
If the monitor doesn't detect
movement in the allotted time it
will send a signal to the
Pager or SignWave.
The timer is configurable as shown.
1. 2. 3.
Changing the system channel code
NOTE: In most cases it is not necessary to change the system code. However, when one or
more systems are in close proximity, system codes can be used to avoid interference from
other SA3000 systems using up to a maximum of 16 channels.
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
The monitor is supplied with no
system code switches set (system code 1).
For reference this is the factory setting
should you need to re-set the unit.
System codes can be set using
key switches 1 - 4.
The diagram to the right shows the 16
possible combinations.
Be sure that the same system code is set on
the receiver to be used and any other
monitoring options in that system.
23456 7 8
9 10 11 12 13 14 15 16
1
The monitor can be coded to light any one of the event symbols on the Pager or SignWave.
The diagram below shows the relevant key settings.
Event Setting
9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
9
10
11
12
13
14
15
16
TM
Silent
Alert
Advanced settings UM3A-2212-EU-PIR
Passive Infra Red (PIR) Movement Monitor
Any questions? Call us on +353 (0)1 247 9007
Silent Alert International www.silentalert.ie +353 (0)1 247 9007

CCM3A-2216-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENTALERT.IE Silent Alert International, Ireland
TEL +353 (0)1 247 9007
MOVE KEY DOWN
TO SWITCH ON
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10= PIR Delay 10 Mins
9& 10 = PIR Delay 15 mins
11= Zone 6
12= Zone 5
13= Zone 4
14= Zone 3
15= Zone 2
16= Zone 1
MOVE KEY DOWN
TO SWITCH ON
CCM 3A-2216-EU-P IR-M KX
MO V EMENT MO N ITOR 11/12/13
U SE MAI NS P O W ER SU P PLY
PS3A-2207-U K O N LY
SILEN T ALERT SA3000 SYSTEM
W W W .SIL ENTALERT. I E Si l en t Alert I nt ernational, Ireland
TEL +353 (0) 1 247 9007
MO VE KEY D OW N
TO S
W
ITCH ON
Transmit the unit
by either:
1. Triggering the PIR
2.Triggering the
sound detection
3. Pressing the
test button
The test button will
briefly light green and a
signal will be sent to the
Pager or SignWave.
Disarm Alerts
It is now possible to disarm the PIR sensor and audio monitoring feature when not required.
1.
3. WARNING
2.
Within 10 seconds after the
unit has transmitted press
and hold the test button
until it lights solid orange.
This shows the unit is now
disabled. It will no longer
respond to any movement
or sound until it
is rearmed.
Disarm the sensors
Rearm the sensors
1. Press and hold the test button.
It will light green briefly and the PIR
will reset.
2. The test button will flash
amber for up to 30 seconds
whilst the movement sensor
stabilises. This is normal.
3.
When the key light goes out
the monitor is armed and
ready to go.
TM
Silent
Alert
Advanced settings UM3A-2212-EU-PIR
Passive Infra Red (PIR) Movement Monitor
Any questions? Call us on +353 (0)1 247 9007
Silent Alert International www.silentalert.ie +353 (0)1 247 9007
Whilst the test button is lit solid orange the monitor will NOT alert the user to an event.
It is important to remember to rearm the monitor when required.
Other Silent Alert Security Sensor manuals
Popular Security Sensor manuals by other brands

elobau
elobau 900614 Translation of the original operating instructions

Satel
Satel GREY manual

System Sensor
System Sensor 4451HTA Installation and maintenance instructions

Olimpia electronics
Olimpia electronics BS-660/A manual

SEBSON
SEBSON GS810 operating instructions

SkyLink
SkyLink WD-101 operating instructions