Photoelectric Beam Detector
PB30-S/PB60-S
Installation Instructions
Please note: This sensor is designed to detect intrusion and to initiate an alarm, it is
not a burglar-preventing device. Maker is not responsible for damage, injury or losses
caused by accident, theft, natural disasters, abuse, misuse, abnormal usage, faulty
installation or improper maintenance.
1. Description
Response time
adjustment
Terminals
Good LED Tamper
Wiring Hole
Power LED
2. Cautions on Installation
Alarm LED
Lens
Monitor jack
Vertical
Adjustment screw
View finder
Cover Transmitter
Receiver Plate
Avoid strong light from sun, auto-
mobile head-lights etc. shining on
transmitter or receiver
Do not install the unit on unsteady
surfaces. Do not install in a site where beam
may be interrupted by trees or
plants, consider seasonal changes.
Do not install in places where units
may be splashed continuously by
dirty water or direct sea spray.
3. Installation Hints
①Remove cover from unit
and slide the mounting
plate to detach it.
②Break grommet on mounting plate
and pull wire through it. Secure
the plate with 4mm screws.
③When exposed wired, break knock-
outs on the rear of unit, pull wire
through as the figure and attach it to
the mounting plate.
④After wiring is completed,
adjust alignment, check
operation and attach cover.
3-1. Wall mount
3-2. Pole mount (Pole size : Φ38 ~ Φ44mm)
①Remove cover from unit and slide the mounting
plate to detach it.
②Attach pole brackets to pole and secure to mounting
plate with screws
4. Response time
Response time
plate
with
screws
.
③Attach sensor body.
④Pull through wire.
⑤Connect terminals.
⑥After wiring is completed, adjust alignment, check
operation and attach cover.
1. Run at full speed
(6.9m/s) - 50msec. 2. Walk with quick steps
(1.2m/s) - 200msec. 3. Walking (0.7m/s)
- 300msec. 4. Walk with slow steps
(0.5m/s) - 500msec. 5~6. Go over a fence(0.3m/s)
- 700msec.
Response
time
adjustment
700ms50ms
5: COM
4: N.O
3: N.C
5. Terminal Arrangement
①②③④⑤⑥
TransmitterReceiver
NO
4
5
Usage
VCC
GND
NO
1
2
Usage
Normal Open
Common
①②
6: Tamper
6. Adjustment and Monitoring
- Monitoring
5
6
GND
Normal Close
2
3
Common
Tamper
Look through view finder on either side
and line-up optics horizontally and vertically
until the opposite unit is visible.
7 Trouble Shooting
Very GoodON3.7 ~ 4V
Alignment GoodON3.0 ~ 3.7V
Alignment againOFFLess than 3.0V
ConditionR:Green LEDMonitoring
Vertical
Adjustment :±10˚
Horizontal
Adjustment :±90˚
Digital
Multi meter
Problem
Power LED dose not light.
Alarm LED does not light when two
beams are broken simultaneously.
No contact under the set condition
Good LED does not operate
7
.
Trouble
Shooting
Possible cause
No power supply.
Bad wiring connection or short.
No power supply.
Bad wiring connection or short.
Resistor short.
Malfunction
Possible Solution
Input DC 10.8 ~15V.
Check wiring connection and repair
if necessary.
Replace.
Replace.
Tx
Rx
8. Specifications & Dimension
Model SASO-PB30S SASO-PB60S
Detection system Simultaneous breaking of 2 beams
Infrared beam Double modulation pulsed beams by LED
Protection range Outdoor 30m
Indoor 60m Outdoor 60m
Indoor 120m
Max. beam range Outdoor 300m
Indoor 300m Outdoor 600m
Indoor 600m
Supply voltage
75
10.8V ~ 15V DC (Non-polarity)
Current 57mA
Response time 50msec to 700msec
LED Transmitter Green LED ON : Power ON
Receiver Green LED(Sensitivity Good) / Red ON : When an alarm is initiated
Alarm output Dry contact relay output form C
Contact action : Interruption time + delay time(1~3 sec)
Contact capacity : 30V(AC/DC) 1A or less
Tamper output Dry contact relay output form N/C(Receiver only)
Contact action : Activated when cover is detached
Contact capacity : 30V(AC/DC) 1A or less
Tempperature -20℃ ~ 60℃
163
Beam adjustment Horizontal : 180˚ (±90˚), Vertical : 20˚ (±10˚)
Mounting position Outdoor / Indoor
Material PC resin(Green)
IP rating IP 44
External dimensions 63 x 163 x 75mm(WxHxD)
Weight Rx : 330g, Tx : 315g
Function Monitor jack output, Frost proof cover
Option Pole attachment(2pcs./set) / Transmitter tamper switch / IP 54
*
Caution : Please consult the instruction manual to ensure safe and proper operation of the product
63
Caution
:
Please
consult
the
instruction
manual
to
ensure
safe
and
proper
operation
of
the
product
.
Specification and design are subject to change without prior notice for improvement.

This manual suits for next models

1

Other Saso Security Sensor manuals

Saso PA-4010PQ User manual

Saso

Saso PA-4010PQ User manual

Saso SASO-PB200L User manual

Saso

Saso SASO-PB200L User manual

Saso SASO-PB D User manual

Saso

Saso SASO-PB D User manual

Saso PA-4610P User manual

Saso

Saso PA-4610P User manual

Saso PA-0112 User manual

Saso

Saso PA-0112 User manual

Saso SASO PB100A User manual

Saso

Saso SASO PB100A User manual

Saso PA-4109W User manual

Saso

Saso PA-4109W User manual

Saso SASO-SH10 User manual

Saso

Saso SASO-SH10 User manual

Saso PA-4510P User manual

Saso

Saso PA-4510P User manual

Saso SASO-PB10S User manual

Saso

Saso SASO-PB10S User manual

Saso CS-10N User manual

Saso

Saso CS-10N User manual

Popular Security Sensor manuals by other brands

BURG-WACHTER BURGsmart Protect WATER 2062 Assembly and user manuals

BURG-WACHTER

BURG-WACHTER BURGsmart Protect WATER 2062 Assembly and user manuals

Theben compact office EIB installation manual

Theben

Theben compact office EIB installation manual

Risco ViTRON RWT6G installation instructions

Risco

Risco ViTRON RWT6G installation instructions

Surface Concept HVPS manual

Surface Concept

Surface Concept HVPS manual

Dors 200 user manual

Dors

Dors 200 user manual

ELRO AG40PR11 manual

ELRO

ELRO AG40PR11 manual

Chamberlain 771E-02 quick start guide

Chamberlain

Chamberlain 771E-02 quick start guide

Emerson Mobrey Instruction leaflet

Emerson

Emerson Mobrey Instruction leaflet

Varian 380-LC Service manual

Varian

Varian 380-LC Service manual

Basalte AURO 0180-02 installation manual

Basalte

Basalte AURO 0180-02 installation manual

Wetekom 92 23 77 instruction manual

Wetekom

Wetekom 92 23 77 instruction manual

ABB Busch-Watchdog 6747-500 AGM Series operating instructions

ABB

ABB Busch-Watchdog 6747-500 AGM Series operating instructions

Eagle L112F manual

Eagle

Eagle L112F manual

Honeywell NFPA 1971 User's information guide

Honeywell

Honeywell NFPA 1971 User's information guide

Recco R9 quick guide

Recco

Recco R9 quick guide

SICK deTec4 Core operating instructions

SICK

SICK deTec4 Core operating instructions

SKYLOTEC LORY Series Instructions for use

SKYLOTEC

SKYLOTEC LORY Series Instructions for use

FDD CR 135-2C installation instructions

FDD

FDD CR 135-2C installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.