DSC iOtega User manual

Wireless Security and Automation
System
User Manual
WARNING:Thismanualcontainsinformationonlimitationsregardingproductuseandfunctionand
informationonthelimitationsastoliabilityofthemanufacturer.Readtheentiremanualcarefully.

Table of Contents
Table of Contents
1.0Aboutyoursecuritysystem 3
1.1Firedetection 3
1.2Carbonmonoxidedetection 3
1.3Testingyoursystem 3
1.4Monitoring 4
1.5Cleaningandmaintenance 4
2.0Generalsystemoperation 5
2.1Integratedkeypad 5
2.2Panelindicators 5
2.3Integratedkeypadquickreference 8
2.4WirelessLCDkeypad 8
2.4.1Wirelesskeypadsymbols 9
2.4.2Wirelesskeypadquickreference 9
2.5Importantnotice 10
2.5.1Powersavemode 10
2.6Languageselection 10
2.7Systemmodels 10
3.0Armingthesystem 11
3.1Stayarming 11
3.1.1Stayarmingontheintegratedkeypad 11
3.1.2Stayarmingonthewirelesskeypad 11
3.2Silentexitdelay 12
3.3No-entryarming 12
3.4Awayarming 12
3.4.1Awayarmingontheintegratedkeypad 12
3.4.2Awayarmingonthewirelesskeypad 12
3.5Quickexit 13
3.5.1Quickexitonthewirelesskeypad 13
3.6Armingerrorsandexitfaults 13
3.6.1Armingerror 13
3.6.2Audibleexitfault 13
3.7Alarmcancelwindow 14
3.8Bypasszones 14
4.0Disarmingthesystem 15
4.1Disarmingontheintegratedkeypad 15
4.2Disarmingonthewirelesskeypad 15
4.3Disarmingerror 15
5.0Usingwirelesskeys 16
6.0Useraccesscodes 17
6.1Accesscodetypes 17
6.1.1Level1access(supervisor/administrator) 17
6.1.2Level2access(basic/standarduser) 18
7.0Additionalfeatures 19
7.1Systemlockoutduetoinvalidattempts 19
7.2Burglaryverification 19
7.3Swingershutdown 19
7.4Firealarmverification 19
8.0Emergencykeys 20
8.1Emergencykeysontheintegratedkeypad 20
8.2Emergencykeysonthewirelesskeypad 20
8.3Whenalarmsounds 20
8.3.1Firealarmpulsedsiren(temporal3) 21
8.3.2Carbonmonoxide(CO)alarm 21
8.3.3Intrusion(burglary)alarm 21
- 2 -

Table of Contents
9.0Viewingtroubles 22
10.0UsingZ-WaveDevices 24
10.1Z-WaveAllianceCertification 24
10.2AddingorRemovingaController 24
10.3ReplicatingaController 24
10.4ControllerLearnMode 24
10.5ChangingthePrimaryController 24
10.6AddingaDevice 24
10.6.1EditingorRemovingaDevice 25
10.7DeviceInteroperability 25
10.8Z-WaveAssociationGroups 25
10.9RespondingtotheBasicCommand 25
10.10Z-WaveReset 25
11.0Safetyinstructions 26
12.0Locatingdetectorsandescapeplan 27
12.1Smokedetectors 27
12.2Fireescapeplanning 28
12.3Carbonmonoxidedetectors 29
12.0Regulatoryagencystatements 30
13.0Referencesheets 32
13.1Systeminformation 32
13.2Servicecontactinformation 32
- 3 -

Chapter 1.0 About your security system
1.0 About your security system
Readthismanualcarefullyandhaveyourinstallerinstructyouonyoursystem'soperationandon
whichfeatureshavebeenimplementedinyoursystem.Allusersofthissystemmustbefullyinstruc-
tedinitsuse.FillouttheSystemInformationpagewithallofyourzoneinformationandaccess
codes,andstorethismanualinasafeplaceforfuturereference.
Note:Theiotegasecuritysystemincludesspecificfalsealarmreductionfeaturesandisclassified
inaccordancewithANSI/SIACP-01-2014ControlPanelStandard-FeaturesforFalseAlarm
Reduction.Consultyourinstallerforfurtherinformationregardingthefalsealarmreductionfea-
turesbuiltintoyoursystem,asthismanualdoesnotcoverallfeatures.
1.1 Fire detection
Ifyourinstallerenablesthisfeature,thissystemcanmonitorfiredetectiondevices,suchassmoke
detectors,andprovideawarningifafireconditionisdetected.Goodfiredetectiondependsonhav-
inganadequatenumberofdetectorsplacedinappropriatelocations.Thisequipmentmustbe
installedinaccordancewithNFPA72(N.F.P.A.,BatterymarchPark,QuinceyMA02269).Care-
fullyreviewtheFireEscapePlanningsectioninthismanual.
1.2 Carbon monoxide detection
Ifyourinstallerenablesthisfeature,thissystemcanmonitorcarbonmonoxidedetectorsand
provideawarningifcarbonmonoxideisdetected.RefertotheFireescapeplanningandCarbon
monoxidedetectorssectionsformoreinformation.
1.3 Testing your system
Thesystemtestactivatesa4-secondcheckofthesystemstatusLEDs,keypadLEDs,buzzer,and
siren.Itisapartition-basedtestandmustbedonewhenthesystemisdisarmed.
Youcanperformasystemtestfromthewebportal.
Thefollowingeventshappenduringasystemtest:
lAllsystemstatusLEDsflashfor4seconds.
lAsystemtesttransmitstothemonitoringstation.
lThesystemchecksthebackupbatterylevel.
lThekeypadLEDsilluminatefor4seconds.
lThesystembuzzersoundsfor4seconds,orthepartitionbuzzerandsirensoundfor2
secondseachinseries.
Testyoursystemweeklytoensurethatitfunctionsasintended.Informyourmonitoringstation
whenyoubeginandendsystemtesting.
Aqualifiedservicetechnicianmusttesthouseholdfirealarmsystemsatleastevery3yearsin
accordancewithNFPA72.Itisyourresponsibilitytotestthesystemweekly,excludingsmoke
detectors.
Ifthesystemfailstofunctionproperly,callyourinstallationcompanyforservice.
- 3 -

Chapter 1.0 About your security system
1.4 Monitoring
Thissystemcantransmitalarms,troublesandemergencyinformation.Ifyouinitiateanalarmby
mistake,immediatelycallthemonitoringstationtopreventanunnecessaryresponse.
Notes:
lYourinstallermustenablethemonitoringfunctionbeforeitisfunctional.
lConsultwithyourinstallertodetermineifyoursystemisconfiguredwithacommunicator
delay.Acommunicatordelaypreventsareporttothemonitoringstationifthecontrol
panelisdisarmedwithin30-45secondsafteranintrusionalarmistriggered.Notethat
fire-typealarmsarenormallyreportedwithoutadelay.
lIfenabledandconfigured,youcancelanalarmafterthecommunicationdelaywiththe
alarmcancelwindow.RefertotheAlarmcancelwindowsectionformoreinformation.
lContactyourinstallertoverifythatyoursystemiscompatiblewiththeCentralStation
Receiverformatatyearlyintervals.
1.5 Cleaning and maintenance
KeepyourAlarmControllerinoptimalconditionbyfollowingalltheinstructionsthatareincluded
withinthismanualand/ormarkedontheproduct.Itistheend-user'sand/orinstaller’sresponsibility
todisposeofusedbatteriesaccordingtothewasterecoveryandrecyclingregulationsapplicableto
thelocalmarket.
lCleantheunitbylightlydustingwithaslightlymoistenedcloth.
lDonotwipethefrontcoverwithalcohol.
lDonotusewateroranyotherliquid.
lDonotuseabrasives,thinners,solventsoraerosolcleaners(spraypolish)thatmayenter
throughholesandcausedamage.
lReplacethestandbybatteryevery3-5years.
Forothersystemdevicesorsensors,consultthemanufacturer’sliteraturefortestingandmain-
tenanceinstructions.
- 4 -

Chapter 2.0 General system operation
2.0 General system operation
Yoursecuritysystemcomprisesanintegratedalarmcontrol/panelandvarioussensorsanddetectors.
Thesystemisself-contained;thecontrolpanel,integratedkeypad,andstandbybatteryareall
housedwithintheunit.
Thesecuritysystemhasseveralzonesofareaprotection.Azoneisasensorordetectorthatcom-
municateswiththepanel.Asensorinalarmisindicatedontheintegratedkeypad,wirelesskeypad,
touchscreenkeypad,andbymessagesonthemobilephoneuserapplication.
2.1 Integrated keypad
Theiotegasystemincludesacapacitivetouchintegratedkeypadwith16keys:numbers0thru9,*,
#,Fire,Auxiliary,Panicemergencykeys,andshift(uparrow).
Duringpowerup,thenumberkeysilluminateinsequenceseveraltimes.Innormaloperation,the
keypadremainsoffwhennotinuse.Whenyouwaveyourhandincloseproximitytothekeypad,the
numberkeysilluminate.
Notes:
lTheemergencykeysdonotilluminateunlessyoutaptheshiftkey.SeetheEmergency
Keyssectionformoreinformation.
lYoucanonlyusethekeypadforarming,disarming,andtheemergencykeys.Thesame
functionsareavailablewhenswitchingbetweenpartitions.
2.2 Panel indicators
TheiotegasystemincludessevenLEDstatusindicators:
lFoursingle-colorLEDs
lThreemulti-colorLEDs(red,green,amber)
- 5 -

Chapter 2.0 General system operation
1234 765
Item Description
1 PowerLED
2 ReadytoArmLED
3 ArmedLED
4 TroubleLED
5 WiFiSignalStrengthLED
6 CellularSignalStrengthLED
7 RemoteConnectionLED
Power
Status LED Indication Description
ON(green) ACpowerisconnectedtothesystem.
Flashing(green) SystemTest
AllstatusLEDsflashatthesametime.
OFF ThereisnoACpowertothesystem.
Ready to Arm
Status LED Indication Description
ON(green) Thepartitionisreadytoarm.Therearenofireor
COalarmconditions.
Flashing(green) SystemTest
AllstatusLEDsflashatthesametime.
InstallerWalkTest
Ready,Trouble,andArmLEDsflashatthesame
time.
OFF Thesystemisnotreadytoarm.
AfireorCOalarmconditionispresent.
- 6 -

Chapter 2.0 General system operation
Armed
Status LED Indication Description
ON(red) Thepartitionisarmed..
Flashing(red) ThepartitionisinAlarm.
Note:SilentalarmsorpanicsdonotflashtheAlarm
LED.
SystemTest
AllstatusLEDsflashatthesametime.
InstallerWalkTest
Ready,Trouble,andArmLEDsflashatthesame
time.
OFF Thepartitionisdisarmed
Trouble
Status LED Indication Description
ON(amber) Asystemtroubleispresent.
Flashing(amber)
[cadenceof500ms
On/500msOFF]
[*][2]TheTroublemenuisaccessed.
Flashing(amber)
[cadenceof250ms
ON/250msOFF/250ms
ON/750msOFF]
Thesystemisinthesecond-levelsubmenu.
Flashing(amber)
[cadenceof250ms
ON/250msOFF/250ms
ON/250msOFF/250ms
ON/750msOFF]
Thesystemisinthethird-levelsubmenu.
Flashing(amber) SystemTest
AllstatusLEDsflashatthesametime.
InstallerWalkTest
Ready,Trouble,andArmLEDsflashatthesame
time.
OFF Systemtroublesarecleared.
WiFi Signal Strength
Status LED Indication Description
ON(green) Theradioisactivewithastrongsignalconnection.
ON(amber) Theradioisactivewithaweaksignalconnection.
ON(red) Thereisnosignal.
Flashing(green). TheradioisactiveinWiFiprotectedsetup(WPS)
modeforaccesspoint(AP)mode.
Flashing(amber) Z-Waveradioisactiveinlearnpairmode
Flashing(amber) SystemTest
AllstatusLEDsflashatthesametime.
OFF Theradioisinactiveornotconnectedtothenetwork.
- 7 -

Chapter 2.0 General system operation
Cellular Signal Strength
Status LED Indication Description
ON(green) Cellularisactivewithastrongsignalconnection.
ON(amber) Cellularisactivewithaweaksignalconnection.
ON(red) Acommunicatorisinstalledbutthereisnosignalor
connection
Flashing(amber) SystemTest
AllstatusLEDsflashatthesametime.
OFF Acommunicatorisnotinstalledornotconfigured.
Remote Connection Status
Status LED Indication Description
ON(green) Thelinkisactivewithaserver.
Flashing(red) Thelinkactivatesbutfailstocommunicatewiththe
server.
Flashing(amber) SystemTest
AllstatusLEDsflashatthesametime.
OFF Thelinkisnotyetactivewithanyserver.
Note:IftheRemoteConnectionstatusLEDflashesred,theservermaybeundergoingmain-
tenanceorexperiencingtechnicaldifficulties.Restartingthepanelmayremedytheissue.Ifthe
problempersists,contactyourinstaller.
2.3 Integrated keypad quick reference
Usethefollowingtableforquickreferenceoftheintegratedkeypadoptions:
Action Enter
Awayarm [AccessCode]
Stayarm [AccessCode]
Disarm [AccessCode]
Abortarmingsequence [AccessCode]
System troubles
Silencetroubles [Anykey]or[*][2]+[Accesscode1]
Viewtroubles [*][2]+[Accesscode1]+[Troublecode]
1ForULlistedinstallations,youmustenteryouraccesscodetosilencetroublebeepsandviewsys-
temtroubles.
2.4 Wireless LCD keypad
Theiotegasystemsupportsthefollowingkeypadmodel:
WS9LCDWFx WirelessAlphanumericLCDkeypad
- 8 -

Chapter 2.0 General system operation
2.4.1 Wireless keypad symbols
Status
LED Indication Description
Readyto
arm
ON(green) Thepartitionisreadytoarm.Therearenofireor
COalarmconditions.
Armed ON/flashing(red) Thepartitionisarmed..
Trouble ON(yellow) Asystemtroubleispresent.
Flashing Keypadlowbattery
Power ON(green) ACpowerisconnectedtothekeypad.
2.4.2 Wireless keypad quick reference
Whenusingthewirelesskeypad,theiotegasystemusesshortcutkeystoaccessoptionsorfeatures.
Additionally,itusesamenu-basednavigationsystem.Usethescrollkeystoscrollthroughthelistof
optionscontainedwithinthecurrentmenu.
Note:Yourinstallermustenableandconfiguresomefeatures.
Action Press
AwayArm for2seconds+[AccessCode1]
StayArm for2seconds+[AccessCode1]
Disarm [AccessCode]
Abortarmingsequence [AccessCode]
Bypassing - All bypass commands begin with [*][1] + [Access Code1]
Bypassindividualzones [3-digitzone#]
Common functions
TurnchimeON/OFF for2seconds
Changebrightness [*][6]+[Mastercode]+
Changecontrast [*][6]+[MasterCode]+
Viewtroubles [*][2]+[Accesscode2]+
Viewalarms [*][3]+
Buzzervolume [*][6]+[MasterCode]+
Languageselection [*][6]+[MasterCode]+
1Ifconfiguredbyyourinstaller
2ForULlistedinstallations,youmustenteryouraccesscodetosilencetroublebeepsandviewsys-
temtroubles.
- 9 -

Chapter 2.0 General system operation
2.5 Important notice
Asecuritysystemcannotpreventemergencies.Itisonlyintendedtoalertyouandyourmonitoring
station,ifapplicable,toanemergencysituation.Securitysystemsaregenerallyveryreliable,but
theymaynotworkunderallconditionsandtheyarenotasubstituteforprudentsecuritypracticesor
lifeandpropertyinsurance.Yoursecuritysystemmustbeinstalledandservicedbyqualifiedsecur-
ityprofessionals.Theseprofessionalscaninstructyouonthelevelofprotectionthathasbeen
providedandonsystemoperations.
2.5.1 Power save mode
WhenthepanelisinPowerSavemode,itissavingbatterylife.Theintegratedkeypadisnotturned
onuntilthereisaspecificreason,suchasahandwaveinfrontofthepanel,orthestartofanentry
delay.
Wheninitiated,thestatusindicatorsstayonfor30secondsbeforeturningoff.Inthismode,the
panelisstillfunctioning,butnothingisvisible.
Note:ForULlistedinstallations,theuserappandtouchscreenkeypadfunctionsarenotavailable
inthismode;therefore,youmustusetheintegratedkeypadorthewirelesskeypadtoarmordisarm
thesystem.
2.6 Language selection
Thesystemsupportsthefollowingthreelanguages:
lEnglish
lFrench
lSpanish
Youcanselectthelanguageonthetouchscreenkeypadorthewirelesskeypad.
2.7 System models
ThereferencetoWS900inthismanualcoversthefollowingmodels:
WS900-29* Alarmsystemwithtwo-wayaudiosupport,operatingin912-919MHzband
WS900-19* Alarmsystemwithtwo-wayaudiosupport,operatingin912-919MHzband
3G7090* 3GCellularAlarmCommunicator
LT7090* VerizonLTEOnlyCellularCommunicator
(*)ThesedevicesareUL/ULClisted.
WS900-28 Alarmsystemoperatingin868MHzband
WS901-18 Alarmsystemoperatingin868MHzband
WS901-24EU Alarmsystemoperatingin433MHzband
WS901-14 Alarmsystemoperatingin433MHzband
3G7090-EU 3GCellularAlarmCommunicator
Note:Two-wayaudiosupportwasnotevaluatedbyUL/ULC.
- 10 -

Chapter 3.0 Arming the system
3.0 Arming the system
Youcanarmthesystemusingthefollowingoptions:
lIntegratedkeypad
lWirelesskeypad
lTouchscreenkeypad
lUserapp(OperationwiththeuserappwasnotevaluatedbyUL/ULC.)
lWirelesskey(RefertotheUsingwirelesskeyssectionforalistofUL/ULClistedcom-
patiblewirelesskeys.)
3.1 Stay arming
Stayarmingarmsonlytheperimeterofthepremisespermittingmovementinside.
Note:ToarmthesysteminStaymode,yourinstallermustenrollandconfigureatleastonezoneas
anInteriorStay/AwayoraDelayStay/Awaytypeofzone.
3.1.1 Stay arming on the integrated keypad
ToarmthesysteminStaymodeontheintegratedkeypad,completethefollowingsteps:
1. EnsureallprotecteddoorsandwindowsaresecureorbypassedandthattheReadyindic-
atorison.
2. Enteryouraccesscodeanddonotleavethepremises.Thesystemautomaticallyignores
bypassedzonesandinitiatestheexitdelaycountdown.
Tocancelthearmingsequence,enteryouraccesscode.
Whenexitdelayisactive,theArmedandReadyindicatorsturnonandthekeypadbeepsonceper
second.Whentheexitdelayexpires,thesystemisarmedandisindicatedbytheReadyindicator
turningoffandtheArmedindicatorstayingon.
Note:ForSIACP-01listedpanels,theStayarmingexitdelaywillbetwiceaslongastheAway
armingexitdelay.
IfyoursystemisinstalledinaccordancewithSIACP-01StandardforFalseAlarmReduction,the
securitysystemarmsintheStaymodeiftheexitdelaytimeexpiresandtherewasnoexit.
Ifyouarmthesystemremotelywithoutexitdelay,thesecuritysystemarmsinAwaymodeonly.
3.1.2 Stay arming on the wireless keypad
Staymodepartiallyactivatesyouralarmsystembyarmingallperimetersensorsandbypassingall
interiorsensors.
ToarmthesysteminStaymode,completethefollowingsteps:
1. EnsureallprotecteddoorsandwindowsaresecureorbypassedandthattheReadyindic-
atorison.
2. Enteryouraccesscode.
OR
PressandholdtheStayArmfunctionkeyfor2secondsandenteryouraccesscode,if
required.
Ifzoneshavebeenbypassed,awarningappears
Aftersuccessfullyinitiatingthearmingsequence,thefollowingeventsoccur:
lArmedindicatorturnson.
lReadyindicatorremainson.
- 11 -

Chapter 3.0 Arming the system
lExitDelaytimerbeginscountingdown.
Whentheexitdelaytimerexpires,armingthesystem,thefollowingeventsoccur:
lReadyindicatorturnsoff..
lArmedindicatorremainson.
lBypassorsystemindicatoractivates
Tocancelthearmingsequence,enteryouraccesscode.
3.2 Silent exit delay
IfthesystemisarmedinStaymodeorusingtheNo-entryarmingmethod,thekeypadbuzzeris
silencedandtheexittimeisdoubledforthatexitperiodonly.(SIACP-01only.)
3.3 No-entry arming
No-entryarmingarmsthesysteminStayorAwaymodeaftertheexitdelayexpiresandremoves
theentrydelay.
Notes:
lAllzonesprogrammedasDelayfunctionthesamewayasinstantzones.
lThisfeatureisonlyavailableonthetouchscreenkeypadanduserapp.
3.4 Away arming
Awayarmingarmstheentiresystem,includingtheperimeterandinteriordevices.
3.4.1 Away arming on the integrated keypad
ToarmthesysteminAwaymodeontheintegratedkeypad,completethefollowingsteps:
1. EnsureallprotecteddoorsandwindowsaresecureorbypassedandthattheReadyindic-
atorison.
2. Enteryouraccesscode.Exitdelaybegins.Exitthepremisesthroughadoorprogrammed
asentry/exittype.
Tocancelthearmingsequence,enteryouraccesscode.
Whenexitdelayisactive,theArmedandReadyindicatorsturnonandthekeypadbeepsonceper
second.Dependingonyoursystemconfiguration,youhave____secondstoexitthepremises.Your
installercanprogramthistime.
Thekeypadbuzzeremitsarapidpulsatingrateduringthelast10secondsoftheexitdelaytoindic-
atethatthetimeisexpiring.
Whenexitdelayisactive,theArmedandReadyindicatorsturnonandthekeypadbeepsonceper
second.Whentheexitdelayexpires,thesystemisarmedandisindicatedbytheReadyindicator
turningoffandtheArmedindicatorstayingon.
Note:InAwayarmingmode,manuallybypassedzonesareloggedandcommunicatedtothemon-
itoringstation.
IfyoursystemisinstalledinaccordancewithSIACP-01StandardforFalseAlarmReduction,the
followingconditionapplies:Violationandrestoral,followedbyasecondviolationoftheentry/exit
zonebeforetheendoftheexitdelay,restartstheexitdelay.
3.4.2 Away arming on the wireless keypad
ToarmthesysteminAwaymode,completethefollowingsteps:
1. EnsureallprotecteddoorsandwindowsaresecureorbypassedandthattheReadyindic-
atorison.
- 12 -

Chapter 3.0 Arming the system
2. Enteryouraccesscode.
OR
PressandholdtheAwayArmfunctionkeyfor2secondsandenteryouraccesscode,if
required.
Ifzoneshavebeenbypassed,awarningappears
Tocancelthearmingsequence,enteryouraccesscode.
Note:Yourinstallerconfigurestheexitdelaytime.
3.5 Quick exit
Ifthesystemisarmedandyoumustexit,usetheQuickExitfunctiontoavoiddisarmingandrearm-
ingthesystem.Usingthisfunctiongivesyou2minutestoexitthepremises.Whenthedoorisclosed
afterexiting,theremainingexittimeiscancelled.
Note:Thisfeatureisnotavailableontheintegratedkeypad.
3.5.1 Quick exit on the wireless keypad
TousetheQuickExitfunctiononthewirelesskeypad,completethefollowingsteps:
1. WhensystemisarmedandtheArmedindicatorison,pressandholdtheQuickExitkey
for2seconds..
2. Exitthepremisesbeforetheexitdelaytimerexpires.Afterexiting,thedelaytimeriscan-
celed.
3.6 Arming errors and exit faults
Yoursecuritysystemaudiblynotifiesyouofanyerrorswhenyouareattemptingtoarmthesystem
orexitthepremises.
3.6.1 Arming error
Anerrortone(longbeep)soundsifthesystemisunabletoarm.Armingerrorsoccurunderthefol-
lowingconditions:
lThesystemisnotreadytoarm,i.e.sensorsareopen
lTheaccesscodeisincorrect.
lAtroubleconditionispresent.
Ensureallsensorsaresecureandthesystemisreadytoarm,thentryagain.
3.6.2 Audible exit fault
Toreducefalsealarms,theaudibleexitfaultnotifiesyouofanimproperexitwhenarmingthesys-
tem.Iftheentry/exitdoorisnotsecurelyclosedduringtheprogrammedexitdelay,thesystem
soundsthealarmtoindicateanimproperexit.
Tocorrectanexitfault,completethefollowingsteps:
1. Re-enterthepremises.
2. Enteryouraccesscodetodisarmthesystembeforetheentrydelaytimerexpires
3. Ensureallsensorsaresecureandthesystemisreadytoarm.
4. RepeattheAwayarmingprocedure.
- 13 -

Chapter 3.0 Arming the system
3.7 Alarm cancel window
Thereisaperiodoftimeinwhichyoucancancelthealarmtransmission.Whentheprogrammed
alarmtransmissiondelayexpires,cancelinganalarmsendsamessagetothemonitoringstation.
Whenthecancellationmessageissuccessfullytransmitted,thesystembeepssixtimes.
Note:
lYourinstallermustenableandconfigurethisfeature.
lForCP-01systems,alarmtransmissiondelaymustnotexceed45seconds.
3.8 Bypass zones
Usethezonebypassingfeaturewhenyouneedaccesstoaprotectedareawhilethesystemis
armed,orwhenazoneistemporarilyoutofservice,butyouneedtoarmthesystem.Bypassed
zonesarenotabletosoundanalarm.Asaresult,bypassingzonesreducesthelevelofsecurity.If
youarebypassingazonebecauseitisnotworking,callaservicetechnicianimmediatelytoresolve
theproblemandrestoreyoursystemtoproperworkingorder.
Ensurethatnozonesareunintentionallybypassedwhenarmingyoursystem.Zonescannotbe
bypassedoncethesystemisarmed.Bypassedzones,exceptfor24-hourzones,areautomatically
unbypassedeachtimethesystemisdisarmedandmustbebypassedagainbeforethenextarming,if
needed.
Notes:
l24-hourzonescanonlybeunbypassedmanually.
lForULlistedinstallations,zonescanonlybebypassedmanually.
- 14 -

Chapter 4.0 Disarming the system
4.0 Disarming the system
Youcanarmthesystemusingthefollowingoptions:
lIntegratedkeypad
lTouchscreenkeypad
lWirelesskeypad
lUserapp(OperationwiththeuserappwasnotevaluatedbyUL/ULC.)
lWirelesskey(RefertotheUsingwirelesskeyssectionforalistofUL/ULClistedcom-
patiblewirelesskeys.)
4.1 Disarming on the integrated keypad
Todisarmthesystemontheintegratedkeypad,completethefollowingsteps:
1. Enteryouraccesscode.
2. Ifyouopentheentry/exitdoor,acontinuoustoneindicatesthatentrydelayhasstarted.
Enteryouraccesscodewithin____secondstoavoidanalarmcondition.Yourinstaller
canprogramthistime.
Note:Whendisarmingthesystemduringentrydelay,thetoneissilencedwhenyouenterthefirst
digitofyouraccesscode.Ifyouraccesscodeisinvalid,thetonestartsagain.
4.2 Disarming on the wireless keypad
Todisarmthesystemonthewirelesskeypad,completethefollowingsteps:
1. Enteryouraccesscodewhenthesystemisarmed.(Armedindicatorison).
2. Ifyouwalkthroughtheentrydoor,thekeypadbeeps.Disarmwithin_____secondsto
avoidanalarmcondition.
4.3 Disarming error
Ifyouraccesscodeisinvalid,thesystemdoesnotdisarmandemitsa2-seconderrortone.Ifthis
happens,press[#]andtryagaintoensurethatyouenteredavalidaccesscode.Ifithappensagain,
theaccesscodemaybeinvalid.
- 15 -

Chapter 5.0 Using wireless keys
5.0 Using wireless keys
Inadditiontothekeypad,youcancontrolyoursystemwithtwo-waywirelesskeys.Allwireless
keybuttonsareprogrammable.Yourinstallercanverifythefunctionsforeachkey.
Usingatwo-waywirelesskey,youcanarmordisarmthesystemwhileyouareincloseproximity
toyourhouse,oryoucancallforhelp.
Thefollowingwirelesskeysarecompatiblewiththeiotegasystem:
Note:Thebuttonfunctionslistedarethedefaultforeachwirelesskey.
PG4929/PG8929/PG9929 PG4939/PG8939/PG9939 PG4949/PG8949/PG9949
5
6
1
2
3
4
1
2
4
3
5
21
3
1. AwayArm
2. StayArm
3. Disarm
4. Panic
5. MessageLED
6. StatusLEDs
1. AwayArm
2. StayArm
3. Disarm
4. Panic
5. LED
1. AwayArm
2. Disarm
3. Panic
Note:ThepanicfeatureisdisabledonPGx929andPGx939forSIACP-01certifiedinstallations.
AuseratMasterorAdministratorlevelcanassignenrolledwirelesskeystootherusers.
Toarmthesystemwithawirelesskey,pressthedesiredarmingmodebuttonwhentheReadyindic-
atorison.
Note:Whenarmingthesystemwithatwo-waywirelesskey,thesystemsquawksoncetoindicate
thesystemisarmed.
Todisarmthesystemwithatwo-waywirelesskey,completethefollowingsteps:
1. Pressthedisarmbutton.
2. Ifyouwalkthroughtheentrydoor,thekeypadbeeps.Pressthedisarmbuttonwithin____
secondstoavoidanalarmcondition.
Note:Whendisarmingthesystemwithatwo-waywirelesskey,thesystemsquawkstwicetoindic-
atethesystemisdisarmed.
- 16 -

Chapter 6.0 User access codes
6.0 User access codes
Theiotegasystemsupportsupto100users,includingtheMasteruser.Bydefault,user#1isthe
Masteruser.Youcannotdisableordeletethisuserfromthesystem.Thesystemalsosupportsan
additionaltwoduresscodes,oneforeachpartition.
Fromthetouchscreenkeypad,youcanprogramandconfigureusertypesforusers2through100.
Youcanassignausertooneorbothpartitionsandenableordisablesysteminteraction.
Useraccesscodesarefourdigitsandmustbeunique;thesystemdoesnotduplicatecodes.Ifyou
programaduplicatecode,thesystemerrorsandrejectsthecode.Ifyoutrytochangeanexisting
usercodetoaonethatisalreadyprogrammed,thesystemerrorsandrejectsthechange.
6.1 Access code types
Theiotegasystemprovidesthefollowinguseraccesscodetypes:
Master code Thisisthesystemmastercode.Youcannotdisableordeletethiscode,butyou
canchangeitintheuserapporonthetouchscreenkeypad.Usethiscodetopro-
gramallotheraccesscodes,includingtheduresscodes.Youcanusethiscode
todoalluser-levelfunctions,excepttoaccessInstallermode.
User codes Therearetwoaccesslevelsforusercodes:
lLevel1-Supervisor/Administrator
lLevel2-Basic/StandardUser
Eachlevelhasdifferentpermissions.Seethefollowingsectionsfordescrip-
tionsofeachlevel.
Duress codes Useduresscodestodisarmthesystemonlyinanemergencysituation.When
used,anemergencydisarmeventtransmitstothemonitoringstation.Thesys-
temsupportstwoduresscodes,oneforeachpartition.Thesecodesare
excludedfromthetotalnumberofavailablecodes.Theyhavetheaccesslevel
ofaLevel2BasicUser.
6.1.1 Level 1 access (supervisor/administrator)
Usersatthislevelhavesimilarprivilegestothemasteruserbutarelimitedbasedontheirpartition
assignment.Userscandothefollowingactionsontheirpartitions:
lArm/disarm
lBypass/unbypass
lChimeenable/disable
lViewtroubles
Level1userscanalsodoanyuserlevelfunctionalityonthekeypadoruserapp,asfollows:
lInitiatesystemtest
lEnableinstallerorremoteaccess
lLanguageselection
lVieweventbuffer
lViewPowerGcameraimages
lProgramzoneandpartitionlabels
lScheduleAutoArming
lInitiatefirmwareupdates
lUpdatethesystemWiFiSSIDandpassword
- 17 -

Chapter 6.0 User access codes
lCreatenewusersanduserlabels
lProgramduresscodes
Note:Userscanonlyadd,edit,ordeleteusersthatareassignedtothesamepartitionastheyare.
6.1.2 Level 2 access (basic/standard user)
Usersatthislevelhaveaccesstobasicsecurityfunctionsbutarelimitedbasedontheirpartition
assignment.Userscandothefollowingactionsontheirpartitions:
lArm/disarm
lBypass/unbypass
lChimeenable/disable
lViewsystemtroubles
lViewalarmmemory
lVieweventhistory
- 18 -

Chapter 7.0 Additional features
7.0 Additional features
Thefollowingsectionslistadditionalfeatureofyouriotegasystem.
7.1 System lockout due to invalid attempts
Ifconfigured,yoursystemautomaticallylocksoutinputsfromallkeypadsforaspecifiedduration
ifyouentertoomanyinvalidaccesscodes.Whenyoutaporpressanykeys,anerrortonesounds.
Emergencykeysarestillactiveduringkeypadlockout.
Note:Yourinstallermustconfigurethisfeatureandthelockoutduration.
7.2 Burglary verification
Thecontrolpanelincludescrosszoneandsequentialdetectionfeaturesthatrequireatripontwoor
morezoneswithinagiventimeperiod,togenerateaconfirmedalarmforpoliceresponse.
Note:Yourinstallermustenableandconfigurethisfeature.
7.3 Swinger shutdown
Thepanelhasaswingershutdownfeaturethatshutsdownazoneafteraprogrammablenumberof
trips.AllburglaryzonetypeshavethisfeatureenabledinCP-01installations.
ForSIACP-01classifiedinstallations,theswingershutdownfeatureisprogrammedsuchthatone
ortwotripsshutsdownthezone.Thezoneisrestoredafteramanualresetbyenteringtheaccess
codeatthetimeofdisarmingthealarmsystem,oritisresetautomaticallyafter8hourswithno
tripsonanyzones.
Note:Yourinstallermustbeenableandconfigurethisfeature.
7.4 Fire alarm verification
Firealarmverificationisanavailableoptionforfirezones.Ifconfigured,whentheconditionsfor
alarmverificationaremetthefirealarmsoundsandanalarmtransmissionissenttothemonitoring
station.
Note:Yourinstallermustbeenableandconfigurethisfeature.
- 19 -
Other manuals for iOtega
2
Table of contents
Other DSC Security System manuals

DSC
DSC SYSTEM MASTER PC4000 User manual

DSC
DSC PC1832 series Owner's manual

DSC
DSC ESCORT558O User manual

DSC
DSC IMPASSA User manual

DSC
DSC PC 5010 User manual

DSC
DSC Envoy NT9005 V1.0 Operating instructions

DSC
DSC PC560 User manual

DSC
DSC PC560 User manual

DSC
DSC PDigital Security PC1565 User manual

DSC
DSC PC1575 Operating instructions