manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Skyrc
  6. •
  7. Measuring Instrument
  8. •
  9. Skyrc SK - 500040 User manual

Skyrc SK - 500040 User manual

Congratulations on the purchase of SkyRC Angle Gauge!
The gauge consists of three sensing modules, which are wirelessly controlled through Bluetooth. It
measures the surface angle and relative angle difference.
Download the RC Gears app to get started to measure the real-time measuring data.
Measuring Angles
SKYRC Angle Gauge Instruction Manual
SKYRC Angle Gauge x3
LED Indicator
* Actual angle to measure * The right-angle side is the reference side for
measuring
Switch
ChargePort
GNSS Performance Analyzer
GSM020
Corner Weight System
SCWS2000
Center of Gravity Gauge
CGG-020 & SAM-020
RC Gears Model oneName
Center of Gravity Gauge
4. Set and input the angle in reference to the model aircraft manual.
5. Set the angle to the maximum with the remote control, and check whether the calibration range
meets the requirements indicated in the manual.
ZERO
Reference angle
Up aileron
Name Model one Elevator Reference: sensor - relative Angle Set angle
Down aileron
Up elevator
Down elevator
Up flap
Down flap
Left angle
ZERO
37.5° 0° 35.6° 27.2° 0° 28.5°
1. SKYRC Angle Gauge SKYRC Angle Gauge 2.
1. Connect the modules.
2. Fix the reference module to the position where the surface of the model aircraft is referenced.
3. Fix the left and right modules on the rudder surface to measure.
Note: The right-angle must face the outside of the rudder surface and be parallel to the edge of
the rudder surface.
Instruction Manual v1.0 SK - 500040
ANGLE GAUGE
Connecting
What is inside the box
Introduction
RC Gears * Please scan the QR code
to download the RC Gears app
from App Store or Google Play!
* Long press the switch
to turn on the modules.
1. Long press to turn on. Enable the Bluetooth on your
smartphone and open the APP. 2. Search to connect
Weight CG
Angle Throw
Unassigned Scale
Unassigned Scale
Unassigned Scale
Searching... Angle-meter
Unassigned Scale
Unassigned Scale
Unassigned Scale
进入
Unassigned Scale
未分配位置
未分配位置
进入
Position Reference
Reference
Left Right
Angle meter Angle meter
Back OK
3. Set up the reference surface, left and right. The corresponding module flashes blue during
the setting.
* The module flashes in blue RED warns that the maximum adjustable angle of the
corresponding wing is greater than the calibration range GREEN indicates that the maximum adjustable angle of the
corresponding wing is within the calibration range
Name Model one Elevator Reference: sensor - relative Angle Set angle Name Model one Elevator Reference: sensor - relative Angle Set angle
Reference angle Right angleLeft angle Reference angle Right angleLeft angle
ZERO
SKYRC Angle Gauge Instruction Manual SKYRC Angle Gauge Instruction Manual
3. SKYRC Angle Gauge SKYRC Angle Gauge 4.
Measure Throw
1. Connect the modules, and choose Throw to enter the page.
2. Fix the reference module to the position where the surface of the model aircraft is referenced
3. Fix the left and right modules on the rudder surface to measure.
Note: The right-angle must face the outside of the rudder surface and be parallel to the edge of
the rudder surface.
4. Set the throw, measure the width of the rudder surface, and input the width and throw in reference
to the model aircraft manual.
5. Set the throw, measure the width of the rudder surface, and input the width and throw in
reference to the model aircraft manual.
ZERO
Left throw
0mm 左侧行程
0.4mm
Aileron width 30 mm
Up aileron 10 mm
Down aileron 10 mm
Elavator width 30 mm
Up elevator 10 mm
Down Elevator 10 mm
Flap width 30 mm
Up flap 10 mm
Name Model one Elevator Reference: sensor - relative Throw Set throw
ZERO
Left throw
16.5mm Right throw
17.2mm
Name Model one Elevator Reference: sensor - relative Throw Set throw
We guarantee this product to be free of manufacturing and assembly defects for a period of one year from the time
of purchase. The warranty only applies to material or operational defects, which are present at the time of purchase.
During that period, we will repair or replace free of service charge for products deemed defective due to those
causes. This warranty is not valid for any damage or subsequent damage arising as a result of misuse, modifica-
tion or as a result of failure to observe the procedures outlined in this manual.
Note:
The warranty service is valid in China only.
If you need warranty service overseas, please contact your dealer in the first instance, who is responsible for
processing guarantee claims overseas. Due to high shipping cost, complicated custom clearance procedures to
send back to China. Please understand SkyRC can't provide warranty service to overseas end user directly.
If you have any questions which are not mentioned in the manual, please feel free to send email to info@skyrc.com
1.
2.
3.
WARRANTY AND SERVICE
2021.05
7504-1490-01
Working Voltage: 3.4-4.2V
Working Current: <10mA
Interface: Type C
Input Voltage: 5V
Input Current: 200-300mA
Low-voltage Protection:
<3.4V (Flashes Red)
Measuring Accuracy: ±2O
Throw Angle: ±0.1mm
Working Temperature: 0OC-40OC
Working Humidity:
5%-90% (No Condensation)
Storage Temperature: -10OC-50OC
Storage Humidity:
1%-75% (No Condensation)
Size: 48.1*25.6*12.6mm
Weight: ≈25g
RED warns that the maximum throw angle of the correspond-
ing wing is greater than the calibration range GREEN indicates that the maximum throw angle of the
corresponding wing is within the calibration range
Constant Blue
Flashing Blue
App is connected and working
Standby, waiting to be connected
Flashing Red Charging
LED Indicator
Name Model one Elevator Reference: sensor - relative Throw Set throw
ZERO
Left throw
16.5mm Right throw
17.2mm
Specifications

Other Skyrc Measuring Instrument manuals

Skyrc NC2500 Pro User manual

Skyrc

Skyrc NC2500 Pro User manual

Skyrc BD350 User manual

Skyrc

Skyrc BD350 User manual

Skyrc Micro Digital Pitch Gauge User manual

Skyrc

Skyrc Micro Digital Pitch Gauge User manual

Skyrc WM-010 User manual

Skyrc

Skyrc WM-010 User manual

Skyrc SK-500026 User manual

Skyrc

Skyrc SK-500026 User manual

Skyrc GSM-010 User manual

Skyrc

Skyrc GSM-010 User manual

Skyrc CTG-015 User manual

Skyrc

Skyrc CTG-015 User manual

Popular Measuring Instrument manuals by other brands

Opsytec UVpad E manual

Opsytec

Opsytec UVpad E manual

RLE Technologies WiNG-MGR v2 user guide

RLE Technologies

RLE Technologies WiNG-MGR v2 user guide

Flytec Element Track quick guide

Flytec

Flytec Element Track quick guide

Somogyi home EM 03 Instructions for use

Somogyi

Somogyi home EM 03 Instructions for use

Thermo Scientific Orion Star A212 reference guide

Thermo Scientific

Thermo Scientific Orion Star A212 reference guide

Hanna Instruments Checker HI717 instruction manual

Hanna Instruments

Hanna Instruments Checker HI717 instruction manual

Axis S3016 installation guide

Axis

Axis S3016 installation guide

AEMC instruments Measure Up PowerPad III quick start guide

AEMC instruments

AEMC instruments Measure Up PowerPad III quick start guide

Avtech Room Alert 4E User guide and reference manual

Avtech

Avtech Room Alert 4E User guide and reference manual

Seitron S500 Use and maintenance

Seitron

Seitron S500 Use and maintenance

Quantum CALCU-LIGHT X operating instructions

Quantum

Quantum CALCU-LIGHT X operating instructions

Crowcon Gas-Pro quick start guide

Crowcon

Crowcon Gas-Pro quick start guide

Prexiso PR500HVG manual

Prexiso

Prexiso PR500HVG manual

TESTO 545 instruction manual

TESTO

TESTO 545 instruction manual

Wilcoxon MachineryMate 800-IS operating guide

Wilcoxon

Wilcoxon MachineryMate 800-IS operating guide

Pentax MOVIE 8 PV-C800A instruction manual

Pentax

Pentax MOVIE 8 PV-C800A instruction manual

Greenlee HCO-100 instruction manual

Greenlee

Greenlee HCO-100 instruction manual

sauter SP 200K instruction manual

sauter

sauter SP 200K instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.