manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Slant/Fin
  6. •
  7. Boiler
  8. •
  9. Slant/Fin VICTORY II VHS Series User manual

Slant/Fin VICTORY II VHS Series User manual

SENTRY
®
LOWER PROFILE MAKES
PROBLEM INSTALLATIONS EASY
High efficiency, cast-iron gas boiler
S
ENTR
Y
®
High efficiency, cast-iron gas boiler
A smarter choice for informed
The boiler you choose for your home now will
affect your family’s comfort--and pocketbook--for
many years to come. Sentry boilers provide a
blend of efficiency and reliability that will keep your
home comfortably warm and your fuel costs low
year after year. A new Sentry boiler can save up to
30% or more on fuel bills compared to a typical old
boiler operating at 60% efficiency.
• AGA input:
“S”models 34,000 to 150,000 Btu/hr
“SX”models 150,000 to 210,000 Btu/hr
• Low clearance
• Standing pilot or intermittent ignition.
• Saves energy. AFUE to 84.4%
Sentry is ideal for a wide variety of gas boiler
requirements, as a replacement or for new
installations. Its advanced design provides
years of trouble-free, high efficiency operation
while providing easy installation, even in sites
with low chimney connections or low over-
head clearance.
Sentry is a reliable natural draft boiler. Many boil-
ers resort to pulsing or condensing technologies,
copper fin-tubes and thermal bypass valves to
attain acceptable efficiency. Sentry achieves high
efficiency with fewer components, so there's less
chance of part failure or losing your heat. Sentry’s
efficiency to 84.4% is among the highest in the
industry. Sentry’s heat exchanger is made of quali-
ty cast-iron and assembled with durable metal
push nipples. It's so reliable it comes with a lifetime
limited warranty. Sentry boilers respond quickly to
your thermostat’s call for heat, sending heat within
moments to radiators throughout your home.
Low profile makes problem installations easy.
All “S” and “SX” models permit installation in sites with low
chimney breeching or low overhead clearance.
The Sentry boiler fits into replacement sites with low
chimney breeching or low overhead clearance.
The Sentry “S” models include an integral draft diverter
and do not require a draft hood. They fit into replacement
sites with overhead clearance or chimney breeching as
low as 381⁄2in. above the floor.* This is nearly a foot and a
half less clearance than required by typical natural draft
boilers. The rear flue outlet on “S” models keeps the vent
pipe out of the way of water and gas piping. Installation is
faster and trimmer. “SX” models utilize an external draft
hood.
The computer-aided design of Sentry’s venting system
enables “S” and “SX” models to perform effectively under a
wide range of draft conditions. Sentry is one of the indus-
try’s most versatile and durable high efficiency boilers.
*See installation instructions for specific applications and clearances.
LOW-PROFILE VERSATILITY.
NATURAL DRAFT RELIABILITY
“S” model with integral
draft diverter “SX” model with external
draft hood
d homeowners.
Natural draft reliability and high
efficiency too. Choose intermittent
ignition or standing pilot.
Enjoy the easy installation and reliable operation
that natural draft design provides, plus high
efficiency too. With intermittent pilot ignition,
Sentry AFUE's range from 83.1% to 84.4%.
Standing pilot AFUE to 83% —
highest in the industry!
Sentry standing pilot models are the most efficient
in the industry, according to the I=B=R Boiler
Ratings directory. Now, with AFUE’s to 83%,
you can enjoy standing pilot reliability and high
efficiency too!
All models include an automatic vent damper.
Computer-aided design.
Highest quality manufacturing.
Superior components.
Advanced design heat exchanger with metal push
nipples provides superior performance, longer life.
Computer-aided design of heat exchanger maximizes transfer of
heat from the gas flame to the boiler water which then flows into
your heating system. Superior heat transfer properties permit use of
smaller, compact cast-iron heat exchanger sections. The flue pas-
sage design, thermal pin pattern and consistent wall thickness
ensure uniform heat transfer with less thermal strain and metal
fatigue.
Metal push nipples avoid leaks.
Slant/Fin uses only metal push nipples that expand and contract
with the individual boiler sections that they connect. In many ordi-
nary boilers, flimsy rubber or plastic gaskets are substituted for
metal push nipples and are subject to deterioration and leaks.
Reliable heavy-duty vent damper saves energy.
The motorized Slant/Fin vent damper increases efficiency of the
boiler by reducing standby losses. Motor closes the chimney vent
when the burner is off, fully opens it in anticipation of combustion.
May be installed horizontally or vertically to accommodate varying
vent pipe requirements. Heavy-duty collar maintains dimensional
stability for smooth operation.
Vent damper shown on “S” model.
Insulated base
Base is constructed of heavy gauge aluminized steel. Thick refracto-
ry insulation surrounds combustion chamber, minimizing standby
losses and increasing efficiency.
Long-life burners
Quiet, light and easy to install or remove. Same stainless steel
burners serve natural or propane gas. Special port construction will
not permit flame to “lift” or flash back. Sentry burners last longer too
because of low operating temperature. Input per burner is only
15,000 Btu/hr.
S
ENTR
Y
®
High efficiency, cast-iron gas boiler
Cast-iron
heat
exchanger
Thermal pins
Metal
push nipples
Insulated
base
Integral
draft hood
(“S” models only)
Motorized
heavy-duty
vent damper
Insulated
jacket
Brand
name
controls
Long life
burners
Gas valve
Circulator pump
Relief valve
Blocked vent
safety switch
Not visible in photo
Pressure
temperature
gauge
Rollout safety switch
Highest standing
pilot AFUE
in the
industry.
There are 3 Sentry SX models
ranging in size from 150 to 210 MBh,
A.G.A. input. SX models include an external draft hood.
Zone your heating system for even greater fuel savings. By dividing your home into
separate heating zones, you can save energy by heating only those areas you’re
using. Depending on your existing piping arrangement, it may be quite
simple to zone your system.
Make your house a more comfortable home
With a Sentry boiler at the heart of your heating system, you can enjoy deluxe heating comfort
all around your home. A Sentry boiler can be installed to provide heating energy for any or all
these hydronic heating systems:
More hot water for your kitchen,
bath and laundry
For a large reserve of hot water for your family all year
long, your installer can provide a Slant/Fin Model WH
indirect-fired water heater. It’s connected just like a
heating zone to the Sentry boiler and will store between
30 and 80 gallons of hot water. Tapping the boiler’s
heating capacity, the Slant/Fin water heater offers far
better efficiency, faster recovery and longer life than an
ordinary direct-fired water heater. The 40 gallon model,
for instance, delivers 195 gallons of hot water per hour!
1
2
4
5
6
Zone heating with Slant/Fin hot water baseboard and individual room temperature controls.
Warm floors with Terra Therma radiant heating by Slant/Fin.
Slant/Fin hot water fan-convection heaters under cabinets or stairs.
Hot water with a high volume Slant/Fin indirect-fired water heater.
Snow melting for driveway and sidewalks with Terra Therma radiant tubing.
Pool or spa water heating with a Slant/Fin boiler and external heat exchanger.
1
1
11
1
1
1
1
1
1
2
2
2
2
3
3
4
5
5
6
6
3
S-34 34,000 29,000 25,000 167 80.4 84.0 81⁄8145⁄84_ _
S-60 60,000 51,000 44,000 293 81.6 84.4 111⁄8175⁄84_ _
S-90 90,000 76,000 66,000 440 82.3 84.2 141⁄8205⁄85_ _
S-120 120,000 101,000 88,000 587 83.0 84.1 171⁄8235⁄86_ _
S-150 150,000 125,000 109,000 727 82.4 83.4 201⁄8265⁄87_ _
SX-150 150,000 126,000 110,000 733 82.1 83.2 201⁄8265⁄8_647
SX-180 180,000 151,000 131,000 873 82.1 83.1 231⁄8295⁄8_748
3⁄16
SX-210 210,000 175,000 152,000 1013 82.0 83.1 261⁄8325⁄8_748
3⁄16
MODEL
NUMBER †
A.G.A.
INPUT
(Btuh)
D.O.E.
CAPACITY
(Btuh)
NET
I=B=R
RATING
WATER
(Btuh) * WATER
(Sq.Ft.) STANDING
PILOT
INTERMITTENT
IGNITION
RATINGS FOR SENTRY BOILERS--NATURAL AND L.P. GAS
EFFICIENCY
(A.F.U.E.%)
DIMENSIONS-Inches
ABD
C-VENT DIAMETER
* Net ratings are based on a piping and pick-up allowance of 1.15. Slant/Fin
should be consulted before selecting a boiler for installation having unusual
piping and pick-up requirements. Ratings must be reduced by 4% at 2,000
feet elevation and an additional 4% for every additional 1,000 feet elevation
over 2,000 feet.
†Type of gas: after model number, specify gas by name “Natural” or
“Propane”.
Note: All Sentry boilers are tested and rated for capacity under the U.S.
Dept. of Energy (D.O.E.) Test Procedure for boilers.
C
193/4"
193/4"
193/4"
11/2" Supply
11/2"
Supply
11/2" Supply
3/4" Drain
3/4"Drain
3/4" Drain
3/4" to air eliminating
system (by others)
3/4" to air eliminating
system (by others)
3/4" to air eliminating
system (by others)
Rollout Safety
Switch (behind
front panel)
Rollout Safety
Switch (behind
front panel)
Rollout Safety
Switch (behind
front panel)
Vent Damper*
Vent Damper*
Vent Damper*
Vent Damper*
287/16"
287/16"
327/16"
6
1/2"
Pressure/Temp.
Gauge
Pressure/Temp.
Gauge High Limit.
Control
Ignition
Control
High Limit
Control
Ignition
Control
High Limit
Control
Ignition
Control
Blocked Vent
Safety Switch
Blocked Vent
Safety Switch
Blocked Vent
Safety Switch
Supply Piping
(by others)
Supply Piping
(by others)
Combination
Gas Valve
(gas tapping 1/2")
Combination
Gas Valve
(gas tapping 1/2")
Combination
Gas Valve
(gas tapping 1/2")
Ground
Joint Union
Ground
Joint Union
Ground
Joint Union
Circulator:
1/4" Circ. Flange
1
1/2" Return Tapping
Circulator:
1/4" Circ. Flange
1
1/2" Return Tapping
Circulator:
1/4" Circ. Flange
1
1/2" Return Tapping
Sediment Trap
(required)

Sediment Trap
(required)

Sediment Trap
(required)

(Dotted piping
by others.)

(Dotted piping
by others.)

(Dotted piping
by others.)

Integral 
Draft
Diverter
Pressure/Temp.
Gauge
C
AB
C
A
A
B
B
C
D
INTEGRAL
DRAFT
DIVERTER
EXTERNAL
DRAFT
HOOD
Dimensions
MODELS S-60
to S-150
Dimensions
MODEL S-34
Dimensions
MODELS SX-150
to SX-210
LEFT END VIEW FRONT VIEW RIGHT END VIEW
LEFT END VIEW FRONT VIEW RIGHT END VIEW
LEFT END VIEW FRONT VIEW RIGHT END VIEW
*Vent damper may be installed horizontally on all models with use of a common vent elbow.
S
ENTR
Y
®
High efficiency, cast-iron gas boiler
Engineered for comfort,
safety and reliability.
Millions of homes are
equipped with Slant/Fin
hydronic heating.
Lower profile,
higher efficiency
SLANT/FIN CORPORATION, Greenvale, NY 11548 • Phone: (516) 484-2600
Fax: (516) 484-5921 • In Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario
www.slantfin.com ©Slant/Fin Corp. 2002. Printed in the U.S.A. 502 Publication No. S-10

Other manuals for VICTORY II VHS Series

72

Other Slant/Fin Boiler manuals

Slant/Fin VICTORY II VHS Series User manual

Slant/Fin

Slant/Fin VICTORY II VHS Series User manual

Slant/Fin VICTORY II VHS Series User manual

Slant/Fin

Slant/Fin VICTORY II VHS Series User manual

Slant/Fin VSPH-120 Application guide

Slant/Fin

Slant/Fin VSPH-120 Application guide

Slant/Fin VICTORY II VHS Series User manual

Slant/Fin

Slant/Fin VICTORY II VHS Series User manual

Slant/Fin LIBERTY II LD-20 User manual

Slant/Fin

Slant/Fin LIBERTY II LD-20 User manual

Slant/Fin Q3-4 Owner's manual

Slant/Fin

Slant/Fin Q3-4 Owner's manual

Slant/Fin VICTORY II VHS Series User manual

Slant/Fin

Slant/Fin VICTORY II VHS Series User manual

Slant/Fin EUTECTIC EC-10 Series User manual

Slant/Fin

Slant/Fin EUTECTIC EC-10 Series User manual

Slant/Fin B-120A User manual

Slant/Fin

Slant/Fin B-120A User manual

Slant/Fin VSL-160B User manual

Slant/Fin

Slant/Fin VSL-160B User manual

Slant/Fin VSPH-180 User manual

Slant/Fin

Slant/Fin VSPH-180 User manual

Slant/Fin VICTORY II VHS Series User instructions

Slant/Fin

Slant/Fin VICTORY II VHS Series User instructions

Slant/Fin VICTORY II VHS Series Guide

Slant/Fin

Slant/Fin VICTORY II VHS Series Guide

Slant/Fin LX-90 User manual

Slant/Fin

Slant/Fin LX-90 User manual

Slant/Fin VICTORY II VHS Series Guide

Slant/Fin

Slant/Fin VICTORY II VHS Series Guide

Slant/Fin Malibu User manual

Slant/Fin

Slant/Fin Malibu User manual

Slant/Fin VICTORY II VHS Series User manual

Slant/Fin

Slant/Fin VICTORY II VHS Series User manual

Slant/Fin SE-70 User manual

Slant/Fin

Slant/Fin SE-70 User manual

Slant/Fin GG-100H User manual

Slant/Fin

Slant/Fin GG-100H User manual

Slant/Fin VICTORY II User manual

Slant/Fin

Slant/Fin VICTORY II User manual

Slant/Fin VICTORY II VHS Series User manual

Slant/Fin

Slant/Fin VICTORY II VHS Series User manual

Slant/Fin LX-120CB Guide

Slant/Fin

Slant/Fin LX-120CB Guide

Slant/Fin victory II VH series User manual

Slant/Fin

Slant/Fin victory II VH series User manual

Slant/Fin VICTORY II VHS Series User manual

Slant/Fin

Slant/Fin VICTORY II VHS Series User manual

Popular Boiler manuals by other brands

Fondital Tahiti Condensing 24 kW Combi (KC) Installation, use and maintenance

Fondital

Fondital Tahiti Condensing 24 kW Combi (KC) Installation, use and maintenance

C&M Britony FlexiFlue Instructions for use

C&M

C&M Britony FlexiFlue Instructions for use

Viessmann Vitocell 140-E Installation and service instructions

Viessmann

Viessmann Vitocell 140-E Installation and service instructions

Immergas INOXSTOR 200 V2 manual

Immergas

Immergas INOXSTOR 200 V2 manual

Nobis POLYGON 25 Instructions for installation, use and maintenance manual

Nobis

Nobis POLYGON 25 Instructions for installation, use and maintenance manual

NBE BRAWN MIXER BDAQC Series Operation and maintenance manual

NBE

NBE BRAWN MIXER BDAQC Series Operation and maintenance manual

Energie ECOTOP 200i Technical manual

Energie

Energie ECOTOP 200i Technical manual

E.C.A. CO 24 BB Installation and user's operating instructions

E.C.A.

E.C.A. CO 24 BB Installation and user's operating instructions

Trianco TRG 45 User, installation, commissioning & servicing instructions

Trianco

Trianco TRG 45 User, installation, commissioning & servicing instructions

Worcester Greenstar 12i System ErP user manual

Worcester

Worcester Greenstar 12i System ErP user manual

Strom Combi E-Boiler Series installation guide

Strom

Strom Combi E-Boiler Series installation guide

Viessmann VITOCELL 100-U installation instructions

Viessmann

Viessmann VITOCELL 100-U installation instructions

Mark Climate POWERFLEX Technical manual

Mark Climate

Mark Climate POWERFLEX Technical manual

Viessmann VITOFLEX 300-RF Service and maintenance instructions

Viessmann

Viessmann VITOFLEX 300-RF Service and maintenance instructions

FireBird P90 Technical manual

FireBird

FireBird P90 Technical manual

Watts Aerco Benchmark OMM-0117 Operation and maintenance manual

Watts

Watts Aerco Benchmark OMM-0117 Operation and maintenance manual

PB Heat PSC-06 Installation, operation & maintenance manual

PB Heat

PB Heat PSC-06 Installation, operation & maintenance manual

Ideal Boilers icos system m3080 Installation and servicing

Ideal Boilers

Ideal Boilers icos system m3080 Installation and servicing

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.