Sloan EFX-8 SERIES Use and care manual

Repair Parts and Maintenance Guide
141
Faucets and
Soap Dispensers
The information contained in this document is subject to change without notice.
BASYS®
Infrared Sensor Activated
PARTS LIST—BASYS FAUCETS
Item
No. Code No. Part No. Description
1. —— Wall Mount Faucet Assembly
2. 3324104 EFX-1002-A 0.5 gpm/1.9 Lpm Multi-Lam Spray Head (includes
insert, o-ring, 2.5 mm allen key, and removal tool)
3324103 EFX-1001-A 1.5 gpm/5.7 Lpm Aerated Stream Insert (includes
insert, o-ring, 2.5 mm allen key, and removal tool)
3324102 EFX-1000-A 1.5 gpm/5.7 Lpm Laminar Stream Insert (includes
insert, o-ring, 2.5 mm allen key, and removal tool)
3. 3324162 EFX-1011-A 0.5 gpm/1.9 Lpm Solenoid Valve Caddy Assembly
– Wall (Green)‡
3324163 EFX-1012-A 1.5 gpm/5.7 Lpm Solenoid Valve Caddy Assembly
– Wall (Blue) ‡
4. 0324019 EFX-19 Strainer (Filter)
5. —EFX-1013-A Mounting Assembly
6A. 3324160 EFX-1009-A Bowed Crown Assembly
6B. 3324138 EFX-1010-A Solar Crown Assembly
6C. 3324139 EFX-1018-A Solar Crown with LCD Assembly
7. —— CR-P2 Lithium Battery
8. 3326009 MIX-60-A Mechanical, Below Deck Mixing Valve
9. 0326045 MIX-135-A Thermostatic, Below Deck Mixing Valve
10. 3365461 ETF-617-A Bak-Chek Tee Assembly
11. 0335023 EAF-23-A Splitter
12. 0335024 EAF-24-A 11-13/16” (300 mm) Extension Cable
0335025 EAF-25-A 47-1/4” (1200 mm) Extension Cable
0335015 EAF-17-A 126” (3200 mm) Extension Cable
13. 0335009 EAF-11 Plug-in Adapter (US)
0335041 EAF-41 Plug-in Adapter (EU)
0335039 EAF-39 Plug-in Adapter (UK)
0335037 EAF-37 Box Mount Adapter
14. 3324165 EFX-1014-A Wall Flange
15. —— Purge Tool
NOTE: If changing ow rate caddy and spray insert must be changed in conjunction.
† Single Supply faucets include Bak-Chek®
— in Item No. column = Not shown in illustration
— in Code No. and Part No. column = Not sold separately
‡ Old style / T-shaped contact.
New style / Plug contact
6A 6B 6C
14
7
4
1
5
8
3
9
10
13
15
12
11
2
Electrical Connection for up to Six (6) Faucets Using One (1) Adapter
EFX-8XX SERIES
NOTE: HARDWIRE FAUCETS SUPPLIED WITH ONE (1) 47” (1.2 m) EXTENSION CABLE.
NOTE: EXTENSION CABLES AVAILABLE SEPARATELY.
NOTE: USE ONLY SLOAN SUPPLIED POLARIZED AND KEYED CABLE ASSEMBLIES.
IMPORTANT: CUTTING AND SPLICING WIRES WILL VOID WARRANTY.
SPLITTER AND
EXTENSION CABLE
6 VDC
PLUG-IN
ADAPTER
CABLE
BEHIND
THE WALL
CABLE
BEHIND
THE WALL
CABLE
BEHIND
THE WALL
SPLITTER AND
EXTENSION CABLE
TO ADDITIONAL
FAUCETS (6 MAX)

Repair Parts and Maintenance Guide
142 The information contained in this document is subject to change without notice.
Faucets and
Soap Dispensers
BASYS®
Infrared Sensor Activated
As the user’s hands enter the beam’s effective range, the beam is reected
back into the sensor receiver and activates the solenoid valve allowing water
to ow from the faucet. Water will ow until the hands are removed or until
the faucet reaches its automatic time out limit setting.
OPERATION
This feature will operate the faucet
every 12 or 24 hours since last
use, if not used to prevent stagnant
water conditions.
Default purge duration is two
minutes.
Consult factory regarding other
timing options.
IR activation (see above). Cover IR
clic approximately 24 sec. (ignore
LED indications during this period).
Release when requested program
is reached. (See diagram to right).
Programming mode will time out
after 2 minutes if no changes are
made.
12/24 LINE PURGE FEATURE
Activate 12HR
Deactivate
Activate 24HR
1x 24 sec
...1x
...2x
...3x
+ ...
Activate 12HR
Deactivate
Activate 24HR
1x 24 sec
...1x
...2x
...3x
+ ...
Steps to Default IR
Function Activate Function Setting Clic
IR Activation Cover IR clic approximately for 2 sec. –– ––
until LED will ash GREEN 1x - then remove
nger from IR clic (Active for 5 sec.)
Cleaning IR activation; Cover IR clic 2x - conrmation 2 min. ––
Mode of the function is active by a couple ashes
by the LED; to return to normal operation cover
IR clic 1x or the faucet will automatically return
to normal function after 2 min.
12/24 Line See below. Off Off
Purge 12HR
Feature 24HR
Sensor See next page. 6 1-8
Range
Adjustment
Reset IR activation; Cover IR clic 2x; LED will ash 5x Manually ––
Electronics Cover IR clic 1x for 5 sec. until LED
ashes 4x, then remove nger from IR clic
Wait for 20 sec.
(After 10 sec. water will ow for 6 sec.
and automatically adjust to environment)
Security Off After 90 seconds (max) of hand and/or object On ––
within sensor appears permanent, waterow
will stop and will remeasure environment
Please contact factory for more extensive programming options.

Repair Parts and Maintenance Guide
143
Faucets and
Soap Dispensers
The information contained in this document is subject to change without notice.
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
Wait, until LED ashes GREEN.
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
BASYS®
Infrared Sensor Activated
Factory setting is appropriate for the majority of applications and
should not require resetting unless under extreme situations: high
reflection or low light.
IR Activation (see previous page).To enter programming mode place nger
on IR clic for 2 times then remove. Light on side of crown should blink to
indicate programming mode.
SENSOR RANGE ADJUSTMENT BATTERY REPLACEMENT
NOTE: Replace battery when LED1 indicator flashes RED each time
faucet is in use or when faucet stops functioning. LED1 is identified
by the battery symbol.
NOTE: Turning off water is not necessary.
Remove crown by loosening 2 hex screws located on
underside of spout and slide crown down and lift off.
NOTE: Screw is captive within faucet body and will
NOT fall out.
UNLOCK
LOCK
LOCK
RED LED
UNLOCK
UNLOCK
LOCK
LOCK
RED LED
UNLOCK
UNLOCK
LOCK
LOCK
RED LED
UNLOCK
Cover IR clic until LED ashes RED 4 times - hold IR clic on until LED
ashes 1 time to 8 times from minimum to maximum range. See diagram
below. Release when requested range is reached.
Remove red cover over the battery. Remove battery holder from the faucet
body. Replace battery in the holder. Holder drops into the faucet body.
Place the red cover over the battery.
Slide on crown and secure in 2 places.

Repair Parts and Maintenance Guide
144 The information contained in this document is subject to change without notice.
Faucets and
Soap Dispensers
BASYS®
Infrared Sensor Activated
NOTE: Turning off water is not necessary, due to integrated automatic stop
valve.
Rotate solenoid assembly counter-
clockwise through a 45º angle.
Pull solenoid caddy from faucet.
NOTE: Strainer can be removed,
cleaned and replaced at this time.
Insert new solenoid caddy at a
45° angle.
Remove crown by loosening hex
screw located on underside of spout
and slide crown down and lift off.
NOTE: Screw is captive within
faucet body and will NOT fall out.
REPLACING THE SOLENOID STRAINER (FILTER)
UNLOCK
LOCK
UNLOCK
LOCK
UNLOCK
LOCK
UNLOCK
LOCK
Rotate solenoid caddy clockwise to
align with arrow, locking the unit
and opening water path.
Slide on crown and secure in
2 places.
NOTE: Turning off water is not necessary, due to integrated automatic stop
valve.
Retrieve spray removal tool located
near the spray insert.
Insert spray removal tool into spray
slot by sliding hook end of key
between faucet spout and insert.
Pull insert out of faucet once
hooked.
Remove crown by loosening hex
screw located on underside of spout
and slide crown down and lift off.
NOTE: Screw is captive within
faucet body and will NOT fall out.
REPLACE SPRAY INSERT
Install new insert.
NOTE: If changing to a different
ow rate solenoid caddy must be
changed in conjunction.
Return spray removal tool to storage
location.
NOTE: This can only be done once
spray head is installed. This will lock
the spray head in place.
NOTE: If spray head is inserted
incorrectly – key will not lock in
properly. Turn faucet on to push
insert out and re-install.
Slide on crown and secure.

Repair Parts and Maintenance Guide
145
Faucets and
Soap Dispensers
The information contained in this document is subject to change without notice.
BASYS®
Infrared Sensor Activated
Remove crown by loosening hex
screw located on underside of spout
and slide crown down and lift off.
NOTE: Screw is captive within
faucet body and will NOT fall out.
UPGRADE FAUCET FUNCTIONALITY
LED DISPLAY DIAGNOSTIC CODES
Place new crown on faucet by sliding
onto spout and tightening hex screw
on underside of spout.
NOTE: All electronics are fully
encapsulated in the crown
and thus protected from the
environment and easy to replace
or upgrade.
RED GREEN
RED GREEN
RED
RED
RED
RED
RED
GREEN
GREEN
GREEN
RED
RED
RED
RED LED1
GREEN LED2
RED LED3
Function LED1 LED2 LED3 Description 1 Description 2
Start Up Boot LED1 and LED2 alternate blinking Fast Toggle
Battery Check after Start Up LED1 on for 2 sec, if battery greater than 3.5V
Line Power Check after Start Up LED3 on for 2 sec, if line power greater than 3.5V
IR Adjust Process LED1 blinking while IR adjusts Few seconds
IR Adjust IR LED2 on for 2 sec, if adjustment OK
Battery Low LED1 blinks 3x, if battery is less than warning level Only while in detection mode
Battery Empty LED1 double ashes 3x, if battery is
less than empty level Only while in detection mode
Valve Error
LED3 double ashes 3x, if valve
current error; ash after the 3rd error,
off after the 3rd good operation
Flashes after the 3rd error, off
after the 3rd good operation
IR Activation LED2 on for 2 sec, if IR-click has been activated After 5 sec. automatically back to
operating mode
Cleaning Mode LED1 4-in-1 ash, if cleaning mode is activated During “Cleaning Mode” is activated
Permanent 4-in-1 ashes
COLOR LEDs BLINKING
COLOR LEDs ON
UNLOCK
LOCK
UNLOCK
LOCK

Repair Parts and Maintenance Guide
146
Faucets and
Soap Dispensers
The information contained in this document is subject to change without notice.
BASYS®
Infrared Sensor Activated
1. RED LED in spout DOES NOT blink 2 seconds after battery
installation.
A. Battery placement incorrect or batteries have been discharged.
Ensure batteries are installed properly. Check the orientation of each
battery matches the positive (+) and negative (–) symbols shown on
the battery compartment.
2. Faucet DOES NOT function.
A. Adhesive packaging label afxed over sensor eye.
Remove adhesive label from sensor eye.
3. Faucet delivers water in an uncontrolled manner.
A. Faucet is not working properly.
B. Clean sensor window; if problem persists contact Sloan Technical
Support (see below).
4. Faucet DOES NOT deliver any water when sensor is activated.
INDICATOR: Solenoid valve produces an audible “CLICK”.
A. Water supply stop(s) closed.
Open water supply stop(s).
B. Strainer is clogged.
Remove, clean, and reinstall strainer. Replace strainer (lter), if needed
(refer to page 139).
INDICATOR: Solenoid valve DOES NOT produce an audible “CLICK”.
A. Batteries low (battery-powered models).
Replace batteries (refer to battery replacement on page 136).
B. Power failure (hardwire models).
Check power supply.
5. Faucet delivers only a slow flow or dribble when sensor is
activated.
A. Water supply stop(s) are partially closed.
Completely open water supply stop(s).
6. Faucet DOES NOT stop delivering water or continues to drip after
user is no longer detected.
A. Faucet is not working properly.
Clean sensor window; if problem persists contact Sloan Technical
Support (see below).
7. LED indicator blinks RED when faucet is in use.
A. Batteries low (battery-powered models).
Replace batteries (refer to battery replacement on page 136).
8. The water temperature is too hot or too cold on a faucet
connected to hot and cold water supply lines.
A. Supply stops are not adjusted properly.
Adjust supply stops.
B. For models with integral side mixing valve–mixing valve is set
improperly for the water temperature desired.
Rotate mixing valve handle clockwise to decrease water temperature or
counterclockwise to increase water temperature.
C. Inadequate hot water supply.
Adjust supply stops.
CARE AND CLEANING
DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to
clean faucets that may dull the luster and attack
the chrome or special decorative nishes. Use
ONLY mild soap and water, then wipe dry with
clean cloth or towel.
While cleaning the bathroom sink, protect the
faucet from any splattering of cleaner. Acids and
cleaning uids will discolor or remove chrome
plating.
When assistance is required, please contact
Sloan Technical Support at: 1-888-SLOAN-14
(1-888-756-2614).
TROUBLESHOOTING GUIDE